3
The LED Indicators on the front panel of the OfficeConnect
Gateway Voice Expansion Unit provide the following
information:
Rebooting the Office Connect Gateway Voice Expansion Unit:
To reboot a unit that is powered up, press and hold the Reset
button for at least two seconds.
Reset Button
The Reset button is located on the rear panel of the
OfficeConnect Gateway Voice Expansion Unit. Please refer to the
installation diagram to see the location of this button.
Rebooting
the Unit
Front Panel
Indicators
Alert
Off
Off indicates the unit has passed the Power On Self-Test and is working properly.
Amber
Lit during Boot up of the unit. Remains lit until synchronization with the base unit occurs.
Amber (blinking) Occurs in the following situations:
1) A version incompatibility is detected between it and the OfficeConnect Gateway base unit.
2) A software upgrade of the Voice Expansion Unit is being performed by the base unit.
Refer to the Troubleshooting section in the OfficeConnect Gateway User’s Guide.
Red
Indicates a diagnostic failure in the unit. Refer to the Troubleshooting section in the
OfficeConnect Gateway User’s Guide.
Power
Off
Power not being supplied to the unit.
Green
Remains lit as long as power is supplied to the unit.
Expansion LED
Off
Base unit not detected or there is no synchronization with the base unit.
Green (blinking)
Base unit detected. Synchronizing and waiting for the base unit to assume master control.
Green
Base unit synchronized and in control of OfficeConnect Gateway Voice Expansion Unit.
Phone Status
1-8
Off
Onhook. The phone port is not being used.
Green
Offhook. The phone port is being used.