background image

17

2.0 Use

2.1 

FALL PROTECTION AND RESCUE PLAN:

 The employer must have a Fall Protection and Rescue Plan in place that meets 

ANSI Z359.2 Minimum Requirements for a Comprehensive Managed Fall Protection Program

. The plan should provide 

guidelines and requirements for an employer’s managed fall protection program, including policies, duties and training; 

fall protection procedures; eliminating and controlling fall hazards; rescue procedures; incident investigations; and 

evaluating program effectiveness.

2.2 

INSPECTION FREQUENCY:

 SRDs shall be inspected by the authorized person

1

 or rescuer

2

 before each use (See Table 

3). Additionally, inspections shall be conducted by a competent person

3

 other than the user. Extreme working conditions 

(harsh environment, prolonged use, etc.) may necessitate more frequent competent person inspections. The competent 

person shall use the 

Inspection Schedule (Table 2)

 to determine appropriate inspection intervals. Inspection procedures 

are described in the 

Inspection & Maintenance Log (Table 3)

. Results of the Competent Person inspection should be recorded 

in the 

Inspection and Maintenance Log 

or recorded with the Radio Frequency Identification (RFID) system.

2.3 

NORMAL OPERATIONS:

 Normal operation will allow the lifeline to extend and retract with no hesitation or slack as 

the worker moves at normal speeds. If a fall occurs, a speed sensing brake system will activate, stopping the fall and 

absorbing much of the energy created. Sudden or quick movements should be avoided during normal work operation, as 

this may cause the SRD to lock up. For falls which occur near the end of the lifeline travel, a reserve lifeline system or 

Energy Absorber has been incorporated to reduce the fall arrest forces.

2.4 

BODY SUPPORT:

 A Full Body Harness must be used with the Self-Retracting Device. The harness connection point must 

be above the user’s center of gravity. A body belt is not authorized for use with the Self-Retracting Device. If a fall occurs 

when using a body belt it may cause unintentional release or physical trauma from improper body support.

2.5 

COMPATIBILITY OF COMPONENTS:

 Unless otherwise noted, 3M equipment is designed for use with 3M approved 

components and subsystems only. Substitutions or replacements made with non approved components or subsystems may 

jeopardize compatibility of equipment and may affect safety and reliability of the complete system.

2.6 

COMPATIBILITY OF CONNECTORS:

 Connectors are considered to be compatible with connecting elements when they 

have been designed to work together in such a way that their sizes and shapes do not cause their gate mechanisms to 

inadvertently open regardless of how they become oriented. Contact 3M if you have any questions about compatibility. 

Connectors (hooks, carabiners, and D-rings) must be capable of supporting at least 5,000 lbs. (22.2 kN). Connectors 

must be compatible with the anchorage or other system components. Do not use equipment that is not compatible. 

Non-compatible connectors may unintentionally disengage (see Figure 5). Connectors must be compatible in size, shape, 

and strength. Self-locking snap hooks and carabiners are required. If the connecting element to which a snap hook or 

carabiner attaches is undersized or irregular in shape, a situation could occur where the connecting element applies a 

force to the gate of the snap hook or carabiner (A). This force may cause the gate to open (B), allowing the snap hook or 

carabiner to disengage from the connecting point (C).

2.7 

MAKING CONNECTIONS:

 Snap hooks and carabiners used with this equipment must be self-locking. Ensure all 

connections are compatible in size, shape and strength. Do not use equipment that is not compatible. Ensure all 

connectors are fully closed and locked. 3M connectors (snap hooks and carabiners) are designed to be used only as 

specified in each product’s user’s instructions. See Figure 6 for examples of inappropriate connections. Do not connect 

snap hooks and carabiners:

A.  To a D-ring to which another connector is attached.
B.  In a manner that would result in a load on the gate. Large throat snap hooks should not be connected to standard 

size D-rings or similar objects which will result in a load on the gate if the hook or D-ring twists or rotates, unless the 

snap hook is equipped with a 3,600 lb (16 kN) gate.

C.  In a false engagement, where size or shape of the mating connectors are not compatible and, without visual 

confirmation, the connectors seem fully engaged.

D.  To each other.
E.  Directly to webbing or rope lanyard or tie-back (unless the manufacturer’s instructions for both the lanyard and 

connector specifically allows such a connection).

F.  To any object which is shaped or dimensioned such that the snap hook or carabiner will not close and lock, or that 

roll-out could occur.

G.  In a manner that does not allow the connector to align properly while under load.

Table 2  –  Inspection Schedule

Type of Use

Application Examples

Conditions of Use

Inspection Frequency

Infrequent to Light

Rescue and Confined Space, 

Factory Maintenance

Good Storage Conditions, Indoor or Infrequent 

Outdoor Use, Room Temperature, Clean Environments

Annually

Moderate to Heavy

Transportation, Residential 

Construction, Utilities, Warehouse

Fair Storage Conditions, Indoor and Extended Outdoor 

Use, All Temperatures, Clean or Dusty Environments

Semi-Annually to Annually

Severe to 

Continuous

Commercial Construction, Oil and 

Gas, Mining

Harsh Storage Conditions, Prolonged or Continuous 

Outdoor Use, All Temperatures, Dirty Environment

Quarterly to Semi-Annually

1  Authorized Person:

 A person assigned by the employer to perform duties at a location where the person will be exposed to a fall hazard.

2 Rescuer:

 Person or persons other than the rescue subject acting to perform an assisted rescue by operation of a rescue system.

3  Competent Person:

 An individual designated by the employer to be responsible for the immediate supervision, implementation, and monitoring of the employer’s 

managed fall protection program who, through training and knowledge, is capable of identifying, evaluating, and addressing existing and potential fall hazards, and 

who has the employer’s authority to take prompt corrective action with regard to such hazards.

Содержание Nano-Lok 3100468

Страница 1: ... lbs 190 kg 3101326 2 p p p 2 9 ft 2 7 m 420 lbs 190 kg 3101365 2 p 1 9 ft 2 7 m 420 lbs 190 kg 3101366 2 p 1 9 ft 2 7 m 420 lbs 190 kg 3101367 2 p 1 9 ft 2 7 m 420 lbs 190 kg 3101368 2 1 9 ft 2 7 m 420 lbs 190 kg 3101373 2 p p 2 9 ft 2 7 m 420 lbs 190 kg 3101374 2 p p 2 9 ft 2 7 m 420 lbs 190 kg 3101562 1 p p 1 11 ft 3 3 m 420 lbs 190 kg 3101563 1 p 1 11 ft 3 3 m 420 lbs 190 kg 3101565 1 p 1 11 f...

Страница 2: ......

Страница 3: ...3 2 B A D E F G C B A D E F G C B A D E F G C 3101685 3101685 ...

Страница 4: ...FC 6 1 8 7 2 1 12 ft 3 7 m ft m 1 0 3 1 0 3 2 0 6 3 0 9 4 1 2 5 1 5 2 0 6 3 0 9 4 1 2 5 1 5 6 1 8 6 1 8 8 2 4 H V FC x 1 140 kg R TM ft m 1 0 3 2 0 6 3 0 9 4 1 2 5 1 5 9 ft 2 7 m 7 ft 2 1 m 11 ft 3 6 m 5 0 ft 1 5 m FC 6 1 8 7 2 1 ft m 1 0 3 1 0 3 2 0 6 3 0 9 4 1 2 5 1 5 2 0 6 3 0 9 4 1 2 5 1 5 6 1 8 6 1 8 8 2 4 H V FC x 1 191 kg ...

Страница 5: ...5 5 6 A B C D 7 D A B C Step 1 Step 2 9 A B ...

Страница 6: ...6 10 11 12 C C 13 14 15 16 C C 17 ...

Страница 7: ...7 18 1 B A B A 2 C C D 3 E A C 4 F D D ...

Страница 8: ...8 19 1 A B B A 2 D D C E 3 G H F 4 F A 5 F E I G E 6 D D C A D D K K C J ...

Страница 9: ...9 20 1 A B 2 C D D 3 E G F 4 A E 5 E F 6 D C A ...

Страница 10: ...10 21 E D A D G F F 22 23 A B C 24 ...

Страница 11: ...11 25 26 27 28 C D B B A A E E A B C D A B ...

Страница 12: ...12 29 A B H D C I E F I J G A B Models 3101365 3101367 3101368 3101366 3101370 3101371 Models 3101365 3101366 3101367 3101368 3101373 3101374 ...

Страница 13: ...Models 3101322 3101324 3101326 Models 3101322 3101324 3101326 E F Models 3101562 3101563 3101565 Models 3101566 3101567 3101569 Models 3101562 3101563 3101565 3101566 3101567 3101569 G H Model 3100468 3101685 I J ...

Страница 14: ... the SRD Avoid sudden or quick movements during normal work operation This may cause the device to lock up Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent and ...

Страница 15: ...for use in environments where an arc flash electrical explosion could occur Table 1 Specifications Component Specifications SRL Housings Nylon Drum Nylon Internal Components Stainless Steel Aluminum Web Lifeline Standard Dynema Polyester Hot Work Kevlar Nomex Arc Flash Kevlar Nomex Energy Absorber Standard Cover Nylon Standard Web Polyester Standard Stitching Polyester or Nylon Thread Hot Work and...

Страница 16: ... path is required to assure positive locking of the SRD Free Fall Properly using an SRD in overhead applications will minimize free fall distance To prevent an increased free fall distance follow the instructions below Never clamp knot or otherwise prevent the lifeline from retracting or staying taut Avoid any slack in the lifeline of the SRD Do not work above the level of your anchorage Do not le...

Страница 17: ...tionally disengage see Figure 5 Connectors must be compatible in size shape and strength Self locking snap hooks and carabiners are required If the connecting element to which a snap hook or carabiner attaches is undersized or irregular in shape a situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner A This force may cause the gate to open B a...

Страница 18: ...ical a Single SRD Harness Interface can be used to mount the SRD on the back of a Full Body Harness just below the Dorsal D Ring see Figure 18 The worker can then connect to varied anchorage points located throughout the site with the Lanyard End of the SRD without repeatedly reinstalling the SRD To mount the SRD on a Full Body Harness with the Single SRD Harness Interface 1 Loosen the Harness Web...

Страница 19: ...nd the Web Straps until the Connector surrounds the Web Straps 5 Add the second SRD on the Harness Interface Slide the SRD s Swivel Eye F over the Nose of the Connector E and position the SRD Swivel Eye in the Nose End of the Connector 6 Close the Harness Interface Allow the Gate D to swing closed and the Locking Sleeve C to rotate back to locked position Once the Harness Interface is closed pull ...

Страница 20: ...can be used for continuous fall protection 100 tie off while ascending descending or moving laterally see Figure 22 With the Lanyard Leg of one SRD attached to an anchorage point the worker can move to a new location attach the unused Lanyard Leg of the other SRD to another anchorage point and then disconnect from the original anchorage point The sequence is repeated until the worker reaches the d...

Страница 21: ...y before allowing it to retract into the housing An excessive buildup of dirt paint etc may prevent the lifeline from fully retracting back into the housing causing a potential free fall hazard 6 2 SERVICE SRDs are not repairable If the SRD has been subjected to fall force or inspection reveals an unsafe or defective condition remove the SRD from service and discard see Disposal 6 3 STORAGE TRANSP...

Страница 22: ... properly and Locking Buttons and Locking Pins should function correctly Web Lifeline Figure 27 Inspect webbing material must be free of cuts A frays B or broken fibers Check for tears abrasions heavy soiling C mold burns D or discoloration Inspect stitching Check for pulled or cut stitches Broken stitches may be an indication that the harness has been impact loaded and must be removed from servic...

Страница 23: ...e Corrective Action Maintenance Approved By Next Inspection Due Date Corrective Action Maintenance Approved By Next Inspection Due Date Corrective Action Maintenance Approved By Next Inspection Due Date Corrective Action Maintenance Approved By Next Inspection Due Date Corrective Action Maintenance Approved By Next Inspection Due Date Corrective Action Maintenance Approved By Next Inspection Due D...

Страница 24: ... Japan 3M Japan Ltd 6 7 29 Kitashinagawa Shinagawa ku Tokyo Phone 81 570 011 321 Fax 81 3 6409 5818 psd jp mmm com WEBSITE 3M com FallProtection I S O 9 0 0 1 FM534873 EU DECLARATION OF CONFORMITY 3M com FallProtection DOC GLOBAL PRODUCT WARRANTY LIMITED REMEDY AND LIMITATION OF LIABILITY WARRANTY THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED INCLUDING THE IMPLIE...

Отзывы: