page
24
of
24
3DGence INDUSTRY F340 - maintenance activities | version 04.2019
For a correctly tensioned Timing Belt on the X2 axis, the measured value should be between 93 and 100
Hz.
9.
Measuring the timing belt tension on the Y axis (Fig. 38):
•
Place the phone with the microphone facing the toothed belt side at the third black mounting hole of the
linear guide counting from the fan side of the on the rear of the printer (Fig. 45).
Fig. 45 Measurement location of the timing belt tension on the Y axis
•
Select the start button in the app.
•
Make the timing belt vibrate by vigorously jerking it like a guitar string until the measuring fields in the
app light up green.
•
Check the tension value in the app.
For a correctly tensioned Timing Belt on the Y axis, the measured value should be between 50 and 55 Hz.
If the measured tension values of the X1, X2 or Y axes are not within the specified ranges, please contact the
3DGence Technical Support for assistance.
13. BOWDEN CABLE REPLACEMENT
Recommended frequency:
in the case of damage.
In the case of damage, please contact the 3DGence Technical Support for assistance.
14. HEATBED REPLACEMENT
Recommended frequency:
in the case of damage.
In case of damage, please contact 3DGence Technical Support to purchase a new heatbed and obtain assistance.
3DGence Sp. z o.o.
Branch of Przyszowice, ul. Graniczna 66, 44-178 Przyszowice
+48 32 438 98 64
[email protected]