3M DBI-SALA 2100041 Скачать руководство пользователя страница 6

6

 

;

Prior to installation and use of this equipment, record the product identification information from the ID label in the 

Inspection and Maintenance Log (Table 2) at the back of this manual.

 

;

Always ensure you are using the latest revision of your 3M instruction manual. Visit the 3M website or contact 3M 

Technical Services for updated instruction manuals.

PRODUCT DESCRIPTION:

Figure 1 illustrates the 3M™ DBI-SALA™ Concrete Bolt Anchor. The Concrete Bolt Anchor is a single point anchorage connector 

for a personal fall arrest system designed to be attached to a supporting structure. The Concrete Bolt Anchor may also be used 

as an end termination for 3M-approved ANSI Z359.18 Type A Horizontal Lifeline Systems.

Figure 2 illustrates components of the Concrete Bolt Anchor. See Table 1 for Component Specifications. The Concrete Bolt Anchor 

is comprised of a Bolt (A) with a Flat Washer (B), D-ring (C) and D-ring Bracket (D), Flanged Spacer (E), Plastic Spacer (F), and 

Expansion Sleeve (G), as well as a Cone Nut (H) positioned on the Bolt.

Table 1  – 

Specifications

System Specifications:

Capacity

:

One person with a combined weight (clothing, tools, etc.) of no more than 310 lb. (140 kg) for 

ANSI, or 420 lb. (191 kg) for OSHA.

Standards:

See Figure 1 for the applicable standards for each product model. Models certified to ANSI Z359.18-

2017 have also been tested in compliance with the requirements of ANSI Z359.7.

 

;

ANSI compliance and testing covers only the product and does not extend to the anchorage 

structure or substrate to which the product is attached.

Anchorage 

Strength:

Structure must meet dimensional requirements from Figure 9. Anchorage strength must comply 

with Section 2.1 requirements. 

 

;

If the user is unable to determine whether the anchorage meets these requirements, then the 

user should either seek a Qualified Person or professional engineer who is able to do so or contact 

3M Technical Services.

Service 

Temperature:

-40°C (-40°F)

Minimum Service Temperature

Minimum Breaking 

Strength:

5,000 lbf (22.2 kN)

Minimum Breaking Strength

Dimensions:

See Figure 1 for the dimensions of each product model.

Weight:

Models 2104560 and 2104568: 1.2 lb. (0.55 kg)

Component Specifications:

 Figure 2 

Reference Component

Materials

A

Bolt

Steel

B

Flat Washer

Steel

C

D-Ring

Steel

D

D-Ring Bracket

Stainless Steel

E

Flanged Spacer

Steel

F

Plastic Spacer

Plastic

G

Expansion Sleeve

Steel

H

Cone Nut

Steel

Concrete Hole Requirements - (See Figure 9)

Concrete 

Minimum 

Thickness:

(h)

Minimum 

Distance from 

Edge/Corner:

(c)

Hole Spacing:

(s)

Drilled Hole 

Diameter:

(d)

Minimum Hole 

Depth:

(y)

Concrete 

Minimum 

Compressive 

Strength:

≥6.25 in

(15.9 cm)

≥15.0 in

(38.1 cm)

≥10.0 in

(25.4 cm)

18 mm, 

11/16 in, 

or 3/4 in

≥4.13 in

(10.5 cm)

≥3000 psi 

(20.7 MPa) fully 

cured

 

;

Drill bits for drilling mounting holes must conform to ANSI requirements.

Содержание DBI-SALA 2100041

Страница 1: ...OSHA A B C D 2104560 x1 x1 4 44 in 11 28 cm 1 09 in 2 77 cm 3 02 in 7 67 cm 5 83 in 14 81 cm 2104568 x1 x1 4 44 in 11 28 cm 1 09 in 2 77 cm 3 02 in 7 67 cm 5 83 in 14 81 cm 2100041 x0 x1 4 44 in 11 28 cm 2100066 x0 x10 4 44 in 11 28 cm C D ANSI Z359 18 Type A OSHA 1926 502 OSHA 1910 140 ...

Страница 2: ...2 2 A C B D E F G H 3 4 C B A FC B C FC ...

Страница 3: ...A B C D E F G A B C 7 8 1 s s c c d 2 4 1 8 in 10 5 cm 18 mm 11 16 in 3 4 in 3 4 9 c 15 0 in 38 1 cm h 6 25 in 15 9 cm s 10 0 in 25 4 cm y 4 13 in 10 5 cm d 18mm 11 16 in 3 4 in 3000 psi 20 7 MPa h c s c y d ...

Страница 4: ... concrete Tighten bolt until red cap shears off No further adjustment is necessary after red cap shears off INSTALLATION Step 1 Step 2 Step 3 Step 4 Step 5 Concrete minimum compressive strength 3000 psi Not for use in lightweight concrete hollow block brick grout or stone 9501359 REV D Hole Depth 4 1 8 in INSPECTION Inspect anchor before each use Green seal on bolt head indicates proper installati...

Страница 5: ...ible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems CONCRETE ANCHORS Do not use device in wet or uncured concrete hollow block stone wood or other substrates or materials CONCRETE ANCHORS Prior to installation of device in an exist...

Страница 6: ...tified to ANSI Z359 18 2017 have also been tested in compliance with the requirements of ANSI Z359 7 ANSI compliance and testing covers only the product and does not extend to the anchorage structure or substrate to which the product is attached Anchorage Strength Structure must meet dimensional requirements from Figure 9 Anchorage strength must comply with Section 2 1 requirements If the user is ...

Страница 7: ...tached to an anchorage the strengths stated above must be multiplied by the number of systems attached to the anchorage See ANSI Z359 2 for more information 2 2 PERSONAL FALL ARREST SYSTEM Figure 1 illustrates the application of this Anchorage Connector Personal Fall Arrest Systems PFAS used with the system must meet applicable Fall Protection standards codes and requirements The PFAS must incorpo...

Страница 8: ...ty Connectors hooks carabiners and D rings must be capable of supporting at least 5 000 lbf 22 2 kN Connectors must be compatible with the anchorage or other system components Do not use equipment that is not compatible Non compatible connectors may unintentionally disengage see Figure 5 Connectors must be compatible in size shape and strength If the connecting element to which a snap hook or cara...

Страница 9: ...eveals an unsafe or defective condition or if there is any doubt about its condition for safe use remove the Concrete Bolt Anchor from service immediately Clearly tag the system DO NOT USE See Section 5 for more information 4 2 FALL ARREST CONNECTIONS The Concrete Bolt Anchor is designed for use in several applications The connector is in compliance with ANSI Z359 18 Type A The product application...

Страница 10: ...nce or scheduled for maintenance should be tagged DO NOT USE These equipment tags should not be removed until maintenance is performed 6 1 CLEANING Periodically clean the Concrete Bolt Anchor s metal components with a soft brush warm water and a mild soap solution Ensure parts are thoroughly rinsed with clean water 6 2 SERVICE Only 3M or parties authorized in writing by 3M may make repairs to this...

Страница 11: ...the requirements of Table 1 Verify that the concrete is free of any cracks or damage Fall Protection Equipment Additional Fall Protection equipment that is used with the system should be installed and inspected per the manufacturer instructions Serial Number s Date Purchased Model Number Date of First Use Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintena...

Страница 12: ...quire product be returned to its facility for evaluation of warranty claims This warranty does not cover product damage due to wear abuse misuse damage in transit failure to maintain the product or other damage beyond 3M s control 3M will be the sole judge of product condition and warranty options This warranty applies only to the original purchaser and is the only warranty applicable to 3M s fall...

Отзывы: