3M 3MDW201 Скачать руководство пользователя страница 5

1.  Open faucet and turn off cold water supply to relieve pressure. 

2.  Select and mark a location under the sink that allows ac-

cess for filter change. You will be connecting to the existing 

line with 3/8” tubing and various fittings not supplied with 

this filter assembly. 

3.  Using filter head assembly as a guide, fasten filter head as-

sembly to wall with fasteners. (See Figure 1) 

  Allow 3” clearance from bottom of replacement filter for 

ease of removal.

4.  Place a basin or a towel under the cold water supply valve.  

Remove the cold side riser tubing between your cold water sup-

ply valve to your primary faucet connection. 

5.  Install faucet adapter fitting (not included, see optional kit 

3MDWIKT) to faucet stem. This should be a snug fit. Do 

not overtighten.  (See Figure 2) Ensure the black gasket is 

inserted into the faucet adapter prior to assembly.

  Determine length of 3/8” tubing (not included, see optional 

kit 3MDWIKT) required from filter head outlet to faucet 

adapter by holding tubing in place ensuring it is of appropri-

ate length. Do not kink tubing as this will impede water flow. 

If necessary, loop tubing around to avoid it being kinked.  Cut 

tubing straight with a razor knife. (See Figure 3)

6.  Insert 3/8” tubing from faucet adapter fitting into the filter 

OUTLET fitting as shown in Figure 5.

7.  Determine length of 3/8” tubing (not included, see optional kit 

3MDWIKT) required from filter head inlet to cold water supply 

valve by holding tubing in place ensuring it is of appropriate 

length. Do not kink tubing as this will impede water flow. If nec-

essary, loop tubing around to avoid it being kinked.  Cut tubing 

straight with a razor knife.  (See Figure 3)

8.  Using a ferrule, nut and tube support (not included, see op-

tional kit 3MDWIKT), slide nut and ferrule over 3/8” tubing, 

insert tube support and connect to the cold water supply 

valve.  (See Figure 4)  Insert other end into filter INLET fit-

ting as shown in Figure 5.

9.  Remove sanitary protective cap from filter. Ensure both 

o-rings are present on the filter and are seated into grooves; 

moisten o-rings with water.  DO NOT use any petroleum 

products to lubricate the o-rings.

Correct Incorrect

Figure 3

Figure 4

Figure 2

•  Allow a minimum of 3” (7.6 cm) clear space under the system to facilitate filter changes.

•  All components should be accessible and have a sufficient amount of clearance on all sides of 

the system to facilitate servicing.

Figure 1

IMPORTANT INSTALLATION INSTRUCTIONS

Note: White tube from head is a filter vent tube outlet.  DO NOT remove, kink or obstruct white tube.

3/8” Tubing

3/8” Compression Nut

3/8” Tube Ferrule

3/8” Tube Support

Cold Water

Supply Valve

The following installation instructions described are based on copper plumbing with 3/8” compression 

fittings.  Additional fittings may be required to connect to cold water supply.

Содержание 3MDW201

Страница 1: ...Installation and Operating Instructions For 3MDW201 Full Flow Drinking Water System 3M Clean Water Solutions Homeowner Please retain for operation and future maintenance instructions ...

Страница 2: ......

Страница 3: ...r from freezing remove replacement filter when temperatures are expected to drop below 40 F 4 4 C Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C Do not install on hot water supply lines The maximum operating water temperature of this filter system is 100 F 37 8 C Do not install if water pressure exceeds 125 psi 862 kPa If your water pressure exceeds 80 psi 552...

Страница 4: ...ncluded Adjustable wrench Cordless drill Phillips head screwdriver Razor knife or tube cutter Additional installation parts may be required 3MDWIKT installation kit GETTING STARTED 1 2 Installation requires some household tools and novice plumbing skills If you replace your own kitchen and bathroom faucets you can handle this ...

Страница 5: ...Determine length of 3 8 tubing not included see optional kit 3MDWIKT required from filter head inlet to cold water supply valve by holding tubing in place ensuring it is of appropriate length Do not kink tubing as this will impede water flow If nec essary loop tubing around to avoid it being kinked Cut tubing straight with a razor knife See Figure 3 8 Using a ferrule nut and tube support not inclu...

Страница 6: ...for leaks Repair any leaks as needed before continuing The system is now ready for use CAUTION To reduce the risk associated with property damage due to water leakage The disposable replacement filter must be replaced every twelve 12 months at the rated capacity or sooner if a noticeable reduction in flow rate occurs Collet Backstop Using Push In Fittings To Attach Tubing 1 Push tubing in as far a...

Страница 7: ...from abuse misuse alteration or damage not caused by 3M or failure to follow installation and use instructions No warranty is given as to the service life of any filter cartridge or membrane as it will vary with local water conditions and water consumption If the Product fails to satisfy this Limited Warranty during the warranty period 3M will replace the Prod uct or refund your Product purchase p...

Страница 8: ...3M is a trademark of 3M Company 2009 3M Company All rights reserved INSTR8029 0909 Manufactured by 3M 400 Research Parkway Meriden CT 06450 1 877 238 9119 www 3MCleanerWorld com ...

Отзывы: