  COMPRESSED AIR REQUIREMENTS

A customer supplied compressed air system must be in place 

before

 the ProX

®

 DMP100 is installed.

When installing the compressed air supply line:

• 

Route compressed air supply line through the ceiling.

• 

Locate the drop over the control panel.

• 

Keep the compressed air line as short as possible to ensure proper pressure.

The connection for the compressed air supply is located on the bottom right of the printer.

Compressed Air

ProX

®

 DMP100

Connection Type

Quick coupler plug, internal diameter 6mm

Flow Rate

10 L/min (0.35 cubic feet per minute)

Supply Pressure

Minimum 6 bar (87 psi)  -  Maximum 8 bar (116 psi)

Quality

Class 4,4,4 according to ISO 8573-1:2010

9

  WORKSTATION AND SOFTWARE REQUIREMENTS

Supplied by

: Computer : Customer or 3D Systems - Software : 3D Systems

Installed by

: Customer or 3D Systems

Before a part can be built on the printer, the manufacturing file must be loaded into the printer.
The manufacturing file is generated by 

3DXpert

 or 

ProX DMP Dental

 (only for dental application) standalone softwares. By 

using the industry-standard .stl file format, the manufacturing file includes a series of sliced cross-sections of the part and all 

the manufacturing parameters.

The manufacturing file can be uploaded by:

1 .  Ethernet network connection : the printer provides an integrated 10/100-megabit-per-second (Mbps) Ethernet network connection . 

This connection supports both the 10base-T and 100base-TX Ethernet standards . The connectors (RJ45 sockets located on the 

back panel of the supply cabinet and in front of the main cabinet) are designed for attaching a shielded twisted pair Ethernet cable 

(supplied with the printer) .

2 . 

USB connection : the printer provides an integrated USB socket. The manufacturing file can be uploaded with a USB key (not 

supplied) .

The manufacturing file is then selected from the printer.

Prior to installing the software, ensure that workstation meets the following minimum specifications (next page). The 

specifications described represent 3D Systems tested minimum “baseline” configuration for using the software. Although 

the software will run on less powerful computers, meeting the minimum recommended configuration will ensure acceptable 

performance.

Содержание ProX DMP 100

Страница 1: ...D Production Printer Facility Requirements Guide Original Instructions Please refer back to http infocenter 3dsystems com product library prox 100 facility guide for the most up to date facility requi...

Страница 2: ...age 7 5 ATMOSPHERE REQUIREMENTS 8 Room Ventilation 8 Room Air Source 8 Room Air Exhaust 8 6 ELECTRICAL REQUIREMENTS 9 7 GAS REQUIREMENTS 9 8 COMPRESSED AIR REQUIREMENTS 10 9 WORKSTATION AND SOFTWARE R...

Страница 3: ...3D SYSTEMS INC 17 CONTACT INFORMATION 16 18 FACILITY REQUIREMENTS POSTER 17...

Страница 4: ...s must only be done by your 3D Systems certified Customer Support Engineer CSE during installation Attempts to install equipment or auxiliary equipment by non 3D Systems certified personnel could void...

Страница 5: ...kg 2932 15 lbs Dimensions Length x Width x Height 1640 x 1010 x 2350 mm 64 57 x 39 76 x 92 52 in Process filter Weight 150 kg 330 69 lbs Dimensions Length x Width x Height 740 x 1010 x 1310 mm 29 13 x...

Страница 6: ...e 5 10 L min 0 17 0 35 cubic feet per minute Purge flowrate 30 L min 1 06 cubic feet per minute Quality purity 99 99 for Nitrogen purity grade 4 8 minimum for Argon Connection on the bottom right Quic...

Страница 7: ...ter replacement Physical Dimensions Dimensions H x W x D 1431 x 809 x 879 mm 56 34 x 31 85 x 34 61 in Weight 94 kg 207 23 lbs Electrical N A Mechanical Connection The filter is connected to the main c...

Страница 8: ...RUWAC NA35 serie explosion proof vacuum is recommended Oxygen Monitor Supplied by Customer or 3D Systems Installed by 3D Systems For safety when working with argon you must install a room area oxygen...

Страница 9: ...esiccant bags The storage period is limited to 6 months from the date of packing The printer must be stored in their original packaging in a stable position protected from impact and in a dry location...

Страница 10: ...h as but not limited to oxidizers and fuels Store in a fireproof cabinet Make certain you have small containers for small quantities of powder Do not store small quantities of powder in large vessels...

Страница 11: ...ERIC VARIABLES REQUIREMENTS Room temperature Heating and air conditioning installed A C not blowing directly onto the main cabinet Temperature Operating range 15 to 30 C 59 to 86 F Storage range 5 to...

Страница 12: ...et The connection of the gas supply is located on the bottom right of the printer Gas ProX DMP100 Connection Type Quick coupler plug internal diameter 6mm Flow Rate Manufacturing 5 10 L min 0 17 0 35...

Страница 13: ...or dental application standalone softwares By using the industry standard stl file format the manufacturing file includes a series of sliced cross sections of the part and all the manufacturing parame...

Страница 14: ...fessional Ultimate Edition Windows XP 64 bit is not supported All 32 bit operating systems are not supported CPU Quad cord 64 bit processor Intel core i7 6th generation and up RAM 8 GB 16 GB or more L...

Страница 15: ...Copper Beryllium CuBe2 alloys These are the only tools that are safe to use in EX zones where hazardous flammable or combustible materials are present The following items are required All electric too...

Страница 16: ...tion of an inert gas system for fire suppression Although a class D is required for metal fires do not neglect to have a class ABC portable on hand as well for non metal fires that class D is not effe...

Страница 17: ...tall the equipment HOW TO SUBMIT YOUR COMPLETED FACILITIES CHECKLIST Submit your completed Facility Requirements Checklist by fax mail or email to one of the 3D Systems Customer Support sites below Th...

Страница 18: ...Requirements completed Electrical Requirements completed Measured 230 VAC facility power ________ VAC ________ Hz Gas Requirements completed Compressed Air Requirements completed Computer and Network...

Страница 19: ...ems com www 3dsystems com NYSE DDD Customer Support Hotline US and Canada 888 598 1438 International 1 803 326 3930 UK and EMEA 44 1442 279883 Europe 33 4 73 33 45 85 Sales and Service Phone Numbers F...

Страница 20: ...with your local state and federal regulations Always refer to the pipe color coding standards of your local state and federal regulations Room oxygen monitor recommended customer supplied installed s...

Страница 21: ...3D SYSTEMS INC 3D Systems Inc 333 Three D Systems Circle Rock Hill SC 29730 USA www 3dsystems com 2017 3D Systems Inc All rights reserved PN 80 D47 Rev B...

Отзывы: