   OVERVIEW

Technology

Water Jet Blasting with recirculating water compressed air with integrated supply.

Weight

170 kg / 374.7 lbs

Size with closed protective hatch 75 x 66 x 170 cm / 29.5 x 25.9 x 66.9 inch
Size with open protective hatch

75 x 66 x 225 cm / 29.5 x 25.9 x 88.5 inch

Minimum Dimensions for

Convenient Access

Density is designed to be placed on a flat horizontal surface. Recommended installation

area is 100 cm x 100 cm / 39.3 x 39.3 inch

Operating Temperature

15-25 °C / 59-77 °F

Power Requirements

• 250 V Earth Connected with RDC
• ~ 10 A
• 50 Hz
• Peak 1800 W
• Nominal 800 W
• The Density should be connected to a separate fuse from the Gravity.

US Power Requirements

• 125 V
• 15 A
• 60 Hz
• Nominal 800 W
• The Density should be connected to a separate fuse from the Gravity.

Sound Emission

Does not exceed 85 dB(A)

Machine Control

Buttons at the front. Handles in the blasting chamber.

Ventilation

Well ventilated with free-flowing air.

3D Systems, Inc.

4

p/n 74-D002, Rev. A

Содержание wematter Density

Страница 1: ...User Guide Release Date 7 19 2023 Original Instructions...

Страница 2: ...TUP 6 4 1 Arranging the Workspace 6 4 2 Water 6 4 3 Filter 7 5 MACHINE USE 8 5 1 Loading 3D Prints 8 5 2 Cleaning 3D Prints 8 5 3 Removing 3D Prints 9 5 4 Changing the Filter 9 5 5 Refilling Water 10...

Страница 3: ...expiration of the date of issuance 3D Systems may institute a periodic charge or fee payable by the Licensed User in return for ongoing receipt of improvements It is the responsibility of the Licensed...

Страница 4: ...tion CAUTION Indicates the possibility of loss of data or damage to equipment WARNING INDICATES THE POSSIBILITY OF INJURY OR DEATH TO PERSONNEL Electrical Shock High voltage electricity is accessible...

Страница 5: ...ymeric powders The final performance characteristics of the machine may vary according to your compliance with the instructions for use design guidelines application operating conditions fluids combin...

Страница 6: ...ce Recommended installation area is 100 cm x 100 cm 39 3 x 39 3 inch Operating Temperature 15 25 C 59 77 F Power Requirements 250 V Earth Connected with RDC 10 A 50 Hz Peak 1800 W Nominal 800 W The De...

Страница 7: ...d in the Essential system version does not come with the Compressed air with an integrated supply feature The Essential version therefore has two instead of three buttons on the front machine control...

Страница 8: ...utlet 4 2 Water The machine shall be filled with 20 2 liters of tap water before turning the system on This is done by pouring water into the blasting chamber Figure 1 Pour 20 liters of water straight...

Страница 9: ...he grid in the blasting chamber and make sure there is a filter in place The grid is opened by pulling the handle Figure 2 There must be a filter in place before the machine is used 3D Systems Inc 7 p...

Страница 10: ...the chamber to turn on and off the water jet 4 CAUTION Only shoot water against the back of the chamber as the high pressure water may damage the lid seal and cause water leakage Keep the 3D printed p...

Страница 11: ...er before removing the filter If not there will be water on the floor You can visually check if there is still water in the filter before removing it 1 Open the grid in the blasting chamber by lifting...

Страница 12: ...e the lid before shooting water in the chamber There are approximately 20 liters of water inside the Density so you will have to empty the bucket a few times during the process The system is empty whe...

Страница 13: ...em by shooting with the air gun in the blasting chamber 2 When the pressure has been removed from the system go to the right side of the Density At the bottom of the right side you find two valves 3 P...

Страница 14: ...ion Job parameters if set differently from the defaults Build file if not restricted by company policy Log files with timestamp Relevant pictures and or videos The steps you took that produced the err...

Страница 15: ...eserved Specifications subject to change without notice 3D Systems and the 3D Systems logo are registered trademarks of 3D Systems Inc 3D Systems Inc 333 Three D Systems Circle Rock Hill SC 29730 www...

Страница 16: ...3dsystems com Register Statement 2023 by 3D Systems Inc All rights reserved Specifications subject to change without notice 3D Systems and the 3D Systems logo are registered trademarks of 3D Systems I...

Отзывы: