5.0 Strength Member Termination
5.1
Slide two sealing washers down each cable. Use sealing washers with smallest inside diameter which
will slide on cable.
Note:
If necessary, sealing washers can be split and placed on the cable.
5.2
Locate cables in appropriate entrance ports, as shown.
5.3
Strength Member Termination for Non-Shielded Cable
a.
Cut strength member 1.75" (44.5 mm) from cable
sheath end.
1.75" (44.5 mm)
b. Install strength members into 3M™ 2172 Strength Member Clamp by loosening screw and placing
strength member under screw assembly. Insure strength member is flush with end of clamp prior to
tightening the screw. Install rubber boot onto clamp.
Note:
To insure proper fit, remove coating on strength member.