3M DBI-SALA 2100041 Скачать руководство пользователя страница 1

© 3M 2020

USER INSTRUCTIONS

5902288 R

Ev

. E

ConCrete Bolt

Anchorage Connector

 

A

B

AnSI

oSHA

A

B

C

D

2104560

x1

x1

4.44 in.

(11.28 cm)

1.09 in.

(2.77 cm)

3.02 in.

(7.67 cm)

5.83 in.

(14.81 cm)

2104568

x1

x1

4.44 in.

(11.28 cm)

1.09 in.

(2.77 cm)

3.02 in.

(7.67 cm)

5.83 in.

(14.81 cm)

2100041

x0

x1

4.44 in.

(11.28 cm)

---

---

---

2100066

x0

x10

4.44 in.

(11.28 cm)

---

---

---

C

D

ANSI Z359.18

Type A

OSHA 1926.502

OSHA 1910.140

Содержание DBI-SALA 2100041

Страница 1: ...OSHA A B C D 2104560 x1 x1 4 44 in 11 28 cm 1 09 in 2 77 cm 3 02 in 7 67 cm 5 83 in 14 81 cm 2104568 x1 x1 4 44 in 11 28 cm 1 09 in 2 77 cm 3 02 in 7 67 cm 5 83 in 14 81 cm 2100041 x0 x1 4 44 in 11 28 cm 2100066 x0 x10 4 44 in 11 28 cm C D ANSI Z359 18 Type A OSHA 1926 502 OSHA 1910 140 ...

Страница 2: ...2 2 A C B D E F G H 3 4 C B A FC B C FC ...

Страница 3: ...A B C D E F G A B C 7 8 1 s s c c d 2 4 1 8 in 10 5 cm 18 mm 11 16 in 3 4 in 3 4 9 c 15 0 in 38 1 cm h 6 25 in 15 9 cm s 10 0 in 25 4 cm y 4 13 in 10 5 cm d 18mm 11 16 in 3 4 in 3000 psi 20 7 MPa h c s c y d ...

Страница 4: ... concrete Tighten bolt until red cap shears off No further adjustment is necessary after red cap shears off INSTALLATION Step 1 Step 2 Step 3 Step 4 Step 5 Concrete minimum compressive strength 3000 psi Not for use in lightweight concrete hollow block brick grout or stone 9501359 REV D Hole Depth 4 1 8 in INSPECTION Inspect anchor before each use Green seal on bolt head indicates proper installati...

Страница 5: ...ible and meet the requirements of applicable standards including the ANSI Z359 or other applicable fall protection codes standards or requirements Always consult a Competent or Qualified Person before using these systems CONCRETE ANCHORS Do not use device in wet or uncured concrete hollow block stone wood or other substrates or materials CONCRETE ANCHORS Prior to installation of device in an exist...

Страница 6: ...tified to ANSI Z359 18 2017 have also been tested in compliance with the requirements of ANSI Z359 7 ANSI compliance and testing covers only the product and does not extend to the anchorage structure or substrate to which the product is attached Anchorage Strength Structure must meet dimensional requirements from Figure 9 Anchorage strength must comply with Section 2 1 requirements If the user is ...

Страница 7: ...tached to an anchorage the strengths stated above must be multiplied by the number of systems attached to the anchorage See ANSI Z359 2 for more information 2 2 PERSONAL FALL ARREST SYSTEM Figure 1 illustrates the application of this Anchorage Connector Personal Fall Arrest Systems PFAS used with the system must meet applicable Fall Protection standards codes and requirements The PFAS must incorpo...

Страница 8: ...ty Connectors hooks carabiners and D rings must be capable of supporting at least 5 000 lbf 22 2 kN Connectors must be compatible with the anchorage or other system components Do not use equipment that is not compatible Non compatible connectors may unintentionally disengage see Figure 5 Connectors must be compatible in size shape and strength If the connecting element to which a snap hook or cara...

Страница 9: ...eveals an unsafe or defective condition or if there is any doubt about its condition for safe use remove the Concrete Bolt Anchor from service immediately Clearly tag the system DO NOT USE See Section 5 for more information 4 2 FALL ARREST CONNECTIONS The Concrete Bolt Anchor is designed for use in several applications The connector is in compliance with ANSI Z359 18 Type A The product application...

Страница 10: ...nce or scheduled for maintenance should be tagged DO NOT USE These equipment tags should not be removed until maintenance is performed 6 1 CLEANING Periodically clean the Concrete Bolt Anchor s metal components with a soft brush warm water and a mild soap solution Ensure parts are thoroughly rinsed with clean water 6 2 SERVICE Only 3M or parties authorized in writing by 3M may make repairs to this...

Страница 11: ...the requirements of Table 1 Verify that the concrete is free of any cracks or damage Fall Protection Equipment Additional Fall Protection equipment that is used with the system should be installed and inspected per the manufacturer instructions Serial Number s Date Purchased Model Number Date of First Use Corrective Action Maintenance Approved By Next inspection due Date Corrective Action Maintena...

Страница 12: ...quire product be returned to its facility for evaluation of warranty claims This warranty does not cover product damage due to wear abuse misuse damage in transit failure to maintain the product or other damage beyond 3M s control 3M will be the sole judge of product condition and warranty options This warranty applies only to the original purchaser and is the only warranty applicable to 3M s fall...

Отзывы: