WARNING—Continued

sensitizers. Use positive pressure supplied air respirators to provide 

better  protection  from  these  chemicals.  Do  not  use  this  respirator  if 

you have been sensitized from previous exposure or believe that you 

may be sensitive or allergic to any chemical (e.g., isocyanates, latex, 

etc.) until you obtain clearance from a medical doctor.

• Use of components other than those listed on the NIOSH approval label 

and in this manual, or as authorized by Sperian, or modification of this 

respirator in any manner will void the NIOSH certification and invali

-

dates all Sperian’s warranties for the respirator.

•  Always  read  and  follow  the  instructions  listed  in  the  Material  Safety 

Data Sheet for the chemicals that are present in the work area.

•  Do not use if you have a preexisting skin condition (for example, follicu

-

litus or vitiligo) until you obtain clearance from a medical doctor.

• This respirator must be worn and used as specified in Sperian’s instruc

-

tions.  No  respirator  can  provide  complete  protection  from  all  condi

-

tions. Use extreme care for emergency conditions.

•  Some individuals are sensitive to chemicals (e.g., isocyanates, latex, oil 

mists, etc.) or may have some type of respiratory disorder (e.g. asthma, 

chronic  obstructive  airway  disease,  etc.).  If  you  are  sensitive  to  any 

chemical or have a respiratory disorder, you may have a severe reac

-

tion at contaminant levels well below accepted health levels, such as 

the OSHA Permissible Exposure Limit (PEL), ACGIH

®

 Threshold Limit 

Value (TLV), or the NIOSH Recommended Exposure Limits (REL). Many 

chemicals (e.g., isocyanates, mercury, etc.) have no physical warning 

properties and you cannot taste or smell the contaminants even though 

they may be present in the respirator facepiece. This respirator will re-

duce, but will not eliminate the possibility of contaminants entering the 

facepiece and causing a severe reaction. Do not use this respirator un

-

til you obtain clearance from a medical doctor.

•  Do not alter or modify any respiratory product.

•  If this respirator will be used during welding, it is the user’s responsibil

-

ity to obtain the proper equipment for protection against sparks, optical 

radiation, and impact. This respirator will not protect you against these 

hazards.

•  Users must clean and maintain this respirator only in accordance with 

Sperian’s  instructions.  Accessories  not  offered  by  Sperian  may  de

-

grade performance, and will void NIOSH certification.

• The respirator facepiece assembly contains natural rubber latex which 

may cause allergic reactions in some individuals. Discontinue use if 

you experience an allergic reaction.

•  Discontinue use if you experience skin irritation or discoloration.

• This product may provide less than adequate protection if improperly 

used, which may result in personal injury, illness, or death.

•  For use by trained, qualified personnel only.

•  Routinely  used  respirators  must  be  inspected  before  and  after  each 

use. Stored emergency respirators must be inspected after each use 

and at least once every 30 days. A written record must be kept of in

-

spections of emergency respirators.

• FAILURE TO OBSERVE ALL WARNINGS MAY RESULT IN PERSONAL 

INJURY, ILLNESS, OR DEATH.

Содержание SURVIVAIR Opti-Fit S-Series

Страница 1: ...service Please refer to the inspection proce dures in this manual Failure to comply with this warning may result in personal injury illness or death NIOSH APPROVED SEE SEPARATE APPROVAL LABEL AN ISO 9...

Страница 2: ...FIT CHECK THE RESPIRATOR 13 A Positive Pressure Fit Check 13 B Negative Pressure Fit Check 13 VIII HOW TO USE THE RESPIRATOR 14 IX HOW TO DOFF THE RESPIRATOR 14 X CHEMICAL CARTRIDGE SERVICE LIFE AND R...

Страница 3: ...ce of these respirators P NIOSH does not evaluate respirators for use as surgical masks S Special or critical User s Instructions and or specific use limitations apply Refer to User s Instructions bef...

Страница 4: ...e endangered in any way through environmentally induced degradation of the materials in the apparatus All persons using this Sperian breathing apparatus must be made aware of its limitations We cannot...

Страница 5: ...contaminants and selecting appropriate respirators procedures for proper use of respirators pro cedures for testing the facepiece to face fit of respirators procedures for cleaning disinfecting inspe...

Страница 6: ...shold Limit Value TLV or the NIOSH Recommended Exposure Limits REL Many chemicals e g isocyanates mercury etc have no physical warning properties and you cannot taste or smell the contaminants even th...

Страница 7: ...10 702037 Twin Seal 10 Pkg of 4 B140005 Exhalation Valve 11 1 820261 O ring 12 1 702003 Nozzle 13 1 702004 Cover 14 2 962090 Valve Holder 15 1 702023 Nose Cup 16 2 702016 Short Buckle Strap TPE 17 3 7...

Страница 8: ...x of 100 702031 Neckstrap Kit 702030 Headstrap Kit Black Silicone 702031 Neckstrap Kit 702090 Headnet Kit NOTE Use only components with the part numbers listed on the NIOSH approval label Use of any o...

Страница 9: ...cid Gases 9 Figure 2 Opti Fit APR with Headnet Figure 2 Opti Fit APR with Headnet Table 1 Cartridges and Filters Threaded Style See NIOSH Approval Label for Specific Contaminants MODEL FILTERS 1050 P1...

Страница 10: ...90 P100 Slimline MODEL CARTRIDGES 7801 Organic Vapors 7802 Acid Gases 7803 Organic Vapors and Acid Gases 7804 Ammonia and Methylamine 7808 Multi contaminant 7851 Combination Organic Vapors and P100 78...

Страница 11: ...used within 30 days Never enter or remain in a hazardous atmosphere if one or more of the ESLIs is gray B Particulate Filters Before using a particulate filter you must confirm the atmosphere is non...

Страница 12: ...ng contact with the retainer and the filter is not bunched or folded The outer edge of the pad must be compressed between the top edge of the cartridge or filter holder and the inner sealing rings of...

Страница 13: ...e Pressure Fit Check Hold the palm of your hand gently over the exhalation valve outlet of the nozzle cover Do not distort the natural shape of the facepiece Exhale gently and hold your breath to crea...

Страница 14: ...upward over the head X CHEMICAL CARTRIDGE SERVICE LIFE AND REPLACEMENT The cartridge service life depends on the user s breathing rate the characteristics of the contaminant and environmental conditi...

Страница 15: ...eck as described in section VII XII MAINTENANCE A Inspection Inspect this respirator as described in section XIII for defects before and after each use and at least monthly if not used Repair as neces...

Страница 16: ...r may be used to speed up drying NOTE Washing the lens will remove any user applied anti fog coating Recoat with Sperian Anti fog solution P N 951015 1 oz or 951016 16 oz or use Sperian single use ant...

Страница 17: ...ir and before respirator use XV STORAGE After inspection and cleaning store your SURVIVAIR Opti Fit facepiece to protect it against dust sunlight extreme heat and cold excessive moisture or damaging c...

Страница 18: ...HANTABILITY OR FITNESS FOR A PARTICU LAR PURPOSE CONDITIONS To maintain this warranty this product must be used maintained and inspected as prescribed in the owner s instruction manual including promp...

Страница 19: ...Abrasions or nicks 2 Deterioration from age heat or contamination FACEPIECE BUCKLES Crushed bent broken or corroded FACEPIECE INLET NOZZLE 1 Heat or impact damage 2 Nicks cracks tears or creases in t...

Страница 20: ...ot use the o ring if it is damaged 4 Place the o ring into the groove on the lens with the part number tab aligned with the slot 5 Align the three lugs on the underside of the connector with the three...

Страница 21: ...e lens edge inside the lens channel of the skirt 12 Knead the skirt until the silicone fits evenly around the lens edge 13 Install the rims Start the screw on one side then the other CAUTION Do not pi...

Страница 22: ...22 www sperianprotection com...

Отзывы: