Prior to installation and use of this equipment, record the product identification information from the ID label in the 

Inspection and Maintenance Log (Table 2) at the back of this manual.

PRODUCT DESCRIPTION:

Figure 1 Illustrates the 3M™ DBI-SALA™ Fixed Beam Anchor. The Fixed Beam Anchor is a single point anchorage connector for a 

personal fall arrest system or personal fall restraint system designed to be attached to a beam. The Fixed Beam Anchor may be 

used as an end termination for 3M Fall Protection approved horizontal lifeline systems.

Figure 2 Illustrates components of the Fixed Beam Anchor. See Table 1 for Component Specifications. The Fixed Beam Anchor is 

comprised of a notched Support Tube (A) with a Fixed Hook End (D) and an Adjustable Hook End (E) that hook over the opposite 

eges of a beam flange. The Swiveling Connector Ring (B) serves as the tie-off point for a Lanyard or Self-Retracting Device 

(SRD), with a Pin (C) holding the Connector Ring in place. The Detent Pin (F) is used to lock the Adjustable Hook End. The 

Adjustment Handle (G) is used to tighten or loosen the Adjustable Hook End on the beam flange. A Bolt (H) and Nut (I) hold the 

Fixed Hook End together. The Key Ring (J) keeps the RFID Tag (K) and Labels (L) of the Fixed Beam Anchor.

Table 1  – 

Specifications

System Specifications:

Capacity

:

One person with a combined weight (clothing, tools, etc.) of no more than 310 lbs (140 kg) for ANSI,    

420 lbs (191 kg) for OSHA.

Standards:

See Figure 1 for the applicable standards of each Fixed Beam Anchor model.

Anchorage/

Structure:

Structure must meet dimensional requirements from Figure 1. Anchorage strength must comply with 

Section 2.1 requirements.

Service 

Temperature

-40°F (-40°C)

Minimum Service Temperature

Breaking 

Strength:

 5,000 lbs (22.2 kN)

Minimum Breaking Strength

Dimensions:

See Figure 1 for the dimensions of each Fixed Beam Anchor model.

Weight:

See Figure 1 for the weight of each Fixed Beam Anchor model.

Component Specifications:

 Figure 2 

Reference

Component

Materials

A

Support Tube

Alloy steel

B

Swiveling Connector Ring

Alloy steel

C

Pin

Alloy steel

D

Fixed Hook End

Aluminum

E

Adjustable Hook End

Aluminum

F

Detent Pin

Stainless steel

G

Adjustment Handle

Aluminum

H

Bolt

Zinc plated steel

I

Nut

Zinc plated steel

J

Key Ring

Zinc plated steel

K

RFID Tag

Nylon

L

Labels

Vinyl

Содержание DBI SALA 2108406

Страница 1: ...ED BEAM ANCHOR Anchorage Connector 1 A B OSHA 1926 502 1910 140 ANSI Z359 18 Type A 2108406 2 5 in x 4 in x 20 in 5 2 lbs 2 5 in 12 in 1 5 in 2108407 2 5 in x 4 in x 26 in 5 9 lbs 2 5 in 18 in 1 5 in 2108408 2 5 in x 4 in x 32 in 6 7 lbs 2 5 in 24 in 1 5 in 2108410 2 5 in x 5 in x 45 in 9 1 lbs 12 in 36 in 1 5 2 5 in A B ...

Страница 2: ...2 2 2108406 2108408 2108410 3 4 C B A FC B C FC 5 6 A B C D E F G A B C B D A F E G J K L I H C ...

Страница 3: ...3 7 A B C D 8 9 1 2 3 4 ...

Страница 4: ...4 10 A B 11 A C B D A B C D ...

Страница 5: ...by the drill or the device Ensure that fall protection systems subsystems assembled from components made by different manufacturers are compatible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems To reduce the risks associated with w...

Страница 6: ...dle G is used to tighten or loosen the Adjustable Hook End on the beam flange A Bolt H and Nut I hold the Fixed Hook End together The Key Ring J keeps the RFID Tag K and Labels L of the Fixed Beam Anchor Table 1 Specifications System Specifications Capacity One person with a combined weight clothing tools etc of no more than 310 lbs 140 kg for ANSI 420 lbs 191 kg for OSHA Standards See Figure 1 fo...

Страница 7: ...ments along with system applications are specified below unless noted or defined otherwise in Table 1 Fall Protection System Certified Anchorage9 Non Certified Anchorage10 Defined by Fall Arrest 2 times maximum arresting force 5 000 lbs 22 2 kN OSHA ANSI Restraint Travel Restraint 2 times foreseeable force 1 000 lbs 4 4 kN per ANSI 5 000 lbs 22 2 kN per OSHA OSHA ANSI Work Positioning 2 times fore...

Страница 8: ...which a snap hook or carabiner attaches is undersized or irregular in shape a situation could occur where the connecting element applies a force to the gate of the snap hook or carabiner A This force may cause the gate to open B allowing the snap hook or carabiner to disengage from the connecting point C Self locking snap hooks and carabiners are required by ANSI Z359 and OSHA 2 9 MAKING CONNECTIO...

Страница 9: ... adjustment pin Following installation the Fixed Beam Anchor must be solid and securely attached to the structure without any looseness 4 0 USE 4 1 BEFORE EACH USE Verify that your work area and Personal Fall Arrest System PFAS meet all criteria defined in Section 2 and a formal Rescue Plan is in place Inspect the Fixed Beam Anchor per the User inspection points defined on the Inspection and Maint...

Страница 10: ...G STORAGE 6 1 CLEANING Periodically clean the Fixed Beam Anchor s metal components with a soft brush warm water and a mild soap solution Ensure parts are thoroughly rinsed with clean water 6 2 SERVICE Only 3M or parties authorized in writing by 3M may make repairs to this equipment If the Fixed Beam Anchor has been subject to fall force it must be removed from service immediately clearly marked DO...

Страница 11: ...l Personal Fall Arrest System PFAS equipment harness SRL etc that are used with the Anchorage System should be installed and inspected per the manufacturer s instructions Structure Verify the structure to which the anchor is attached meets the strength requirements from Table 1 in all possible directions of loading The structure must be free of any damage Serial Number s Date Purchased Model Numbe...

Страница 12: ...systèmes intégrés critiques Assurez vous que les systèmes sous systèmes de protection antichute assemblés à partir de composants fabriqués par différents fabricants sont compatibles et répondent aux exigences des normes applicables y compris la norme ANSI Z359 ou d autres codes normes ou exigences de protection antichute applicables Consultez toujours une personne qualifiée ou compétente avant d u...

Страница 13: ...églage G est utilisée pour serrer ou desserrer l extrémité du crochet réglable de la bride de poutre Un boulon H et un écrou I maintiennent l extrémité du crochet fixe L anneau brisé J conserve l étiquette RFID K et les étiquettes L de l ancrage de poutre fixe Tableau 1 Spécifications Spécifications du système Capacité Le poids combiné d une personne avec vêtements outils etc ne doit pas dépasser ...

Страница 14: ...hniques afin de pouvoir accomplir un sauvetage réussi La formation doit être répétée régulièrement afin d assurer l efficacité des sauveteurs 1 6 FRÉQUENCE D INSPECTION Le connecteur d ancrage doit être inspecté par l utilisateur avant chaque utilisation et en outre par une personne qualifiée autre que l utilisateur à des intervalles n excédant pas une fois par an 8 Les procédures d inspection son...

Страница 15: ...S L équipement 3M est destiné à être utilisé uniquement avec des composants et des sous systèmes approuvés par 3M Les substitutions ou les remplacements effectués avec des composants ou des sous systèmes non approuvés peuvent affecter la compatibilité de l équipement ainsi que la sécurité et la fiabilité du système dans son ensemble 2 8 COMPATIBILITÉ DES CONNECTEURS Les connecteurs sont considérés...

Страница 16: ...glage dispose encore de suffisamment de jeu une fois l ancrage pour poutre fixe bien serré Consultez la Figure 9 Si la goupille de réglage est tombée au fond réinstallez l ancrage pour poutre fixe en utilisant le prochain orifice le plus proche de la bride de poutre pour permettre le mouvement de la goupille de réglage Après l installation l ancrage pour poutre fixe doit être solide et solidement ...

Страница 17: ...st déterminée par les conditions de travail et l entretien Tant que le système satisfait aux critères d inspection il peut être utilisé 6 0 ENTRETIEN SERVICE ET ENTREPOSAGE 6 1 NETTOYAGE Nettoyez régulièrement les composants métalliques de l ancrage pour poutre coulissante avec une brosse douce de l eau chaude et une solution savonneuse douce Assurez vous de rincer les pièces minutieusement à l ea...

Страница 18: ... Étiquettes Figure 11 Vérifiez que toutes les étiquettes sont présentes fermement apposées et lisibles voir Étiquettes Équipement de protection individuelle EPI antichute et autres équipements Tout dispositif antichute personnel PFAS harnais ligne de vie autorétractable etc utilisé avec le système d ancrage doit être installé et inspecté conformément aux instructions du fabricant Structure Vérifie...

Страница 19: ......

Страница 20: ... or materials 3M reserves the right to require product be returned to its facility for evaluation of warranty claims This warranty does not cover product damage due to wear abuse misuse damage in transit failure to maintain the product or other damage beyond 3M s control 3M will be the sole judge of product condition and warranty options This warranty applies only to the original purchaser and is ...

Отзывы: