39
Flush Table: HF20-I, HF20-SI
Head & Manifold
# of
Cartridges
Rated Flow
Flush Instructions
High Flow Series
Twin 2XX Manifold
2
3.34 gpm
(12,6 lpm)
Flush 6.67 gallons (25,2 liters)
through cartridge(s) before use
(flush approx. 2 mins.)
High Flow Series
Triple 3XX Manifold
3
5 gpm
(18,9 lpm)
Flush 10.0 gallons (37,9 liters)
through cartridge(s) before use
(flush approx. 2 mins.)
Flush Table: HF25-S-SR
2
, HF20-A020-SR, HF20-S-SR, HF20-A020-S-SR
Head & Manifold
# of
Cartridges
Rated
Flow
Flush Instructions
High Flow Series
Twin 2XX Manifold
2
4 gpm
(15,1 lpm)
Flush 8.0 gallons (30,3 liters) through
cartridge(s) before use (flush approx. 2
mins.)
High Flow Series
Triple 3XX Manifold
3
6 gpm
(22,7 lpm)
Flush 12.0 gallons (45,4 liters) through
cartridge(s) before use (flush approx. 2
mins.)
Flush Table: HF30
1
, HF30-MS
1
, HF35-CL
1
, HF35
1
, HF35-MS
1
Head & Manifold
# of
Cartridges
Rated
Flow
Flush Instructions
High Flow Series
Twin 2XX Manifold 2
3.34 gpm
(12,6 lpm)
Flush 6.67 gallons (26,5 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series
Triple 3XX Manifold 3
5 gpm
(18,9 lpm)
Flush 10.5 gallons (39,75 liters) through
cartridge(s) before use (flush approx. 2 mins.)
Flush Table: HF40
1
, HF40-S
1
, HF45
1
, HF45-S
1
Head & Manifold
# of
Cartridges
Rated
Flow
Flush Instructions
High Flow Series
Twin 2XX Manifold 2
4.2 gpm
(15,9 lpm)
Flush 8.4 gallons (31,8 liters) through
cartridge(s) before use (flush approx. 2 mins.)
High Flow Series
Triple 3XX Manifold 3
6.3 gpm
(23,8 lpm)
Flush 12.6 gallons (47,7 liters) through
cartridge(s) before use (flush approx. 2 mins.)
System has been tested and certified by NSF International against NSF/ANSI Standard 42, 53
and/or CSA B483.1 for the reduction of the substances specified on the Performance Data Sheet.
COMPONENT
This cartridge is Tested and Certified by NSF International against NSF/ANSI Standard 42 for
materials and structural integrity requirements.
This model is certified by the
Water Quality Association to
WQA/ASPE/ANSI S-803
for Sustainability.
This model is certified by the Water Quality Association to WQA/ASPE/ANSI S-803 for
Sustainability.
1
This model is not certified by WQA to WQA/ASPE/ANSI S-803.
2
NSF COMPONENT Listing