Plumbing Connections 

  1.  Install feed water line to marked “Inlet” 1/2” NPT inlet connection.

  2.  Install RO water line from marked “Tank Outlet” to pressure tank (Sold Separately). Assemble and install pressure tank fi ttings per 
 

instructions provided with tank.

3.  Install RO water line from marked “Equipment Outlet” to the foodservice equipment.  Installation of a post fi lter is required downstream of the 

RO system (Required/Sold Separately).   

4.  Install drain line from marked “Drain Outlet” to the drain . An approved air gap must exist between the RO system reject drain line and the 

drain opening to comply with state and local plumbing codes.

5.  Install 1/2" Bypass line as shown on Figure 1-Plumbing Diagram (if required).

6.  Check air pressure on the pressure tank using the valve on the tank. With the tank empty, the pressure should read between 7-18  psi (48-124 

kPa). Adjust as required. 

7.   Plumbing connections for the ScaleGard

TM

 HP reverse osmosis system are now complete. 

Install cartridge per instructions below.  

 

Pre-Filter and Post Filter Cartridge (blue label) Installation:

1.  Remove red sanitary cap from new cartridge. Ensure o-rings are seated into their grooves and lubricate with water. Install with a quarter turn 

to the right until cartridge come to a complete stop. NOTE: Cartridges are keyed to fi t in proper location only.  

Figure 3 - Installation Instructions

Step 1: Remove the plug from the 1/4" fi tting at the bottom of the RO cartridge by pushing in the collet and pulling out the plug.

Step 2: Remove the Twin fl ow control assembly from the packaging.

Step 3: Firmly push the short tubing on one end of the twin fl ow control into the John Guest 1/4” NPT fi tting at bottom of the RO cartridge.

Step 4: Push the reject tubing into the fi tting in the twin fl ow control assembly.

Step 5: Operating pressure will need to be reset (See Operating Pressure Adjustment instructions on page 14).

 HFRO 33% Recovery Kit

 HFRO 50% Recovery

(Use only if recommended by installer)

Содержание ScaleGard HP

Страница 1: ...manual with owner operator Owner Operator Please retain for operation and future instructions 3M Water Filtration Products Installation and Operation Instructions for ScaleGardTM HP Reverse Osmosis S...

Страница 2: ...aution Statements 4 Parts List 5 Feedwater Requirements 6 Other Requirements 6 Equipment Set Up and Installation 7 System Start Up 10 Routine Maintenance 15 16 Troubleshooting Guide 17 Product Replace...

Страница 3: ...is higher than 80 psi install a pressure reducing valve before installing the water filtration system An approved post filter and tank must be used with the RO system To reduce the risk associated wit...

Страница 4: ...T install an appropriate pressure relief valve Pressure relief valve must be maintained and inspected every 6 months Contact a plumbing professional if you are uncertain how select install maintain a...

Страница 5: ...ilter and RO with UK plug 6239304 220 240VAC w out Pre filter and RO with AU plug HF90 CL RO Pre Filter 1 5613529 HFRO 500 RO membrane 1 5626903 Equipment Components Sold Separately Description Quanti...

Страница 6: ...PN 50 93201 If the particle count is 1000 counts ml for particles less than 2 micron size or turbidity is greater than the recommended 5 ntu limit then it may be required to consider different prefilt...

Страница 7: ...leGard HP reverse osmosis base unit and 0 5 or larger tubing diameter is required to complete installation Figure 1 Plumbing Diagram Bypass Provided by Installer Check Valve Provided by Installer 1 2...

Страница 8: ...with property damage due to water leakage or flooding Mount ScaleGardTM HP base unit in such position as to prevent it from being struck by other items being used in the area of installation Ensure t...

Страница 9: ...Plumbing connections for the ScaleGardTM HP reverse osmosis system are now complete Install cartridge per instructions below Pre Filter and Post Filter Cartridge blue label Installation 1 Remove red s...

Страница 10: ...ee Figure 1 page 7 2 Turn ON the feedwater supply by plugging system into electrical outlet 3 Open Pre Filter flush valve to vent air from system and flush for 10 gallons approximately 5 minutes If er...

Страница 11: ...after the desired TDS value is reached Re adjust and check as needed See Figure 5 item 2 below 4 Lock the blending valve using the lock nut 5 After TDS is set drain RO tank System is now ready for use...

Страница 12: ...BLUE BROWN Step Down Transformer 3 WIRE NUT 8 LEVER NUT 14 11 6 LEVER NUT 5 LEVER NUT 7 LEVER NUT TERMINAL BLOCK Output LED Color Meaning Normal Running Condition PWR Green On when the units power co...

Страница 13: ...bar for 220 240VAC systems the unit is off on full tank 1 Unit will cycle on when tank switch senses 40 psi TOGGLE CYCLE 1 Motor Pump stop 2 2 second delay the inlet solenoid closes 3 1 second delay t...

Страница 14: ...is is normal To reduce the risk associated with property damage due to water leakage or flooding Notice Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if...

Страница 15: ...low their guidelines as you install the water filtration system Your water filtration system will withstand up to 125 pounds per square inch psi water pressure If your water supply pressure is higher...

Страница 16: ...pressure 2 Release tubing 3 Cut off at least 1 4 from end 4 Reattach tubing 5 Confirm connection is leak free Figure 9 How to Use Push in Connectors 4 Remove sanitary cap from new RO membrane cartridg...

Страница 17: ...e Check for 1 feedwater pressure 2 production flow rate 3 drain flow rate before replacing RO membrane Ensure drain line is not kinked or plugged Replace if needed RO membrane fouls high feed water ha...

Страница 18: ...ge Contact Dealer 60 125001 Permeate Solenoid Contact Dealer 85 9274 Shroud Contact Dealer 89 3220101 Pump Head Contact Dealer 89 2302 Pump Motor Contact Dealer 5613529 HF90 CL RO Pre Filter 5626903 H...

Страница 19: ...19 Notes...

Страница 20: ...1 year from the date of purchase The filter cartridge or membrane is warranted to be free from defects in material and manufacture for one 1 year No warranty is given as to the service life of any fi...

Отзывы: