Basic Frame Relay Configuration Using the Command Line Interface
207
3
Specify additional network parameters for the user.
a
If you are configuring an unnumbered interface, use the following
command:
set network user <username> remote_ip_address
<xxx.xxx.xxx.xxx/x>
The remote_ip_address for an unnumbered link may be the IP address
of the remote router Ethernet port, depending on the configuration of
the remote router.
b
If you are configuring a numbered interface, use the following
command:
set network user <username> remote_ip_address
<xxx.xxx.xxx.xxx/x>
set dial_out user <username> local_ip_address
<xxx.xxx.xxx.xxx>
The remote_ip_address for a numbered link is the IP address of the
remote router WAN port. The local_ip_address is the IP address of the
local router WAN port.
4
Set the user routing options as follows. For a command description see
Table 54.
set network user <username> ip_routing [both | send | listen
| none] rip [ripv1 | ripv2]
5
For IPX, specify the network address, WAN status, routing options, and
spoofing status.
set network user <username> ipx_address <ipx net address>
ipx_wan [enable | disable] ipx_routing [all | listen | none |
respond | send] spoofing [enable | disable]
6
For IPX, specify an internal IPX system number to support IPX_WAN.
set ipx system number <number> name <system name>
Table 54
IP Routing Levels
Command
RAS 1500
Listen
Listens to RIP updates from the user and updates the local routing
table
Send
Sends RIP updates to the user
Both
Listens to and send RIP updates
None
Does not listen to nor send RIP updates
Содержание REMOTE ACCESS SYSTEM 1500
Страница 14: ......
Страница 40: ......
Страница 58: ......
Страница 120: ......
Страница 130: ......
Страница 158: ......
Страница 178: ......
Страница 202: ......
Страница 266: ......
Страница 286: ......
Страница 292: ......
Страница 297: ...INDEX 295 V 90 151 W Windows 95 Dial Up Networking 89 World Wide Web WWW 285 X X 75 152 ...
Страница 298: ...296 INDEX ...