3M DBI-SALA 2100041 Скачать руководство пользователя страница 5

FORM NO: 5908299  REV: A

5

SAFETY INFORMATION

Please read, understand, and follow all safety information contained in these instructions prior to the use of this Anchorage Connector. 

FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH.

These instructions must be provided to the user of this equipment. Retain these instructions for future reference.

Intended Use:

This Anchorage Connector is intended for use as part of a complete personal fall protection system.

Use in any other application including, but not limited to, material handling, recreational or sports related activities, or other activities not described in 

the User Instructions, is not approved by 3M and could result in serious injury or death.

This device is only to be used by trained users in workplace applications.

 

!

WARNING

This Anchorage Connector is part of a personal fall protection system. It is expected that all users be fully trained in the safe installation and operation 

of their personal fall protection system. 

Misuse of this device could result in serious injury or death.

 For proper selection, operation, installation, 

maintenance, and service, refer to these User Instructions and all manufacturer recommendations, see your supervisor, or contact 3M Technical Service.

• 

To reduce the risks associated with working with an Anchorage Connector which, if not avoided, could result in serious injury or 

death:

 

-

Inspect the device before each use, at least annually, and after any fall event. Inspect in accordance with the User Instructions.

 

-

If inspection reveals an unsafe or defective condition, remove the device from service and repair or replace according to the User Instructions.

 

-

Any device that has been subject to fall arrest or impact force must be immediately removed from service and destroyed.

 

-

The device must only be installed in the specified substrates or on structures detailed in the User Instructions. Installations and use outside the 

scope of this instruction must be approved by 3M Fall Protection.

 

-

The substrate or structure to which the anchorage connector is attached must be able to sustain the static loads specified for the anchor in the 

orientations permitted in the User Instructions.

 

-

Only connect other fall protection subsystems to the designated anchorage connection point on the device.

 

-

Prior to drilling or fastening, ensure no electric lines, gas lines, or other critical embedded systems will be contacted by the drill or the device.

 

-

Ensure that fall protection systems/subsystems assembled from components made by different manufacturers are compatible and meet the 

requirements of applicable standards, including the ANSI Z359 or other applicable fall protection codes, standards, or requirements. Always 

consult a Competent or Qualified Person before using these systems.

 

-

(CONCRETE ANCHORS) Do not use device in wet or uncured concrete, hollow block, stone, wood, or other substrates or materials.

 

-

(CONCRETE ANCHORS) Prior to installation of device in an existing hole, inspect the hole for deformation, correct substrate thickness, and 

correct hole diameter and depth.

• 

To reduce the risks associated with working at height which, if not avoided, could result in serious injury or death:

 

-

Ensure your health and physical condition allow you to safely withstand all of the forces associated with working at height. Consult with your 

doctor if you have any questions regarding your ability to use this equipment.

 

-

Never exceed allowable capacity of your fall protection equipment.

 

-

Never exceed maximum free fall distance of your fall protection equipment.

 

-

Do not use any fall protection equipment that fails pre-use or other scheduled inspections, or if you have concerns about the use or suitability 

of the equipment for your application. Contact 3M Technical Services with any questions.

 

-

Some subsystem and component combinations may interfere with the operation of this equipment. Only use compatible connections. Consult 

3M prior to using this equipment in combination with components or subsystems other than those described in the User Instructions.

 

-

Use extra precautions when working around moving machinery (e.g. top drive of oil rigs) electrical hazards, extreme temperatures, chemical 

hazards, explosive or toxic gases, sharp edges, or below overhead materials that could fall onto you or your fall protection equipment.

 

-

Use Arc Flash or Hot Works devices when working in high heat environments.

 

-

Avoid surfaces and objects that can damage the user or equipment.

 

-

Ensure there is adequate fall clearance when working at height.

 

-

Never modify or alter your fall protection equipment. Only 3M or parties authorized in writing by 3M may make repairs to the equipment.

 

-

Prior to use of fall protection equipment, ensure a rescue plan is in place which allows for prompt rescue if a fall incident occurs.

 

-

If a fall incident occurs, immediately seek medical attention for the worker who has fallen.

 

-

Do not use a body belt for fall arrest applications. Use only a Full Body Harness. 

 

-

Minimize swing falls by working as directly below the anchorage point as possible.

 

-

If training with this device, a secondary fall protection system must be utilized in a manner that does not expose the trainee to an unintended 

fall hazard.

 

-

Always wear appropriate personal protective equipment when installing, using, or inspecting the device/system.

EN

Содержание DBI-SALA 2100041

Страница 1: ...OSHA A B C D 2104560 x1 x1 4 44 in 11 28 cm 1 09 in 2 77 cm 3 02 in 7 67 cm 5 83 in 14 81 cm 2104568 x1 x1 4 44 in 11 28 cm 1 09 in 2 77 cm 3 02 in 7 67 cm 5 83 in 14 81 cm 2100041 x0 x1 4 44 in 11 28 cm 2100066 x0 x10 4 44 in 11 28 cm C D ANSI Z359 18 Type A OSHA 1926 502 OSHA 1910 140 ...

Страница 2: ...2 2 A C B D E F G H 3 4 C B A FC B C FC ...

Страница 3: ...A B C D E F G A B C 7 8 1 s s c c d 2 4 1 8 in 10 5 cm 18 mm 11 16 in 3 4 in 3 4 9 c 15 0 in 38 1 cm h 6 25 in 15 9 cm s 10 0 in 25 4 cm y 4 13 in 10 5 cm d 18mm 11 16 in 3 4 in 3000 psi 20 7 MPa h c s c y d ...

Страница 4: ... concrete Tighten bolt until red cap shears off No further adjustment is necessary after red cap shears off INSTALLATION Step 1 Step 2 Step 3 Step 4 Step 5 Concrete minimum compressive strength 3000 psi Not for use in lightweight concrete hollow block brick grout or stone 9501359 REV D Hole Depth 4 1 8 in INSPECTION Inspect anchor before each use Green seal on bolt head indicates proper installati...

Страница 5: ...ible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems CONCRETE ANCHORS Do not use device in wet or uncured concrete hollow block stone wood or other substrates or materials CONCRETE ANCHORS Prior to installation of device in an exist...

Страница 6: ...tified to ANSI Z359 18 2017 have also been tested in compliance with the requirements of ANSI Z359 7 ANSI compliance and testing covers only the product and does not extend to the anchorage structure or substrate to which the product is attached Anchorage Strength Structure must meet dimensional requirements from Figure 9 Anchorage strength must comply with Section 2 1 requirements If the user is ...

Страница 7: ...tached to an anchorage the strengths stated above must be multiplied by the number of systems attached to the anchorage See ANSI Z359 2 for more information 2 2 PERSONAL FALL ARREST SYSTEM Figure 1 illustrates the application of this Anchorage Connector Personal Fall Arrest Systems PFAS used with the system must meet applicable Fall Protection standards codes and requirements The PFAS must incorpo...

Страница 8: ...ty Connectors hooks carabiners and D rings must be capable of supporting at least 5 000 lbf 22 2 kN Connectors must be compatible with the anchorage or other system components Do not use equipment that is not compatible Non compatible connectors may unintentionally disengage see Figure 5 Connectors must be compatible in size shape and strength If the connecting element to which a snap hook or cara...

Страница 9: ...eveals an unsafe or defective condition or if there is any doubt about its condition for safe use remove the Concrete Bolt Anchor from service immediately Clearly tag the system DO NOT USE See Section 5 for more information 4 2 FALL ARREST CONNECTIONS The Concrete Bolt Anchor is designed for use in several applications The connector is in compliance with ANSI Z359 18 Type A The product application...

Страница 10: ...nce or scheduled for maintenance should be tagged DO NOT USE These equipment tags should not be removed until maintenance is performed 6 1 CLEANING Periodically clean the Concrete Bolt Anchor s metal components with a soft brush warm water and a mild soap solution Ensure parts are thoroughly rinsed with clean water 6 2 SERVICE Only 3M or parties authorized in writing by 3M may make repairs to this...

Страница 11: ...the requirements of Table 1 Verify that the concrete is free of any cracks or damage Fall Protection Equipment Additional Fall Protection equipment that is used with the system should be installed and inspected per the manufacturer instructions Serial Number s Date Purchased Model Number Date of First Use Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintena...

Страница 12: ...quire product be returned to its facility for evaluation of warranty claims This warranty does not cover product damage due to wear abuse misuse damage in transit failure to maintain the product or other damage beyond 3M s control 3M will be the sole judge of product condition and warranty options This warranty applies only to the original purchaser and is the only warranty applicable to 3M s fall...

Отзывы: