G.   INSTALL THE FEED WATER CONNECTION AND TUBING 

1)  Open faucet and turn off cold water supply to relieve pressure. 

2)  Locate the cold water stem on the underside of the faucet fixture. 

Unscrew the cold water feed tube from the faucet stem. Locate the 

Faucet Adapter that came with your drinking water system. Insert 

the black gasket into the threaded adapter and tighten onto the 

Faucet Cold Water Stem under the sink, making sure that 1/4” side 

connection is accessible and not facing the wall. Make sure not to 

overtighten.

3)  Take the Cold Water Feed Tube and attach to the Faucet Adapter, 

making sure not to over tighten.

4)  Locate the 1/4” Orange Tubing and insert into the 1/4” outlet of 

Faucet Adapter.  See Figure 3 and “Using Push-in Fittings” below.

5)  Leave cold water supply off. 

H.   PREFILL AND SANITIZE THE STORAGE TANK

 

Prefilling the storage tank is always recommended so that there is 

pressure to check for leaks as well as sufficient water to flush the carbon 

block post-filter. It is important to use a sanitizer when prefilling the tank 

so the solution can sanitize the tubing, fittings, and the faucet at start up.

1) 

Remove protective cover from storage tank and discard.  Using an 

eye dropper, dispense 2 drops of ordinary household bleach into the 

end of the tank. Apply PTFE tape (not included) to threaded tank 

connection and install tank valve onto connection. 

Do not over 

tighten. 

Open the tank valve so that the tank valve handle is parallel 

to the valve body. 

2)

  Connect one end of the 3/8” yellow tubing into quick connect tank 

valve. Connect the other end of the 3/8” yellow tubing to the included 

3/8” x 1/4” union connector.

3)

  Connect the free end of the 1/4” orange feedwater tubing to the other 

end of the 3/8” x 1/4” union connector.

4)

  Open the cold water supply (making sure the tank valve is still open) 

and allow the tank to fill (about 3 minutes).

5)

  Close the cold water supply and the tank valve.  Disconnect the orange 

and yellow tube from the union connector, setting the tank aside while 

proceeding with the rest of the installation (the sanitizing solution 

should be kept in the tank for at least 15 minutes).  Refer to the “Using 

Push-In Fittings” section.

NOTE: 

 If you encounter difficulty in removing the tubing from the 3/8” x 

1/4” union connector, 

make sure the tank 

valve is closed and 

cut the yellow tubing 

approximately 1” away 

from the tank valve 

fitting to relieve the 

pressure.  Remove the 

1” piece from the tank 

fitting.

IMPORTANT: 

 After 

the installation 

is complete, it is 

recommended that 

the 3/8” x 1/4” union 

connector be saved 

for future use in tank 

sanitization.

I. INSTALL 

THE DRAIN 

CONNECTION

IMPORTANT: 

 

Before starting this 

procedure, inspect the 

condition of the drain 

piping, especially in 

older homes where the 

traps and tailpieces can be deceptively thin and frail.  If they are in poor 

condition, replace prior to installing the drain connection.

IMPORTANT:  Some local plumbing codes may prohibit the use of 

saddle-type drain connections.  

Undercounter Installation:

 

The drain saddle assembly is designed to fit around a standard 

1-1/2” OD drain pipe.  For smaller (lavatory type) or larger (ABS pipe) 

drains, consult your professional installer for special drain saddles.

MOUNT

HERE

NEVER

MOUNT

HERE

GARBAGE

DISPOSAL

Fig. 4

7

Vertical Position

Horizontal Position

Nut

Screw

Drain Saddle

Elbow

IMPORTANT:

Hole should be located on

top of the pipe if drain saddle

is positioned horizontally.

Drain Saddle

Halves

Fig. 5

Fig. 3

1/4” Orange 

Tubing

Faucet Stem

Undersink

Faucet Adapter

Cold Water

Feed Tube

Collet

Backstop

“Using Push-In Fittings”

CAUTION

To Attach Tubing

Push tubing in as far as 

it will go. Tubing must 

be inserted past o-ring 

and hit backstop. Pull 

tube to ensure it is 

secured.

To Release Tubing

Push in grey collet to 

release tubing. With 

collet held, pull tubing 

straight out. 

To reduce the risk associated with property damage due to 

water leakage:

  •  Ensure all tubing and fi ttings are secure and free of leaks.

Correct

Incorrect

Cut Tubing Straight

Содержание 3MRO401

Страница 1: ...dration Hot and cold beverages Cooking and food preparation Pet hydration Aquatic aquariums Optimized For Reduction Of Select Volatile Organic Compounds VOCs System tested and certified by NSF Interna...

Страница 2: ...to small parts during the installation of this product To reduce the risk associated with ingestion of contaminants Do not use with water that is microbiologically unsafe or of unknown quality without...

Страница 3: ...system Where a booster pump is installed on a water system you must install an appropriate pressure relief valve Pres sure relief valve must be maintained and inspected every 6 months Contact a plumbi...

Страница 4: ...ing location 5 D Make the faucet mounting hole 5 E Mount the faucet 6 F Prepare the system for installation 6 G Install the feed water connection and tubing 7 H Prefill and sanitize the storage tank 7...

Страница 5: ...nothing will interfere with mounting the faucet such as reinforcing ribs support brackets or the cabinet construction If drilling a hole in your sink is required the professional installer should foll...

Страница 6: ...Gap is provided by hole 1 above faucet base 1 Familiarize yourself with all of the components shown in the air gap faucet diagram See Fig 2 2 Slide the chrome base plate and rubber washer up the thre...

Страница 7: ...y and the tank valve Disconnect the orange and yellow tube from the union connector setting the tank aside while proceeding with the rest of the installation the sanitizing solution should be kept in...

Страница 8: ...ween the sink basins for ease of access if space permits K MAKE THE TUBING CONNECTIONS With all of the components in place the tubing connections can be made When routing the tubing between the compon...

Страница 9: ...The drain line has a loop in it Air is locked in the air gap outlet There is excessive RO reject flow Solutions Check to see that the drain line is clear of any obstruction and remove the drain saddle...

Страница 10: ...ed valve Wait five 5 minutes for the filtration assembly to completely depressurize 2 Remove cover 3 Twist the existing filter 1 4 turn to the left so that the ears on the filter are able to disengage...

Страница 11: ...ly and are not designed to sanitize systems that have become highly contaminated from misuse When to Sanitize the Storage Tank Upon start up as described in the beginning of this manual After any serv...

Страница 12: ...tion Inc will replace the Product or refund your Product purchase price This warranty does not cover labor The remedy stated in this paragraph is Customer s sole remedy and 3M Purification Inc s exclu...

Отзывы: