24
Form No: 5903917 Rev: D
3M™ DBI-SALA
®
RoofSafe Anchor and Cable System
System Layout
Section 18.0
Detailed below are examples of typical components used in a 3M™ DBI-SALA
®
RoofSafe Anchor system along with the tools
required for installation.
It is advisable to read through these instructions before beginning the installation.
A RoofSafe Anchor System Eye & Pin Unieye
B 8 mm Hex Swage Tensioner
C 8 mm 7 x 7 SS Cable Per M
D 8 mm UniGrab & Carabiner
E RoofSafe Anchor Intermediate Guide
F 90 Degree Corner
45 Degree Corner**
8 mm Variable Bracket**
G 8 mm Hex Swage Toggle
H RoofSafe Anchor Baseplate 405 x 405 H
I RoofSafe Anchor Module End /
Corner Bitumen
J RoofSafe Anchor Module
Intermediate Bitumen
K RoofSafe Anchor Tag EMEA L A
7234011
7241136
7241143
7241151*
7241144
7241152*
7241232
7241161
7240166
7240211
7234020
7241412
7241408
7 241411
7241413
Typical Layout for a Bitumen Roof System
SpiraTech Anchor
Tip Over Anchor
SpiraTech Anchor
SpiraTech Anchor
K
H
G
J
E
B
A
F
I
D
D
Note: Fasteners for fixing to the structure are not supplied.
*This component is different from the one illustrated
*
North American region only
** this component is different from the one illustrated
REVISION RECORD
DATE
SYM ECO
DESCRIPTION
DR APP
NJ
48894
C
06/07/16
1) CONVERT TO ILLUSTRATOR;
AKT
DO NOT SCALE
DRAWING
SHEET
1
OF
1
TOLERANCES ON:
2 PL DECIMALS ±
3 PL DECIMALS ±
ANGLES ±
°
FRACTIONS ±
UNLESS OTHERWISE SPECIFIED
DIMENSIONS ARE IN INCHES
SIGNATURES
DATE
DRAWN
CHECKED
APPROVED
DRAWING NUMBER
REVISION
SCALE
TITLE
This document is the copyrighted property of the 3M
Company and may not be reproduced without 3M written
permission or used for other than 3M authorized purposes.
© 3M COPYRIGHT
RED WING, MN, USA
1:1
NJ
ILLUSTRATOR
7241184
LABEL, RA SYS TAG EMEA-A
06/07/16
AKT
06/07/16
06/07/16
AKT
E
7241184 Rev. E
NOTES:
1. MATERIAL: .031 ±.004 [0.8mm ± 0.1mm] ALUMINUM 5005
2. FINISH: ANODIZED, SCREEN PRINTED BLACK, BLUE Pantone 2748, LOW TEMPERATURE BAKED.
3.
USE THE CURRENT REVISION OF FILE 7241184.ai FOR LABEL GEOMETRY AND ARTWORK.
ALL LABEL GEOMETRY TOLERANCE SHALL BE ±.010.
Ø.157 [4mm]
2 PLACES
LABEL DIMENSIONS
LABEL GRAPHICS
3.543
[90mm]
8.465
[215mm]
8.858
[225mm]
.217 [5.5mm]
.197 [5mm]
3.937
[100mm]
Ø.197 [5mm] TYP.
.874 [22.2mm]
.276 [7mm]
2.008 [51mm]
NJ
2) ADD “CE 1019” TEXT TO LABEL;
AKT
NJ
3) REMOVE CAPITAL SAFETY LOGO
AKT
3M.com/FallProtection
EN795: 2012 Type C
CEN TS 16415:2013 Type C
OSHA 1926.502
AS/NZS 1891.2
NJ
52426
D
06/27/17
1) CHANGE EN795 MARK TO 2012; 2) ADD
AKT
NJ
TEXT: CEN TS 16415: 2013; 3) REMOVE
AKT
NJ
CE 1019; 4) UPDATE TO 3M LOGO AND
AKT
NJ
WEBSITE; 5) REMOVE ® AND ™ MARKS
AKT
NJ
FROM ROOFSAFE & SPIRATECH TEXT;
AKT
NJ
6) ADD 1926.502 TO OSHA; 7) REVISE NOTE 2
AKT
NJ
52426
E
07/25/17
1) “TYPE C” WAS “CLASS C”; 2) ADD “TYPE C”
AKT
NJ
TO “CEN TS” STD
AKT