NOTICE

NOTICE

To reduce the risk associated with property damage due to water leakage or fl ooding:

• Read and follow Use Instructions before installation and use of this system.
• Change the disposable fi lter cartridge at the recommended interval; the disposable pre-fi lter cartridge and post-fi lter cartridge MUST be 
replaced every 24 months or sooner.  
• Change the disposable membrane fi lter cartridge at the recommended interval; the disposable RO membrane cartridge MUST be replaced 
every 24 months or sooner.  
• Failure to replace the disposable fi lter and membrane cartridges at recommended intervals may lead to reduced fi lter performance and failure 
of the fi lters, causing property damage from water leakage or fl ooding.
• Installation and use MUST comply with all state and local plumbing codes.
• Protect from freezing, remove fi lter cartridge when temperatures are expected to drop below 33° F (4.4° C).
• DO NOT install systems in areas where ambient temperatures may go above 110° F (43.3° C).
• DO NOT install on hot water supply lines.  The maximum operating water temperature of this fi lter system is 100°F (37.8°C).
• DO NOT install if water pressure exceeds 125 psi (862 kPa).  If your water pressure exceeds 80 psi (552 kPa), you must install a pressure 
limiting valve.  Contact a plumbing professional if you are uncertain how to check your water pressure.
• DO NOT install where water hammer conditions may occur.  If water hammer conditions exist you must install a water hammer arrester.  
Contact a plumbing professional if you are uncertain how to check for this condition.
• Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion MUST be 
installed.  Contact a plumbing professional if you are uncertain how to select/install/maintain a thermal expansion device.
• Where a booster pump is installed on a water system, you MUST maintain and inspect the attached pressure switch regularly in accordance 
with the booster pump manufacturer’s instructions.  Contact a plumbing professional if you are uncertain how to maintain your booster pump 
system.
• Where a booster pump is installed on a water system, you MUST install an appropriate pressure relief valve.  Pressure relief valve must be 
maintained and inspected every 6 months.  Contact a plumbing professional if you are uncertain how select/install/maintain a pressure relief 
valve.
• Where a booster pump is installed on a water system, you MUST install an appropriate pressure regulating valve and regulate water pressure 
to <80psi.  Contact a plumbing professional if you are uncertain how select/install/maintain a pressure regulating valve.
• DO NOT install in direct sunlight or outdoors.
• DO NOT install near water pipes which will be in path of a drilling tool when selecting the position to mount the bracket.
• Mount fi lter in such a position as to prevent it from being struck by other items used in the area of installation.
• Ensure that the location and fasteners will support the weight of the system when installed and full of water.
• Ensure all tubing and fi ttings are secure and free of leaks.
• DO NOT install unit if collet is missing. Contact 1-866-990-9785 if collets are missing from any fi ttings.
• Use compatible fl exible tubing with ‘push in connections’ (such as PEX tubing, PE tubing, PP tubing).
• DO NOT install with rigid piping (such as copper, aluminum, stainless steel, chrome plated, or anodized tubing).
• All hydro-pneumatic pressurized tanks MUST have an appropriate pressure relief valve installed.  Pressure relief valve must be maintained 
and inspected every 6 months.  Contact a plumbing professional if you are uncertain how to select/install/maintain a pressure relief valve.

IMPORTANT NOTES

IMPORTANT NOTES

• Failure to follow instructions will void warranty.
• Allow a minimum of 3” (6.72 cm) clear space under fi lter to facilitate cartridge change.
• Install with the inlet and outlet ports as labeled. Make sure not to reverse connections.
• Some local codes may require the use of a licensed plumber or certifi ed installer when disrupting a potable water line.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of 
experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards 
involved.
• Children shall not play with the appliance.
• Cleaning and user maintenance shall not be made by children without supervision.
• For cold water use only.

Содержание ScaleGard HP

Страница 1: ...manual with owner operator Owner Operator Please retain for operation and future instructions 3M Water Filtration Products Installation and Operation Instructions for ScaleGardTM HP Reverse Osmosis S...

Страница 2: ...aution Statements 4 Parts List 5 Feedwater Requirements 6 Other Requirements 6 Equipment Set Up and Installation 7 System Start Up 10 Routine Maintenance 15 16 Troubleshooting Guide 17 Product Replace...

Страница 3: ...is higher than 80 psi install a pressure reducing valve before installing the water filtration system An approved post filter and tank must be used with the RO system To reduce the risk associated wit...

Страница 4: ...T install an appropriate pressure relief valve Pressure relief valve must be maintained and inspected every 6 months Contact a plumbing professional if you are uncertain how select install maintain a...

Страница 5: ...ilter and RO with UK plug 6239304 220 240VAC w out Pre filter and RO with AU plug HF90 CL RO Pre Filter 1 5613529 HFRO 500 RO membrane 1 5626903 Equipment Components Sold Separately Description Quanti...

Страница 6: ...PN 50 93201 If the particle count is 1000 counts ml for particles less than 2 micron size or turbidity is greater than the recommended 5 ntu limit then it may be required to consider different prefilt...

Страница 7: ...leGard HP reverse osmosis base unit and 0 5 or larger tubing diameter is required to complete installation Figure 1 Plumbing Diagram Bypass Provided by Installer Check Valve Provided by Installer 1 2...

Страница 8: ...with property damage due to water leakage or flooding Mount ScaleGardTM HP base unit in such position as to prevent it from being struck by other items being used in the area of installation Ensure t...

Страница 9: ...Plumbing connections for the ScaleGardTM HP reverse osmosis system are now complete Install cartridge per instructions below Pre Filter and Post Filter Cartridge blue label Installation 1 Remove red s...

Страница 10: ...ee Figure 1 page 7 2 Turn ON the feedwater supply by plugging system into electrical outlet 3 Open Pre Filter flush valve to vent air from system and flush for 10 gallons approximately 5 minutes If er...

Страница 11: ...after the desired TDS value is reached Re adjust and check as needed See Figure 5 item 2 below 4 Lock the blending valve using the lock nut 5 After TDS is set drain RO tank System is now ready for use...

Страница 12: ...BLUE BROWN Step Down Transformer 3 WIRE NUT 8 LEVER NUT 14 11 6 LEVER NUT 5 LEVER NUT 7 LEVER NUT TERMINAL BLOCK Output LED Color Meaning Normal Running Condition PWR Green On when the units power co...

Страница 13: ...bar for 220 240VAC systems the unit is off on full tank 1 Unit will cycle on when tank switch senses 40 psi TOGGLE CYCLE 1 Motor Pump stop 2 2 second delay the inlet solenoid closes 3 1 second delay t...

Страница 14: ...is is normal To reduce the risk associated with property damage due to water leakage or flooding Notice Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if...

Страница 15: ...low their guidelines as you install the water filtration system Your water filtration system will withstand up to 125 pounds per square inch psi water pressure If your water supply pressure is higher...

Страница 16: ...pressure 2 Release tubing 3 Cut off at least 1 4 from end 4 Reattach tubing 5 Confirm connection is leak free Figure 9 How to Use Push in Connectors 4 Remove sanitary cap from new RO membrane cartridg...

Страница 17: ...e Check for 1 feedwater pressure 2 production flow rate 3 drain flow rate before replacing RO membrane Ensure drain line is not kinked or plugged Replace if needed RO membrane fouls high feed water ha...

Страница 18: ...ge Contact Dealer 60 125001 Permeate Solenoid Contact Dealer 85 9274 Shroud Contact Dealer 89 3220101 Pump Head Contact Dealer 89 2302 Pump Motor Contact Dealer 5613529 HF90 CL RO Pre Filter 5626903 H...

Страница 19: ...19 Notes...

Страница 20: ...1 year from the date of purchase The filter cartridge or membrane is warranted to be free from defects in material and manufacture for one 1 year No warranty is given as to the service life of any fi...

Отзывы: