SYSTEM AND PLUMBING SET-UP INSTRUCTIONS
CAUTION
To reduce the risk associated with property damage due to water leakage:
•
Installation must comply
with existing state or local plumbing codes, even if they are contrary to our instructions.
•
Do not
use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing.
• On plastic fittings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.
• Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if over tightening occurs.
IMPORTANT NOTES
•
Damage due to heat is not covered under the manufacturer’s warranty and will void the warranty.
•
The use of flexible drain lines are prohibited in some states, check with your local code officer for requirements. Distance and height affects the
performance of the drain line to discharge at the proper rate to effectively backwash the filter media. The following are guidelines for drain line size
installation. Do not bend the drain line too sharply if using flexible tubing. Secure the drain line over the discharge line to prevent splashing or blow
out during regeneration. Do not use garden hose or vinyl tubing as a drain line as this may cause a failure to regenerate properly.
Step 1
Inspect and open factory sealed box to ensure all components required for installation are present. If media was ordered, verify the amount and type of
filter media (ordered separately) is correct. (See Section 6, page 6-2.)
Step 2
Remove filtration system from shipping carton and inspect to ensure there is no damage to product from shipping. Inspect any packing for components
that have been attached for shipping before discarding. If any items intended for installation are missing at this time contact your Dealer/Installer or our
Customer Care Team at 855-3M-WATER (855-369-2837) to notify them of this situation. Provide the model number and serial number when contacting
your Dealer/Installer or our Customer Care Team.
Step 3
Follow the steps to center the distributor tube and load the filter media into the media tank for successful installation of the 3MAPPM Iron Reduction
Filtration System.
a. Remove the control valve from the media tank by rotating the valve head assembly to the left (counter-clockwise) and set aside to reassemble after
media is loaded into tank.
b. Tilt media tank to a 45 degree angle until gravel shifts to the side of the tank and dimple at bottom of media tank is visible. This will allow you to
place the distributor tube basket assembly in the dimple on the bottom of the media tank.
c. Place media tank back in upright position and ensure gravel at the bottom of the media tank is level. Place red plastic cap on the distributor tube
that is provided in the parts bag.
d. Locate the filter media that will be used in the iron reduction filter and load into the media tank. Note: fill only to the labeled line on the outside of
the media tank. Refer to Section 6 Specification and Operating Data, page 6-1, for the correct quantity for your filter system. Use a clean rag to wipe
the opening of the media tank to remove any dust or sediment before moving to the next step.
CAUTION
To reduce the risk associated skin, eye, and respiratory tract irritation from gravel and filter media during installation:
• Gravel and several types of filter media may be used in this product, depending upon the application. During installation, dust may cause irritation to skin,
eyes, and respiratory tract.
• Utilize a NIOSH-approved dust filter mask, protective gloves, and appropriate eye protection when handling and pouring gravel and filter media.
• To request an MSDS relating to this product, call 203-238-8965 or go to www.3M.com , select country, and use the search engine to search MSDS. For
emergencies, call 800-364-3577 or 651-737-6501 (24 hours).
3-4