5
78-8135-6695-3-C
3.0 Dielectric Main Cable Preparation (No Ground)
72” (1.8m)
SHEATH REMOVED
TYPICAL CENTRAL TUBE
CABLE PREP
6” (150mm)
TRIM SINGLE OR
DUAL CSM RODS
8” (200mm)
CENTRAL TUBE
TRIMMED
72” MAX (1.8m)
SHEATH REMOVED
TYPICAL CABLE PREP
6”(150mm)
TRIM SINGLE OR
DUAL CSM RODS
3”(75mm)
SCUFF SHEATH
ON ALL CABLES
72” MAX (1.8m)
SHEATH REMOVED
TYPICAL CABLE PREP
6”(150mm)
TRIM SINGLE OR
DUAL CSM RODS
8”(200mm)
CENTRAL TUBE
48” (1.2m)
SHEATH REMOVED
TYPICAL CABLE PREP
6” (150mm)
TRIM SINGLE OR
DUAL CSM RODS
EXPRESS LOOSE BUFFER TUBE CABLE
EXPRESS CENTRAL TUBE CABLE
BRANCH OR DROP CABLE
4.0 Armored Main Cable Preparation
6” (150mm)
TRIM CSM ROD(S)
4” (200mm)
LEAVE HALF OF CABLE SHEATH
W/METALLIC SHIELDING TO
ATTACH GROUNDING
MEASURE SHEATH OPENING
TO HERE