Program

Select HEAT with the HEAT/Cool MODE switch. 

To select the 

DAY

 you want to program

: Press 

PROGRAM

 to enter 

programming mode. The

PROGRAM

 icon will come on. The day icon will show 

SU

 (Sunday). Press

day

         again to advance the day selection. 

Select the TIME SLOT you want to program: 

To change the TIME SLOT

(

MORN, DAY, EVEN, NITE

) press the 

 NEXT

      button. The display will cycle 

through the time periods in sequence.  Select 

MORN.

Select the desired temperature for that TIME SLOT : 

To change the 

temperature for that TIME SLOT press the TEMP +/- buttons.

Select the time of day you want that TIME SLOT to represent:

To set the time when

MORN

 will begin , press the

<TIME

  or

TIME>

   buttons 

to move the set point forward or backward in time. 

Select the next TIME SLOT and program temp and time: 

Press

NEXT>

    the display will show 

DAY

. Repeat setting temp and time. 

Select the remaining TIME SLOT's, 

EVEN

and

NITE.

Program their temp and 

time info.  Repeat the above procedures for each day of the week. 
Push

DAY>

    button to cycle through the days.

To

COPY

 the program of the current day to another day, press COPY

program once.  COPY will display on the LCD. The day icon for the source 
day will go solid and the day icon for the destination day will flash.  Use day 
button to select the destination day.  Press COPY again to confirm the copy.
If you decide you don't want to copy, press HOME to exit.

NOTE:

60 Second Rule-During

 programming, if a button is not 

pushed within 60 seconds, the unit will go out of the set mode. 

Everything you have input in this programming will automatically be saved.

NEXT

NEXT

DAY

DAY

PG

 4

PG

 5

TIME

TIME

Содержание FIltrete 22

Страница 1: ...t pumps 2 stage heat pumps zoned hot water 2 or 3 wire zoned forced air single and 2 stage cooling and hybrid systems It can not be used with 120 volt heating systems TEMP UP button TEMP DOWN button Target Temp Time Battery Compartment Control Panel Reset button Heat Cool Mode Switch Fan Switch Front Cover Operation Guide 3M 22 ENGLISH ...

Страница 2: ...for you If it does not fit your needs you can always input a custom program To Run the energy saving program select HEAT or COOL with the mode switch The unit is now running the energy saving program To return to the energy saving program press EPA One of the TIME SLOT icons MORN DAY EVEN NITE comes on this indicates the TIME SLOT active in the energy saving program For program details refer to th...

Страница 3: ...rd or backward in time Select the next TIME SLOT and program temp and time Press NEXT the display will show DAY Repeat setting temp and time Select the remaining TIME SLOT s EVEN and NITE Program their temp and time info Repeat the above procedures for each day of the week Push DAY button to cycle through the days To COPY the program of the current day to another day press COPY program once COPY w...

Страница 4: ...h the programmed times and temps showing each program for 12 seconds Starting from Sunday MORN and ending on Saturday NITE The programmed temperature is shown on the left of the LCD the programmed time day and time slot are shown on the right and the right top of the LCD respectfully Press HOME to leave program REVIEW mode and run the program Program cont DAY SWING setting determines the temperatu...

Страница 5: ...OLD button The HOLD icon comes on Push the UP or DOWN arrow buttons to set the hold temperature HOLD is canceled if the MODE switch is moved or press HOLD again PG 9 Manual With the MODE switch in HEAT or COOL push the TEMP buttons to temporarily change the control temperature by 1 degree per step Press and hold for faster setting The OVERRIDE icon flashes to shows the displayed temperature may be...

Страница 6: ...ife of a HVAC filter varies depending on many factors furnace run time and this will vary from the filter life noted on the filter media The 3M 22 has a feature that keeps track of actual furnace run time and reminds you to periodically replace your system s air filter Press the FILTER button once to review the current filter record The FILTER and WKS icons come on with filter run hours being disp...

Страница 7: ... Press HOME to save the new setting TIME Calibration PG 13 PG 12 C or F display Celsius Fahrenheit selection The C F jumper is on the top left of the 3M 22 Separate the control unit from the wall mounted terminals When changed the thermostat must be reset to activate the change When resetting all custom settings and programming will be erased and only the energy saving program will remain 12 24 ho...

Страница 8: ...ting and cooling systems from damage This thermostat uses a new technique called sequential staging for more comfort with faster reaction to requested temperature changes when controlling 2 stage systems 3M 22 Features If you have a heat pump with auxiliary heat and the heat pump is not working properly your thermostat will still keep your room temperature within about 2F of the target temperature...

Отзывы: