28
3M™ MicroTouch™ Controller RX142 Reference Guide
3M Touch Systems, Inc. Proprietary Information
Technical Specifications
Physical Dimensions
2.74 in. x 1.49 in. x 0.45 in. (69.6 mm x 37.8 mm x 11.4 mm)
Board Level Functions
Power
5 VDC (16 mA typical, 27 mA with touch);
±
5% regulation
12 VDC (19 mA typical, 30 mA with touch);
±
5% regulation
50
mV
pp
maximum ripple and noise
Regulatory Requirements
CE
Compliant
Radiated Emissions – EN 55022:1998
Class B
Compliant
AC Mains Conducted Emissions – EN 55022:1998
Class B
Compliant
Telco Lines Conducted Emissions
N/A
N/A
FCC Class B / CISPR22 Class B
Class B
Compliant
VCCI Class B ITE Emissions (Japan)
Class B
Compliant
AS/NZS 3548:1995/CISPR 22 Class B ITE Emissions (Aus.)Class B
Compliant
RFI – EN 61000-4-3 / ENV 50140
Class A
Compliant
CRFI – EN 61000-4-6
N/A
Cable < 3 meters long
N/A
EFT (Burst Immunity) – EN 61000-4-4
Class B
Compliant
ESD Susceptibility – IEC 61000-4-2
Class 1
Compliant
Surge – EN 61000-4-5
Class B
Compliant
Harmonics – EN 61000-3-2
Class A
Compliant
Flicker – EN 61000-3-3
Compliant
Power Frequency Magnetic Field – EN 61000-4-8
Class A
Compliant
Voltage Dips – EN 61000-4-11
Class B < 5% V
Class C < 70% V
Compliant
Voltage Interruptions – EN 61000-4-11
Class C
Compliant
UL/cUL Compliant
Ambient Operating and Storage Environmental Conditions (All Humidity is
Non-Condensing)
Operating Temperature Range
0
°
C to +65
°
C
Operating Humidity Range
< 36° C 0-95% RH
≥
36
°
C see Figure 1 below
Storage Temperature Range
- 20
°
C to +75
°
C
Storage Humidity Range
< 36°C 0-80% RH
≥
36
°
C see Figure 1 below