7800 - Disassembly 

© 3M June 2006.  All rights reserved. 

11)  The 7914 is the Band Clamp.

 Replace the clamp when it is distorted or 

damaged. To remove it:

 

 

a.  Untighten and loosen the screw on the clamp with a Phillips head 

screwdriver: 

 

b.  Remove the clamp. 

 

12) 

The 7881 and 7981 Small-Size are the Nose Cup Assemblies.

 They 

include the 7882 Nose Cup Valve Assembly. Replace the nose cup 
when it is damaged or distorted. To remove it: 

 

a.  Pull it away from the facepiece. 

 

b.  To remove the 7882 Valve Assembly, push it out of the nose cup. 

 

13)  The 7916 is the Breathing Room Assembly.

 Replace the assembly 

when it is dirty or damaged. To remove it:

 

 

a.  Remove the breathing room from the front of the facepiece by 

pulling up while twisting. 

 

14)  The 7895 is the Speaking Diaphragm Kit.

 Replace the kit when it is 

damaged or does not seat properly. To remove it:

 

 

a.  Use the diaphragm removal tool to turn the diaphragm retaining 

ring counterclockwise and remove. 

 

b.  Push the diaphragm out of the facepiece from underneath using the 

eraser end of a pencil or similar object. 

 

15)  The 7282 is the Inhalation Valve.

 Replace it if warped, distorted, cut, 

split or will not seat properly. To remove it:

 

 

a.  Locate the valve on the posts inside the facepiece. 

 

b.  Lift the valve from the valve seat. 

 

c.  The 7886 is the DIN Connector. Do not replace the connector 

unless it is damaged. If it must be removed call 3M Technical 
Service at 1-800-243-4630. 

 