3.0 Install Lug or Connector
3.1 Check to be sure the cable fits within the kit ranges as shown in Table 1.
3.2 Position lug/connector and crimp according to manufacturer’s directions. Remove excess oxide inhibitor and
sharp crimp flashing following crimping. Refer to page 14 for 3M lug/connector crimping information up to
1000 kcmil.
4.0 Clean Cable Insulation and Lug Barrel Using Standard Practice
4.1 Use only aluminum oxide abrasive to finish and polish insulation surface.
4.2 Use abrasive only on cable insulation.
Do not use on semi-con.
4.3 When using abrasive, do not reduce the cable insulation diameter below that allowed by the kit.
4.4 Wipe the cable insulation clean with an approved solvent.
Do not allow the solvent to touch semi-con
insulation shield.
Note: Remove any remaining solvent with 3M
™
CC-DRY Cable Cleaning Pads (not supplied with kit) or