Offers possibility to communicate with both the
Primary and Secondary Zeus™ Servers using
different interfaces. This feature makes the device
more robust and dependable as an alarm panel
communicator. You can configure different
interfaces as per your preference for both the
Primary and Secondary Zeus™ Servers.
Capable of sending user friendly customized
messages related to Alarm Panel Events and
Pegasus™ Occurrences to the configured
phone numbers. Maximum four phone numbers
can be configured per Alarm Panel Event or
Pegasus™ Occurrence.
Built-in GSM Jammer. GSM Jammer when
enabled allows you to identify active jamming of
the GSM/GPRS network. This feature helps to
prevent intruders that use GSM Jammers to
interfere with the normal network operation of the
device.
Offers FOTA capability, firmware updates are
issued directly over-the–air from the GSM
service provider to the GSM modem.
Previously, firmware updates to the GSM
modem required the help of specific service
center. Another method of receiving updates has
been by connecting the modem via a cable to a
PC. Both of these methods were considered
inconvenient by consumers and also relied on
consumers actively seeking out updates.
Therefore, 3i-Corporation® have now adopted
FOTA technology to update the GSM modem.
Allows device configuration through Ethernet.
Содержание Pegasus NX
Страница 32: ...28 ...
Страница 36: ...32 ...
Страница 37: ...33 Single Mode Normally Close N C Contacts without End of Line EOL Resistor ...
Страница 38: ...34 Single Mode Normally Close N C Contacts with End of Line EOL Resistor ...
Страница 39: ...35 Single Mode Normally Open N O Contacts with End of Line EOL Resistor ...
Страница 40: ...36 Single Mode Normally Close N C Contacts without End of Line EOLResistor with Tamper Recognition ...
Страница 41: ...37 Single Mode Normally Close N C Contact With End of Line EOL Resistor with Tamper Wire Fault Recognition ...
Страница 42: ...38 Double Mode Normally Close N C Contacts without End of Line EOL Resistor ...
Страница 43: ...39 Double Mode Normally Close N C Contacts without End of Line EOL Resistor with Tamper Recognition ...
Страница 44: ...40 Double Mode Normally Close N C Contacts with End Of Line EOL Resistor with Tamper Wire Fault Recognition ...
Страница 45: ...41 Double Mode Parallel Connection ...