ZPrinter
®
150 / ZPrinter 250 User Manual
ZPrinter 150 / ZPrinter 250 Overview
2
All Rights Reserved
11/1/12
1.2 Specifications
Specifications apply to both the ZPrinter 150 and ZPrinter 250, unless noted otherwise. Type 1 refers to
older hardware versions of the ZPrinter 150/250; Type 3 refers to the latest hardware versions.
Printer Dimensions and Type
•
With top cover closed: 29” wide x 31” deep x 55”
high. (74 cm wide x 79 cm deep x 140 cm high)
•
With top cover open: 29” wide x 31” deep x 72” high.
(74 cm wide x 79 cm deep x 183 cm high)
•
Floor standing model on four casters. The front two
casters are lockable.
•
Integrated vacuum system.
Printer Weight
365 lbs. (166 kg)
Network Connectivity
TCP/IP 100/10 Base T
Operating Environment
Ambient Temperatures
Ambient Relative Humidity
•
Maximum Temp. Range: 50-85° F (10 - 29.4° C)
•
Recommended Temp. Range: 55-80° F
(12.7 - 26.6° C)
•
Maximum RH Range: 15 - 70%, non-condensing
•
Recommended RH Range: 20 - 60%,
non-condensing
(May experience sub-optimal printing performance at
environmental extremes.)
Build Volume
7.3" x 9.3" x 5" (185 x 236 x 132 mm)
340 cubic inches build capacity
Build Speed
2-4 layers per minute
Layer Thickness
.004” (.102 mm)
Resolution
300 x 450 dpi print resolution
Minimum feature size .016” (.41 mm)
Color Reproduction
Will reproduce 64 unique colors (ZPrinter 250 only)
Noise Levels
During Printing = 57dB
Emptying Overflow = 66dB
Vacuuming - Cover Open = 86dB
CSA, CE Approval
Meets CE certification standards and UL standards.
Power Requirements
Type 1:
100V~, 5.5 A, 50 Hz,
115V~, 5.5 A, 60 Hz
230V~, 2.75A, 50 Hz
Type 3:
100 - 120V~, 6.0 A, 50 - 60 Hz
230V~, 2.75 A, 50 - 60 Hz
Fuse: 6.3A 250V Time Delay