3M Crimplok 8702-UPC Скачать руководство пользователя страница 15

78-0015-0557-3-B 

15 

5.9 

Before the network has a laser light source feeding 
your connector, inspect the fiber end face with 
3M™ 200X View Scope 6365-VS if you have one. 
If the fiber end face looks acceptable per photos to 
the right, then protect it with a dust cap, or insert 
into its adapter. If the connector needs rework, 
proceed to Section 6.0. 

 
Caution reminder: Never look directly into the end of a 
fiber or connector when connected to a laser light source 
using the naked eye or a microscope. 

Chips or cracks inside the ½ diameter circle are not allowed 

Acceptable chip 

Unacceptable chip, 

needs rework 

Unacceptable crack, 

needs rework 

Dirty, needs 

cleaning 

Alcohol on fiber, 

re-dry 

Alcohol on 

ferrule, re-dry 

Thread caught, re-

clean with a twist 

UPC only photo: forgot 

to spray water, needs 

rework 

Forgot to use lapping 

film, needs rework 

Thin black line is visible 

Ideal, clean fiber end face 

Light grey 

Dark grey 

No line, just grey to white 

Fiber is missing, go to step 6.1 

Cleave nick mark 

Rough 

edge 

Not polished, restart at step 5.1 

Содержание Crimplok 8702-UPC

Страница 1: ...3M Crimplok SC Connector for 1 6 3 mm cable 8702 UPC APC SM 6702 50 50 m MM 6702 50 LOMMF 50 m MM 6702 62 5 62 5 m MM Instructions October 2014 78 0015 0557 3 B...

Страница 2: ...s are sharp and can pierce the skin Use tweezers when handling shards and dispose of them properly per your company health and safety instructions CAUTION Fiber Cable Handling To reduce the risk assoc...

Страница 3: ...8765 T PS UPC for 8700 UPC 8702 UPC 6700 and 6702 8765 T PS APC for 8700 APC and 8702 APC C 3M Crimplok SC Nano Finishing Tool 8765 NF UPC or 8765 NF APC D 3M green Lapping Film for APC 3M white Lappi...

Страница 4: ...environmental information given on product labels or the Material Safety Data Sheets for isopropyl alcohol fiber optic cleaning fluid and or methanol water solution 1 4 Optional accessory 3M 200X View...

Страница 5: ...able holder underneath the screw head The screw head can hold the cable holder in place 3 3 For the Ilsintech CI 01 cleaver only open the right cover on the cleaver Move the blade carriage to the fron...

Страница 6: ...ack on the cable holder Align the beginning of the cable slit with the 2 posts at the beginning of the cable track 3 6 Close the back lid until it latches shut 3 7 Arrange the slit jacket along the si...

Страница 7: ...he cable holder fork is longer than the other Use the longer of the two as a target Also strip any 250 m coating left behind Note Do not grip the fiber stripper with full strength because it can damag...

Страница 8: ...or cleaning fluid 3 13 Open the cover s on the cleaver Once per day or whenever the cleaver gets dirty clean the fiber groove and rubber pad s with a cleaning swab Do not touch the diamond wire on th...

Страница 9: ...a stop Gently pull back on the cable holder about 1 mm release it and watch it spring forward into place This indicates you are ready for the next step If the cable holder did not click or does not sp...

Страница 10: ...the fiber backward 4 6 Press down hard on the free end of the activation lever to activate the fiber crimping mechanism within the connector After a click sound the lever will be stopped and cannot b...

Страница 11: ...0 m fiber before the nut and boot are attached If needed the 900 m buffer strain relief can be deactivated carefully with a tweezers 4 8 Rotate the protrusion setting lever up Lift the front 2 covers...

Страница 12: ...the fiber is not bowed 4 13 Hold the aramid yarn straight in a bundle on underside of connector as shown in photo Lightly pull jacketed cable ensuring bow is fully removed Aramid yarn should be straig...

Страница 13: ...ishing surface while pressing the disc down 5 2 Wet the top surface of the finishing disc with 2 squirts of de ionized or distilled water using the spray bottle provided Avoid using excessive amounts...

Страница 14: ...he connector so the ferrule tip is in full contact with the wipe For UPC hold the connector perpendicular to the wipe Press the ferrule tip into the wipe slightly and move the tip in a circular motion...

Страница 15: ...ctor when connected to a laser light source using the naked eye or a microscope Chips or cracks inside the diameter circle are not allowed Acceptable chip Unacceptable chip needs rework Unacceptable c...

Страница 16: ...nd reinsert the cable into the fiber holder beginning in Step 3 5 7 0 Troubleshooting 7 1 If the cable holder does not spring forward in step 4 2 then remove the cable holder from the protrusion setti...

Страница 17: ...65 T UPC Crimplok Termination Kit for SC UPC SM and MM Connectors 250 900 m 1 6 3 mm Cable 1 package 8765 T APC JKT Crimplok APC Protrusion Setting Tool 1 6 3 mm Cable Holder and cable slitter tools 1...

Страница 18: ...which are not contained in 3M s current publications or any contrary statements contained on your purchase order shall have no force or effect unless expressly agreed upon in writing by an authorized...

Отзывы: