background image

This respirator can help reduce inhalation exposures to certain 

airborne biological particles (e.g. mold, Bacillus anthracis, 

Mycobacterium tuberculosis, etc.) but cannot eliminate the 

risk of contracting infection, illness or disease. OSHA and other 

government agencies have not established safe exposure limits for 

1.  Failure to follow all instructions and limitations on the use of this 

respirator and/or failure to wear this respirator during all times of 

may result in 

2.  In the U.S., before occupational use of this respirator, a written 

respiratory protection program must be implemented meeting 

all the requirements of OSHA 29 CFR 1910.134 such as training, 

fit testing, medical evaluation, and applicable OSHA substance 

specific standards. In Canada, CSA standard Z94.4 requirements 

must be met and/or requirements of the applicable jurisdiction, 

3.  The particles which can be dangerous to your health include 

4.  Leave the contaminated area immediately and contact 

5.  Store the respirator away from contaminated areas when not 

Содержание 8511

Страница 1: ...PORTANT Keep these User Instructions 07185 is a catalog number only NIOSH approved as 3M 8511 Particulate Respirator N95 See insert for approval label IMPORTANTE Conserve estas Instrucciones para referencia futura See insert for approval label Consulte la etiqueta de aprobación en el inserto 98 0060 0125 3_3 ...

Страница 2: ...casionar enfermedad o incluso la muerte Para su uso adecuado consulte a su supervisor lea las Instrucciones o llame a 3M en EUA al 1 800 247 3941 In En Canadá llame al Servicio Técnico al 1 800 267 4414 En México llame al 01 800 712 0646 o contacte a 3M en su país Website www 3M com PPESafety Technical Assistance 1 800 243 4630 For other 3M products 1 800 3M HELPS or 1 651 737 6501 PARA OBTENER MÁ...

Страница 3: ...se consult the 3M Respirator Selection Guide found on the 3M Personal Safety Division web site at www 3M com PPESafety or call 1 800 243 800 267 4414 Do not use for gases and vapors oil aerosols asbestos or sandblasting particulate concentrations that exceed either 10 times the occupational exposure limit or applicable government regulations whichever is lower In the U S do not use when the Occupa...

Страница 4: ... to wear this respirator during all times of may result in 2 In the U S before occupational use of this respirator a written respiratory protection program must be implemented meeting all the requirements of OSHA 29 CFR 1910 134 such as training fit testing medical evaluation and applicable OSHA substance specific standards In Canada CSA standard Z94 4 requirements must be met and or requirements ...

Страница 5: ... inspected prior to each use to assure there are no holes in the breathing zone other than the punctures around staples and no damage has occurred Enlarged holes resulting from ripped or torn filter material around staple punctures are considered damage Immediately NIOSH approval 7 Conduct a user seal check before use as specified in the Fitting Instructions section If you cannot achieve a proper ...

Страница 6: ...ng 5 Respirators can help protect your lungs against certain airborne contaminants They will not prevent entry through other routes such as the skin which would require additional personal 6 This respirator is designed for occupational professional use by adults who are properly trained in their use and limitations This 7 Individuals with a compromised respiratory system such as asthma or emphysem...

Страница 7: ... humidity conditions specified the product may be used until the use by date specified on packaging Always inspect product and conduct a user seal check before use as specified in User Instructions If you cannot achieve End of Shelf Life Use respirators before the use by date specified Storage Temperature Range 20 C If respirator becomes damaged soiled or breathing becomes respirator 86 F 30 C 4 F...

Страница 8: ...d the nose area to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece Fig 3 Pinching the nosepiece using one hand may result in 4 Perform a User Seal Check prior to each wearing To check the respirator to face seal place both hands completely over the respirator and inhale sharply Be careful not to disturb the position of the respirator A negativ...

Страница 9: ... step 2 of Fitting Instructions and cup respirator in hand to maintain position on face Pull bottom strap over head Still holding respirator in position pull top strap over head and Fig 1 Fig 2 Fig 3 Fig 4 ...

Страница 10: ... uso de 3M para esta clase de respirador favor de consultar la Guía de selección de respiradores 3M en el sitio de la División de Seguridad Personal www 3M com PPESafety o llame a 3M en EUA al 1 800 243 4630 En Canadá llame al 1 800 267 4414 En México llame al 01 800 712 No use para gases y vapores aerosoles de aceite asbestos o sandblasteo concentraciones de partículas que excedan gubernamentales...

Страница 11: ...tividad de éste y ocasionar enfermedad o incluso la muerte 2 Antes del uso ocupacional de este respirador en Estados Unidos debe implantarse un programa escrito de protección respiratoria que cumpla con todos los requerimientos de la norma OSHA 29 CFR 1910 134 como capacitación prueba de ajuste evaluación médica y las normas aplicables específicas de substancias de OSHA En Canadá se debe cumplir c...

Страница 12: ...so para asegurarse que no tengan hoyos en la zona de respiración distintas a los hoyos alrededor de las grapas o que no haya algún otro daño Los hoyos agrandados ocasionados por rasgaduras o roturas del material de filtración alrededor de los hoyos de las grapas se consideran como un daño Reemplace de inmediato el respirador si está dañado Las perforaciones de grapas no afectan la aprobación del N...

Страница 13: ...es pueden ayudar a proteger los pulmones contra ciertos contaminantes suspendidos en el aire sin embargo no evitarán la entrada de estos por medio de otras vías como la piel lo que requerirá el uso de equipo de protección personal 6 Este respirador está diseñado para uso ocupacional profesional por adultos capacitados adecuadamente en su uso y limitaciones Este respirador no está diseñado para su ...

Страница 14: ...puede utilizar hasta la fecha especificada en el empaque Antes de utilizar el producto verifíquelo y realice una prueba del sello como se indica en las Instrucciones Fin de vida de anaquel Use los respiradores antes de la fecha usar hasta Rango de temperatura de almacenamiento 20 C Humedad relativa máxima de almacenamiento Abandone de inmediato el área contaminada si el respirador se Debe seguir e...

Страница 15: ...ea nasal a la forma de su nariz empujando hacia dentro mientras mueve las puntas de los dedos hacia abajo en ambos lados de la pieza nasal Fig 3 Si presiona la pieza nasal con una mano es posible que logre un mal ajuste y el desempeño del respirador sea menos 4 Antes de cada uso realice una revisión del sello Para revisar el sello facial del respirador coloque ambas manos sobre el respirador e inh...

Страница 16: ...el paso 2 de las instrucciones de ajuste y coloque el respirador en la mano para mantener la posición en la cara Jale la banda inferior sobre su cabeza Con el respirador en posición jale Fig 1 Fig 2 Fig 3 Fig 4 ...

Страница 17: ...TECTION N95 Particulate Filter 95 filter efficiency level effective against particulate aerosols free of oil time use restrictions may apply M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the O Refer to user s Instructions and or mai...

Страница 18: ... 1000 1 800 494 3552 Made in U S A with US and For more information in www 3M com ppesafety R F C TMM 2014 3M Todos los Fabricado en EE UU con Para más información en www 3M com ppesafety ...

Страница 19: ......

Страница 20: ......

Страница 21: ......

Отзывы: