background image

26

Form No: 5903917   Rev: D

3M™ DBI-SALA

®

 RoofSafe Anchor and Cable System

Maintenance Check List
Section 20.0

Maintenance Check Sheet

CHECKLIST    

NOTES

ALL SYSTEMS  

  Visual inspection. Check system for signs of a fall event

  Check system ID Tag is present and legilble

  Check all components for signs of damage, rusting or severe corrosion

  Check all components are isolated from disimilar metals

 

Check 

integrity 

of 

structure 

 

 

       

  Check split pins present and in good condition 

    

 

 

 

 

  Check that Unieyes/End Anchorages are correctly orientated and in good condition 

    

 

  Check fasteners are correctly tightened. Use Torque Wrench as required 

  Proof load test concrete fixings to 6kN

 

Clean 

system 

as 

necessary 

 

 

       

  Check Attachment Devices operate correctly 

 

 

       

CABLE SYSTEMS 

  Uni 16™ Only. Check finishing kit elements are present and intact

  Check cable condition for fretting, corrosion, signs of contamination and damage

  Cable tension OK

  Check Uni 8™ Tensioners for correct thread engagement and ensure lock nuts are tight

  Check inline energy absorbing elements are intact

  Check intermediate brackets are not deployed and nylon shear pins are intact

RoofSafe™ Anchors 

  Check energy absorbing elements are not deployed

  Ensure all waterproofing elements are present and intact

  Check standing seam clamps with a torque wrench 

 

 

       

RAIL SYSTEMS 

  Check system, carriage and end stops are securely fixed

  Check system for cracks in rail

  Check rail for signs of deformation

  Roofsafe rivets hand checked for secure fixing - tug anchorage at each section

  Check all joints are securely fixed

  RoofSafe™ - Check spreader plate correctly riveted in X pattern

  RoofSafe™ - Check grub screws in corners are secure. Torque to 5Nm

Site Name:

Site Address:

  System in good condition and cleared for use 

  System not acceptable, further action required

Inspector’s 

 

Print   

Next Inspection 

Signature  

   

Name  

 

  Due Date 

NOTES AND IMPORTANT OBSERVATIONS

CUSTOMER INFORMATION

INSPECTOR INFORMATION

INSPECTION INFORMATION

3M Fall Protection ID No:

Name:

Address:

Telephone:

Inspection Date:

System Type:  

 Stand Seam RA   

 Top Fix RA   

 Single Ply RA   

 Secret Fix RA   

 Bituminous RA   

 Uni 8™ 7x7   

 Uni 16™   

 Uni 8™ Overhead   

 UniRail™   

 RoofSafe™   

 Cabloc™   

 Cabloc™ Pro   

 Other      

   

System ID/Reference No:

ALL CHECKS MUST BE CARRIED OUT IN ACCORDANCE WITH CURRENT TECHNICAL DOCUMENTATION AND INSTRUCTIONS.

Form No: 5903917   Rev: D

Содержание DBI-SALA RoofSafe Anchor

Страница 1: ...www 3M com FallProtection Form No 5903917 Rev D Always read and follow the warnings and instructions for use 3M DBI SALA RoofSafe Anchor and Cable System User Instruction Manual ...

Страница 2: ...ors Anchor 13 9 0 Maintenance Check List Anchor 14 10 0 Foreword Cable 15 11 0 The RoofSafe Cable System 16 12 0 System Design Installation And Fixings Cable 17 13 0 Precautions Requirements Exclusions Cable 18 14 0 Inspection Maintenance Servicing And Warranty Cable 19 15 0 Pre Use In Use Checks Cable 20 16 0 Using The System Cable 21 22 17 0 Following Installation Cable 23 18 0 System Layout Cab...

Страница 3: ...tent persons trained by 3M Fall Protection or 3M Fall Protection s representative and must be in accordance with 3M Fall Protection s technical instructions and all prevailing national standards The manufacturer of the 3M DBI SALA RoofSafe Anchor is 3M Fall Protection All users of the anchor as well as those who manage its use and maintenance should be familiar with the user checks limitations pre...

Страница 4: ...ve been designed to re orientate and deploy an energy absorber in the event of a fall there by reducing the load transferred to the roofing system as compared to a rigid anchor The Anchors can be used for both fall arrest and work restraint applications The Anchors can be installed on standing seam bituminous and PVC membrane composite built up and membrane and fragile roofing systems Both Anchors...

Страница 5: ...A Restraint System is designed to prevent a user accessing risk areas such as roof edges thereby preventing a fall Fall Arrest A Fall Arrest System allows access to a fall hazard and is designed to safely arrest the operative in the event of a fall 01 02 Pre deployed Deployed Report to an certified 3M Fall Protection Installer and do not use Important Note Whilst all Anchor installations must be d...

Страница 6: ... required to successfully install and test the product Included in this manual is a checklist of the minimum amount of information that should be supplied by the installer following the installation of your Anchor s 3 3 Fixings It is imperative that the supporting structure is capable of withstanding at least twice the loads that will be generated in the event of a fall A structural engineer shoul...

Страница 7: ...lers carry the appropriate test equipment for testing the Anchor and fixings The Anchor s must not be used as a lifting system Do not use the Anchor for equipment tie back Never exceed the recommended number of users on the Anchor See label on product or system tag Never attempt to repair tamper with or change the Anchor s Do not use the system if it appears to be damaged or appears to have parts ...

Страница 8: ...the Anchor s with acids bitumen cement chloride paint or aggressive cleaning fluids Stainless Steel parts are particularly susceptible to pitting corrosion from chlorine so avoid exposure in this type of environment If the system is likely to be contaminated please contact your 3M Fall Protection Certified Installer or 3M Fall Protection for advice 5 2 Servicing In accordance with manufacturers re...

Страница 9: ...t required for use be kept in dedicated cabinets which permit adequate ventilation 6 2 The Anchor Carry out a visual inspection to check that the Anchor s components have not been subjected to damage between periods of use Check for any obvious damage such as cracks heavy indentations deformation or severe corrosion Deformation and indentations may be evidence that a fall has occurred Check for ch...

Страница 10: ...are compatible in size shape and strength Do not use equipment that is not compatible Contact 3M Fall Protection if you have any questions about compatibility 3M Fall Protection connectors snap hooks and carabiners are designed to be used only as specified in each product s user s instructions See Fig 4 for inappropriate connections Snap hooks and carabiners should not be connected A To a D ring t...

Страница 11: ...rd to the rear D ring of the harness This prevents the lanyard getting in the way during use Always ensure make compatible connection only Always ensure that the locking mechanism of the carabiner is properly closed before proceeding If an additional delta link is used make sure the nut is securely fastened 01 02 03 Inspect the Anchor to ensuring that it is secure and the attachment eye is free to...

Страница 12: ...Recorded and indicated the minimum ground clearance Provided the contact details of 3M Fall Protection Provided the contact details of the Installation company The maximum number of users permitted to use the on the Anchor and where this information can be found The next service date 7 2 Training The Certified 3M Fall Protection Installer should provide the end user with training on how to use the...

Страница 13: ...rm No 5903917 Rev D 3M DBI SALA RoofSafe Anchor and Cable System Typical Anchors Section 8 0 Standing Seam Roof Anchor Bituminous Membrane Roof Composite Built Up Roof PVC Membrane Roof Form No 5903917 Rev D ...

Страница 14: ...mediate brackets are not deployed and nylon shear pins are intact RoofSafe Anchors Check energy absorbing elements are not deployed Ensure all waterproofing elements are present and intact Check standing seam clamps with a torque wrench RAIL SYSTEMS Check system carriage and end stops are securely fixed Check system for cracks in rail Check rail for signs of deformation Roofsafe rivets hand checke...

Страница 15: ...ion certified Installer or competent persons trained by 3M Fall Protection or 3M Fall Protection s representative and must be in accordance with the 3M Fall Protection s technical instructions and all prevailing national standards The manufacturer of the 3M DBI SALA RoofSafe Cable System is 3M Fall Protection All users of the System as well as those who manage its use and maintenance should be fam...

Страница 16: ...nce with current regulations The System has been tested and conforms to the requirements of EN 795 2012 TYPE C TS 16415 2013 TYPE C AS NZS 1891 2 and is OSHA Compliant SpiraTech Anchor Single Point Tip Over Anchor Used as a an End corner Anchor with the system Used as a an Intermediate Anchor only Must not be used as an end corner anchor 11 2 Positioning the 3M DBI SALA RoofSafe Cable System When ...

Страница 17: ...in this manual is a checklist of the minimum amount of information that should be supplied by the installer following the installation of your Anchor s 12 3 Fixings It is imperative that the supporting structure is capable of withstanding at least twice the loads that will be generated in the event of a fall A structural engineer should verify this is the case before a system is installed Furtherm...

Страница 18: ...or testing the Anchor and fixings The System must not be used for lifting Do not use the system for equipment tie back Never exceed the recommended number of users on the system See label on product or system tag Never attempt to repair tamper with or change the System Do not use the system if it appears to be damaged or appears to have parts missing The equipment should not be used outside of its...

Страница 19: ...ggressive cleaning fluids Stainless Steel parts are particularly susceptible to pitting corrosion from chlorine so avoid exposure in this type of environment If the system is likely to be contaminated please contact your 3M Fall Protection Certified Installer or 3M Fall Protection for advice 14 2 Servicing In accordance with current national standards and 3M Fall Protection s recommendations an An...

Страница 20: ... 3M Fall Protection carabiner be used with the UniGrab Before attaching to the 3M DBI SALA RoofSafe Cable system 1 Check that the slot does not exceed 6 1 mm 2 Check that the UniGrab cannot be opened when the carabiner is attached to the UniGrab 4 5 mm to 6 1 mm If in doubt Ask UniGrab 15 3 Compatibility of Components Prior to accessing the system the user should always inspect the system label an...

Страница 21: ...uld use other safety equipment such as a twin tailed lanyard to facilitate safe access to the attachment area 16 3 Attaching to the System The UniGrab is designed in such a way that it is possible to enter the system at any point They re carried out as follows 01 04 02 05 03 To open 8 mm UniGrab slide top tab to the left and lift upwards Attach the 2001000 carabiner and lanyard Ensure that carabin...

Страница 22: ... is attached and the attachment point of the UniGrab should be facing towards the side you want to walk on 16 4 Working on both sides of the 3M Fall Protection System To remove the UniGrab reverse the procedure on page 9 If you wish to walk on the opposite side of the system you may turn the UniGrab around Firstly attach a secondary lanyard or twin tailed lanyard to the system Then detach the UniG...

Страница 23: ...lation A unique identification number The number and length of systems The maximum number of users per span and per system The length and type of lanyards The installation date The date of the next necessary service The name and contact details of the installation company The name of the installation engineer and or supervisor A representative of the installation company should sign the certificat...

Страница 24: ...ORD DATE SYM ECO DESCRIPTION DR APP NJ 48894 C 06 07 16 1 CONVERT TO ILLUSTRATOR AKT TOLERANCES ON 2 PL DECIMALS 3 PL DECIMALS ANGLES FRACTIONS UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES SIGNATURES DATE SCALE TITLE This document is the copyrighted property of the 3M Company and may not be reproduced without 3M written permission or used for other than 3M authorized purposes 3M COPYRIGHT R...

Страница 25: ...stem Components Section 19 0 7241161 RoofSafe System Eye Pin 7241408 8 mm 90 Corner 7234011 8 mm Hex Swage Toggle 7240166 8 mm 0 8 kN Hex Swage Tensioner 7241411 8 mm 45 Corner 7234020 8 mm UniGrab Carabiner 7241412 8 mm Intermediate Guide 7241413 8 mm Variable Guide Form No 5903917 Rev D ...

Страница 26: ...mediate brackets are not deployed and nylon shear pins are intact RoofSafe Anchors Check energy absorbing elements are not deployed Ensure all waterproofing elements are present and intact Check standing seam clamps with a torque wrench RAIL SYSTEMS Check system carriage and end stops are securely fixed Check system for cracks in rail Check rail for signs of deformation Roofsafe rivets hand checke...

Страница 27: ...ith such emergencies cannot be overemphasized Such a plan includes consideration of rescue equipment personnel and training as necessary It is not acceptable just to rely on the emergency services Emergency procedures need to be considered for reasonably foreseeable circumstances The measures need to be covered in the risk assessment and planned prior to the work activity being carried out A sensi...

Страница 28: ... 06511 Carros Le Broc Cedex France Phone 33 04 97 10 00 10 Fax 33 04 93 08 79 70 informationfallprotection mmm com Australia New Zealand 95 Derby Street Silverwater Sydney NSW 2128 Australia Phone 61 2 8753 7600 Toll Free 1800 245 002 AUS Toll Free 0800 212 505 NZ Fax 61 2 8753 7603 anzfallprotectionsales mmm com Asia Singapore 1 Yishun Avenue 7 Singapore 408731 Phone 65 65587758 Fax 65 65587058 t...

Отзывы: