2. 3 DIP Switch Setting
Before start up the camera, set the protocol and camera address and termination set with dip-switches
and click-switches as shown in the below diagram.
1.Set the camera address (ID)
2. Protocol, Baudrate, Camera setting
3.Set the termination On/Off
Address switch
Open the top cover of the product to set camera address.
* ID setting is 1~255 available
S1
S3
S4
S1 : 1-digit number of address
S3 : 10-digit number of address
S4 : 100-digit number of address
Ex) S4 = 1
S3 = 2
S1 = 8
The ID number is 128.
1
2
3
4
5
6
7
8
9 10 11 12
ON
DIP
1
2
3
OFF OFF OFF
OFF OFF ON
OFF
ON OFF
OFF
ON
ON
ON
OFF OFF
ON
OFF ON
ON
ON OFF
ON
ON
ON
PELCO-D
PELCO-P
WTX
EZP
NC
NC
NC
NC
PROTOCOL
4
5
6
OFF OFF OFF
OFF OFF ON
OFF
ON OFF
OFF
ON
ON
ON
OFF OFF
ON
OFF ON
ON
ON OFF
ON
ON
ON
2400
4800
9600
19200
38400
57600
115200
NC
BAUDRATE
7
OFF
ON
RS-422
RS-485
RSMODE
9
OFF
ON
OFF
ON
RS LOOP
11
OFF
ON
IP OFF
IP ON
IP SELECT
8
OFF
ON
NTSC
PAL
NTSC/PAL
10
OFF
ON
NC
NC
NC
12
OFF
ON
OFF
PROGRAM MODE
BOOTO
The device which is connected at the end of the line must have the
cable communication terminated. Without proper termination,
there is potential for control signal errors.
The product have the cable communication terminated by setting
the appropriate dip switch.
9
ON : Terminated
OFF : Not terminated
Содержание TPD-HD330NRW
Страница 39: ...39 6 DIMENSION 6 1 DIMENSION 157 9 Ø231 R82 5 160 6 206 18 384 6 1 1 2inch PF TAP Ø231 ...
Страница 40: ...40 446 452 Ø231 175 145 125 100 4 Ø8 5 ...
Страница 41: ...41 366 6 529 90 120 120 150 Ø 231 157 9 Ø231 R82 5 93 55 160 6 206 ...
Страница 42: ...42 7 CONFIGURATION 7 1 Connecting to Keyboard with DVR ...
Страница 43: ...P N 388067625 PRINTED IN KOREA Distributed by ...