2-32
The Telnet user names added to the RADIUS server must be in the format of
userid
@
isp-name
if you
have configured the switch to include domain names in the user names to be sent to the RADIUS server
in the RADIUS scheme.
Network diagram
Figure 2-3
Remote RADIUS authentication of Telnet users
Configuration procedure
# Enter system view.
<Sysname> system-view
# Adopt AAA authentication for Telnet users.
[Sysname] user-interface vty 0 4
[Sysname-ui-vty0-4] authentication-mode scheme
[Sysname-ui-vty0-4] quit
# Configure an ISP domain.
[Sysname] domain cams
[Sysname-isp-cams] access-limit enable 10
[Sysname-isp-cams] quit
# Configure a RADIUS scheme.
[Sysname] radius scheme cams
[Sysname-radius-cams] accounting optional
[Sysname-radius-cams] primary authentication 10.110.91.164 1812
[Sysname-radius-cams] key authentication aabbcc
[Sysname-radius-cams] server-type Extended
[Sysname-radius-cams] user-name-format with-domain
[Sysname-radius-cams] quit
# Associate the ISP domain with the RADIUS scheme.
[Sysname] domain cams
[Sysname-isp-cams] scheme radius-scheme cams
A Telnet user logging into the switch by a name in the format of
userid
@cams belongs to the cams
domain and will be authenticated according to the configuration of the cams domain.
Local Authentication of FTP/Telnet Users
Содержание Switch 4210 52-Port
Страница 253: ...ii Configuring Dropping Unknown Multicast Packets 3 2 Displaying Common Multicast Configuration 3 3 ...
Страница 434: ...3 13 Switch Ethernet1 0 2 ip source static binding ip address 1 1 1 1 mac address 0001 0001 0001 ...
Страница 675: ...ii Configuring a Scheduled Task 5 1 Scheduled Task Configuration Example 5 2 ...
Страница 695: ...2 2 ...
Страница 867: ...i Table of Contents Appendix A Acronyms A 1 ...