13
6.2 SERVICE:
Only 3M or parties authorized in writing by 3M may make repairs to this equipment. If the Rescue-Positioning
Device has been subject to fall force or inspection reveals an unsafe or defective conditions, remove the system from
service and destroy. Rope replacement, as well as additional maintenance and servicing procedures, must be completed
by a factory authorized service center.
6.4 EMERGENCY RELEASE OF JAMMED ROPE:
If the load has been raised very close to the Rescue-Positioning Device unit,
it may not appear possible to reach the lowering mode (orange indicator). However, an override system consisting of an
override ferrule and lever (see steps 1 & 3) is provided to release the brake. To override the brake, continue raising the
load and then lower it. Repeat as required until lowering mode is reached. If this does not work, remove the load and use
the procedure below:
Step 1:
Remove the load and the screw or plug (A). See Figure 11.
Step 2:
Insert a nail or similar object at an angle into the screw hole. The nail should be 2 in. (2.54 cm) long with 1/8
in. (.32 cm) diameter.
See Figure 12.
Step 3:
Tip the nail (A) as shown to activate the brake over-ride lever. The brake override lever (B) is located internally
on the side opposite the nail. The override lever may be partially visible through the screw hole. Some force
may be required to move the override lever. See Figure 13.
Step 4:
While maintaining pressure on the nail, pull down on the line as shown. Pull out enough line to easily allow the
lowering mode to be reached.
Replace the screw or plug. See Figure 14.
6.3 STORAGE AND TRANSPORT:
Store and transport the Rescue Positioning Device in a cool, dry, clean environment out of
direct sunlight. Avoid areas where chemical vapors may exist. Thoroughly inspect the device after extended storage.
6.4 CHEMICAL HAZARDS:
Solutions containing acids, alkali or other caustic chemicals, particularly at elevated
temperatures, may damage the Rescue-Positioning Device. When working with such chemicals, frequent inspection of
the Rescue-Positioning Device must be completed. Contact 3M if doubt exists concerning use of this equipment around
chemical hazards.
6.5 HEAT:
The Rescue-Positioning Device is not intended for use in environments where incendiary sparking could cause an
explosion or fire. Use of this equipment is prohibited where there the rope could come in contact with power lines, live
cables, etc. See Table 1 for maximum service temperature.
7.0 LABELS
Figure 15 illustrates labels present on the
Device
. Figure 2 (B) shows where the labels are located. Labels must be replaced if
they are not present and fully legible.
Содержание DBI Sala Rollgliss
Страница 1: ... 3M 2020 USER INSTRUCTIONS 5902114 Rev E RollglissTM Rescue Positioning Device ANSI Z359 4 2013 ...
Страница 2: ...2 2 A B C D F E H G K J M H 3 4 A B C D E F G A B C ...
Страница 3: ...3 5 6 W FC 2 B A C 1 7 8 A B A B ...
Страница 4: ...4 9 10 11 12 A ...
Страница 5: ...5 13 14 A B 15 ...