Important Notice:

All statements, technical information, 
and recommendations related to 3M’s
products are based on information 
believed to be reliable, but the accuracy 
or completeness is not guaranteed. Before
using this product, you must evaluate it and
determine if it is suitable for your intended
application.You assume all risks and
liability associated with such use. Any
statements related to the product which is
not contained in 3M’s current publications,
or any contrary statements contained on
your purchase order shall have no force 
or effect unless expressly agreed upon, 
in writing, by an authorized officer of 3M. 

Warranty; Limited Remedy; Limited
Liability.

This product will be free from defects 
in material and manufacture for a period 
of one year from the time of purchase. 

3M MAKES NO OTHER WARRANTIES
INCLUDING, BUT NOT LIMITED TO,
ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE.

If this product is defective within the
warranty period stated above, your
exclusive remedy shall be, at 3M’s option,
to replace or repair the 3M product or
refund the purchase price of the 3M
product. 

Except where prohibited by 

law, 3M will not be liable for any indirect,
special, incidental or consequential loss
or damage arising from this 3M product,
regardless of the legal theory asserted.

Litho in USA

© 3M 2002

34-7051-6227-8

Recycled paper
40% pre-consumer waste paper
10% post-consumer waste paper

Содержание 718

Страница 1: ...fying the operation of air ionizers by measuring the neutralization time for a static charge placed on a stationary metal plate Any deviation from this intended use could impair the instrument s effec...

Страница 2: ......

Страница 3: ...lied by a 9V alkaline battery 2 2 To install the battery on either unit 2 2 1 Remove the battery cover located in the lower back of the unit To do this press down on the cover and slide it downward 2...

Страница 4: ...ront of the sensor are lit To shut off the 718 Static Sensor momentarily press down on the membrane switch labeled POWER Determining that the power is off can be verified by seeing that the liquid cry...

Страница 5: ...ight emitting diodes LED s are present on the front face of the instrument These LED s emit two red bullseye targets on the surface of the object being measured As the instrument gets closer to the on...

Страница 6: ...disabled The Automatic Shut Off feature will reset itself the next time the instrument is turned on 4 0 Operation and Use of the 718A Air Ionizer Test Kit It is recommended that the user be familiar...

Страница 7: ...er s operating manual or consult with the ionizer manufacturer to determine what this offset balance should be 5 0 Service Calibration 5 1 Service and Repair in the event that you believe the 718 Stat...

Страница 8: ...he stand to ground 5 5 3 Turn on the 718 Static Sensor and set it to the 2 kV range 5 5 4 Ground the plate Zero the display 5 5 5 Remove the ground from the plate and connect it to the high voltage po...

Страница 9: ...ge Automatic Shut off 20 minutes after last switch activity Operating Time for Battery Greater than 50 hours with new battery 21 C Continuous usage Distance Indicator LED targets Aligned targets indic...

Страница 10: ...ual 1 ea Certificate of Conformance 8 0 Contact Information Customer and Technical Service Within the U S Customer service and technical support can be obtained by calling the 3M Electronic Handling P...

Страница 11: ......

Страница 12: ...less expressly agreed upon in writing by an authorized officer of 3M Warranty Limited Remedy Limited Liability This product will be free from defects in material and manufacture for a period of one ye...

Отзывы: