Step 10. Install OVERFLOW LINE to brine tank OVER-
FLOW FITTING (Figure 2). Discharge of line must
be lower than OVERFLOW FITTING.
DO NOT
INTERCONNECT OVERFLOW LINE WITH
VALVE DRAIN LINE.
Step 11. Make certain BYPASS VALVE INLET and OUT-
LET KNOBS ARE IN "BYPASS" position. After
all plumbing connections have been completed,
open main water shut-off valve or restore power to
well pump. Check for leaks and correct as
necessary.
Figure 4. BYPASS VALVE
Step 12. Plug CONTROL VALVE POWER CORD into 120v/
60Hz, non-switched power source. Manually stage
control to BACKWASH POSITION and then un-
plug power cord to prevent the unit from advancing
automatically.
Step 13. Partially open INLET knob on bypass valve (Figure 4).
This will allow the unit to fill slowly from the bottom
up, reducing air entrapment. Allow unit to fill
slowly, failure to do so could result in loss of resin to
the drain. Once a steady stream of water, no air,
is flowing to drain the inlet and outlet knobs on the
bypass can be fully opened.
Step 14. Refer to
Section 3: Regeneration Instructions,
on
how to set control valve for proper set up and regen-
eration
settings.
NOTE: Regeneration settings for the control valve
are factory preset. The control valve design permits
adjustment of the salt setting. This adjustment may
be necessary when unusual operating conditions
exist, such as high concentrations of iron, mang-
2-3
Some areas prohibit the use of flexible drain lines.
Check with local code officials prior to installation.
Figure 3. TYPICAL DRAIN
Step 8. Position DRAIN LINE over drain and secure firmly.
To prevent backsiphoning of waste water, provide
an air gap of at least 2 in. or 2 pipe diameters
between end of drain hose and drain (Figure 3).
DO
NOT
raise DRAIN LINE more than 10 ft. above floor.
Step 9. Connect one end of the 3/8 in. black Polyethylene
tubing to the brine fitting located on the left side of
the CONTROL VALVE. Connect the other end to
the SAFETY BRINE VALVE ELBOW inside of the
brine well in the brine tank. To do so remove the
retaining clip from the brine line fitting on the control
valve. The retaining clip is holding a plastic insert
sleeve and needs to be inserted into the polyethylene
tubing before installing the tubing into the fitting
elbow and hand tighten only.
CAUTION: Do not
use pliers or wrenches to tighten the fitting as
damage may occur and will void the manu-
facturer’s
warranty.
anese or hardness and/or high flow rates or
daily water consumption.
BYPASS VALVE
IN
OUT
CONTROL VALVE BODY
DRAIN LINE FLOW
CONTROL ASSEMBLY
BRINE LINE
ELBOW
INJECTOR COVER
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Supply Water
Enters
Supply (Untreated)
Water Exits
Supply Water
Enters
Treated Water
Exits
NORMAL OPERATION