General Operation
When the system is operating, one of two displays
will be shown. Pressing NEXT will alternate between
the displays. One of the displays is always the cur-
rent time of day. The second display is one of the
following: days remaining or gallons remaining. Days
remaining is the number of days left before the sys-
tem goes through a regeneration cycle. Capacity
remaining is the number of gallons that will be treated
before the system goes through a regeneration cycle.
The user can scroll between the displays as desired.
If the system has called for a regeneration that will
occur at the prest time of regeneration, the words
“REGEN TODAY” will appear on the display.
When water is being treated (i.e. water is flowing through the system) the word “SOFTENING” flashes on the display
if a water meter is installed.
User Display Settings
OR
REGEN TODAY will be
displayed if a regeneration
is expected “Tonight.”
Regeneration Mode
Typically a system is set to regenerate at a time of low
water usage. An example of a time with low water usage
is when members of a household are asleep. If there is a
demand for water when the system is regenerating, un-
treated water will be used.
Sometimes there is a need to regenerate the system
sooner than when the system calls for it, usually referred
to as manual regeneration. There may be a period of heavy
water usage because of guests or a heavy laundry day.
To initiate a manual regeneration at the present delayed regeneraton
time, press and release “REGEN”. The words “REGEN TODAY” will flash on the display to indicate that the
system will regenerate at the preset delayed regeneration time.
NOTE: If you pressed the "REGEN" button in error, pressing the button again will cancel the request.
To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin
to regenerate immediately. The request cannot be cancelled.
NOTE:
For softeners, if brine tank does not contain salt, fill with salt and wait at least two hours before regenerating.
When the system begins to regenerate, the display will change to include information about the step of the regeneration
process and the time remaining for that step to be completed. The system runs through the steps automatically and will
reset itself to help provide treated water when the regeneration has been completed.
Manual Regeneration
Set Time of Day
The user can also set the time of day. Time should only need
to be set after extended power outages or when daylight saving
time begins or ends. If an extended power outage occurs, the
time of day will flash on and off which indicates the time of day
should be reset.
Step 1 - Press SET CLOCK.
Step 2 - Current Time (hour): Set the hour of the day using
or button. AM/PM toggles after 12. Press NEXT to go to step 3.
Step 3 - Current Time (minutes): Set the minutes of the day
using or buttons. Press NEXT to exit Set Clock. Press
“REGEN” to return to previous step.
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
3-4