SPERIAN

SURVIVAIR Opti-Fit

S-Series

Full Facepiece Air Purifying Respirator

Operation and Maintenance Manual

WARNING

DO NOT USE this respirator until you completely read and understand 

this instruction manual. You are required to inspect the respirator pri-

or to putting it into field service. Please refer to the inspection proce

-

dures in this manual. Failure to comply with this warning may result in 

personal injury, illness, or death.

NIOSH APPROVED—SEE SEPARATE APPROVAL LABEL

AN ISO 9001

REGISTERED

COMPANY

©

Copyright July 2008 All Rights Reserved

SPERIAN Respiratory Protection USA, LLC

P/N 622094 Rev. G 03/09

SPERIAN Respiratory Protection USA, LLC

3001 South Susan St., Santa Ana, CA 92704

Toll-Free 888.APR.SCBA or 714.545.0410

Fax 714.850.0299

www.sperianprotection.com

Содержание SURVIVAIR Opti-Fit S-Series

Страница 1: ...service Please refer to the inspection proce dures in this manual Failure to comply with this warning may result in personal injury illness or death NIOSH APPROVED SEE SEPARATE APPROVAL LABEL AN ISO 9...

Страница 2: ...FIT CHECK THE RESPIRATOR 13 A Positive Pressure Fit Check 13 B Negative Pressure Fit Check 13 VIII HOW TO USE THE RESPIRATOR 14 IX HOW TO DOFF THE RESPIRATOR 14 X CHEMICAL CARTRIDGE SERVICE LIFE AND R...

Страница 3: ...ce of these respirators P NIOSH does not evaluate respirators for use as surgical masks S Special or critical User s Instructions and or specific use limitations apply Refer to User s Instructions bef...

Страница 4: ...e endangered in any way through environmentally induced degradation of the materials in the apparatus All persons using this Sperian breathing apparatus must be made aware of its limitations We cannot...

Страница 5: ...contaminants and selecting appropriate respirators procedures for proper use of respirators pro cedures for testing the facepiece to face fit of respirators procedures for cleaning disinfecting inspe...

Страница 6: ...shold Limit Value TLV or the NIOSH Recommended Exposure Limits REL Many chemicals e g isocyanates mercury etc have no physical warning properties and you cannot taste or smell the contaminants even th...

Страница 7: ...10 702037 Twin Seal 10 Pkg of 4 B140005 Exhalation Valve 11 1 820261 O ring 12 1 702003 Nozzle 13 1 702004 Cover 14 2 962090 Valve Holder 15 1 702023 Nose Cup 16 2 702016 Short Buckle Strap TPE 17 3 7...

Страница 8: ...x of 100 702031 Neckstrap Kit 702030 Headstrap Kit Black Silicone 702031 Neckstrap Kit 702090 Headnet Kit NOTE Use only components with the part numbers listed on the NIOSH approval label Use of any o...

Страница 9: ...cid Gases 9 Figure 2 Opti Fit APR with Headnet Figure 2 Opti Fit APR with Headnet Table 1 Cartridges and Filters Threaded Style See NIOSH Approval Label for Specific Contaminants MODEL FILTERS 1050 P1...

Страница 10: ...90 P100 Slimline MODEL CARTRIDGES 7801 Organic Vapors 7802 Acid Gases 7803 Organic Vapors and Acid Gases 7804 Ammonia and Methylamine 7808 Multi contaminant 7851 Combination Organic Vapors and P100 78...

Страница 11: ...used within 30 days Never enter or remain in a hazardous atmosphere if one or more of the ESLIs is gray B Particulate Filters Before using a particulate filter you must confirm the atmosphere is non...

Страница 12: ...ng contact with the retainer and the filter is not bunched or folded The outer edge of the pad must be compressed between the top edge of the cartridge or filter holder and the inner sealing rings of...

Страница 13: ...e Pressure Fit Check Hold the palm of your hand gently over the exhalation valve outlet of the nozzle cover Do not distort the natural shape of the facepiece Exhale gently and hold your breath to crea...

Страница 14: ...upward over the head X CHEMICAL CARTRIDGE SERVICE LIFE AND REPLACEMENT The cartridge service life depends on the user s breathing rate the characteristics of the contaminant and environmental conditi...

Страница 15: ...eck as described in section VII XII MAINTENANCE A Inspection Inspect this respirator as described in section XIII for defects before and after each use and at least monthly if not used Repair as neces...

Страница 16: ...r may be used to speed up drying NOTE Washing the lens will remove any user applied anti fog coating Recoat with Sperian Anti fog solution P N 951015 1 oz or 951016 16 oz or use Sperian single use ant...

Страница 17: ...ir and before respirator use XV STORAGE After inspection and cleaning store your SURVIVAIR Opti Fit facepiece to protect it against dust sunlight extreme heat and cold excessive moisture or damaging c...

Страница 18: ...HANTABILITY OR FITNESS FOR A PARTICU LAR PURPOSE CONDITIONS To maintain this warranty this product must be used maintained and inspected as prescribed in the owner s instruction manual including promp...

Страница 19: ...Abrasions or nicks 2 Deterioration from age heat or contamination FACEPIECE BUCKLES Crushed bent broken or corroded FACEPIECE INLET NOZZLE 1 Heat or impact damage 2 Nicks cracks tears or creases in t...

Страница 20: ...ot use the o ring if it is damaged 4 Place the o ring into the groove on the lens with the part number tab aligned with the slot 5 Align the three lugs on the underside of the connector with the three...

Страница 21: ...e lens edge inside the lens channel of the skirt 12 Knead the skirt until the silicone fits evenly around the lens edge 13 Install the rims Start the screw on one side then the other CAUTION Do not pi...

Страница 22: ...22 www sperianprotection com...

Отзывы: