MDM Heater Power Switch:
In the On position, the MDM will regulate material temperature. In the Off position,
temperature regulation doesn’t occur. This functions in both Standby and Print modes.
Container Release Button:
Press this button to release the material container when removing it from the material bin.
Fill Pump:
The peristaltic fill pump controls the material height in the MDM by moving material to or from the leveling
reservoir (see letter “H”). For replacing the tubing on the peristaltic pump, refer to the section
the Parastaltic Pump” on page 68
Leveling Reservoir:
This reservoir is used to store material for transferring into or out of the print area to maintain the
precise material height during printing.
Applicator Rest:
This rest area is used to stow the removable applicator when changing MDMs.
I
J
K
L
M