Page 8
Voltage Test
or
Selects T-R or R-G or T-G
Selects
AC or DC measurements
This function measures the DC or AC voltage between the
test leads. The test begins by displaying the voltage from
the Red to Black lead in the center box. This box has a
thicker border than the others indicating that this reading is
‘live’ and will change as the voltage on the leads change.
Pressing
moves the ‘live’ reading to one of the other
boxes showing the voltage from the Red to Ground lead or
Black to Ground lead. The boxes not currently ‘live’
retain their last measurement on the screen from memory.
Press the
key to select between DC and AC volts. The
icon in the lower right area of the screen will change from
DC to AC. Press
again to change back.
This symbol indicates that a high voltage has
been detected between the test leads. The
945DSP has opened an internal relay to protect
itself from damage. Use standard safety practices for
disconnecting the test leads since high voltage may be
present and press
to reset the unit. In the volts test, this
warning appears if the voltage exceeds 350V. For most
other tests the limit is 75V. Tests that involve a working
circuit have a limit of 25V when in the offhook condition.
Tip
– The
key can be used as a shortcut for the
key.
Press
to enter the voltage test and then each subsequent
press of the
key cycles to the next measurement.
Содержание Dynatel 945DSP
Страница 2: ...Dynatel 945DSP Subscriber Loop Tester Instruction Manual March 8 2004 78 8130 3440 8 Rev B ...
Страница 11: ...Page 7 Then press the desired test or control key ...
Страница 36: ...Telecom Systems Division 6801 River Place Blvd Austin Texas 78726 9000 USA http www mmm com telecom 3M 2000 ...