background image

 

1-78 

Panel and LEDs 

Figure 1-52 

LSQ1GP24TSC0 panel 

 

 
Each Ethernet port has one green LED. Table 1-152 describes the LEDs on the LSQ1GP24TSC0 
panel. 

Table 1-152 

Description of the LED of each Ethernet port 

Status 

Meaning 

OFF 

No link is present. 

ON 

A link is present. 

Blinking 

Data is being transmitted or received. 

 

LSQ1GP24TSD0 

Introduction 

The LSQ1GP24TSD0 provides sixteen 1000Base-X-SFP/100Base-FX-SFP ports and eight Combo 
ports. 

Table 1-153 

Technical specifications of the LSQ1GP24TSD0 

Item 

Specifications 

CPU 

MIPS64, 1 GHz 

Boot ROM  

4 MB 

DDR SDRAM 

1 GB 

Dimensions (H × W × D) 

40 × 377 × 355 mm (1.57 × 14.84 × 13.98 in.) 

Power consumption 

47 W to 75 W 

Connector type 

z

 

LC 

z

 

RJ-45 

Number of ports 

z

 

16 SFP ports 

z

 

8 Combo ports 

1000Base-X-SFP/100Base-FX-SFP port: 1000/100 Mbps 

Transmission speed and 

type 

10/100/1000Base-T port: 

z

 

10/100/1000 Mbps, half/full duplex 

z

 

MDI/MDI-X auto-sensing 

Pluggable module type 

z

 

Gigabit SFP modules 

z

 

100 Mbps SFP modules 

For details, refer to “Appendix A  List of Pluggable Optical Modules.”

 
Table 1-154 shows the pairings of the SFP and the 10/100/1000Base-T ports for the Combo ports. 

Содержание H3C S7503E-S CHASSIS

Страница 1: ...H3C S7500E Series Ethernet Switches Installation Manual Hangzhou H3C Technologies Co Ltd http www h3c com Manual Version T2 080406 20090526 C 1 06 ...

Страница 2: ... V2 G Vn G PSPT XGbus N Bus TiGem InnoVision and HUASAN are trademarks of Hangzhou H3C Technologies Co Ltd All other trademarks that may be mentioned in this manual are the property of their respective owners Notice The information in this document is subject to change without notice Every effort has been made in the preparation of this document to ensure accuracy of the contents but all statement...

Страница 3: ...he H3C S7500E Series Ethernet Switches 7 Troubleshooting Introduces how to troubleshoot the configuration system power modules fans and LPUs of the H3C S7500E Series Ethernet Switches Appendix A List of Pluggable Optical Modules Introduces pluggable optical modules for different types of ports and their related parameters Appendix B AC Power Cables Used in Different Countries or Regions Introduces...

Страница 4: ...parated by forward slashes For example File Create Folder Symbols Convention Description Means reader be extremely careful Improper operation may cause bodily injury Means reader be careful Improper operation may cause data loss or damage to equipment Means a complementary description Related Documentation In addition to this manual each H3C S7500E Series Ethernet Switches documentation set includ...

Страница 5: ...al Documents Provides several categories of product documentation such as installation configuration and maintenance Technical Support Document Software Download Provides the documentation released with the software version Documentation Feedback You can e mail your comments about product documentation to info h3c com We appreciate your comments Environmental Protection This product has been desig...

Страница 6: ...SRPU LSQ1SRPA0 1 37 Salience VI SRPU LSQ1SRPB0 1 40 Salience VI Turbo SRPU LSQ1SRP1CB0 1 43 Salience VI Lite SRPU LSQ1MPUB0 1 46 Salience VI Plus SRPU LSQ1SRPD0 1 49 Salience VI GE SRPU LSQ1SRP12GB0 1 52 LPUs 1 56 LSQ1FP48SA0 1 56 LSQ1FV48SA0 1 57 LSQ1GP12EA0 1 58 LSQ1GP12SC0 1 58 LSQ1GP24SC0 1 59 LSQ1GP48SC0 1 60 LSQ1GP48SD0 1 61 LSQ1GP48EB0 1 62 LSQ1GT24SC0 1 63 LSQ1GV24PSC0 1 64 LSQ1GV48SA0 1 6...

Страница 7: ...0 1 84 LSQ1PT8PSC0 1 85 LSQ1PT16PSC0 1 86 LSQ2FP48SA0 1 87 LSQ2FT48SA0 1 88 Ordering Information for the S7500E Series 1 89 Purchasing a Switch 1 89 Purchasing SRPUs 1 90 Purchasing LPUs 1 91 Purchasing Optical Modules 1 92 Purchasing Air Filters 1 92 Purchasing Fan Trays 1 92 Purchasing PoE Modules 1 92 ...

Страница 8: ...odels as described in Table 1 1 Table 1 1 Dimensions of the S7500E series Model Slot direction Number of slots Number of SRPU slots S7502E Horizontal 4 2 half sized slots S7503E S Horizontal 3 1 S7503E Horizontal 5 2 S7506E S Horizontal 8 2 S7506E Horizontal 8 2 S7510E Horizontal 12 2 S7506E V Vertical 8 2 Physical Description of the S7500E Series Chassis and Slots The integrated chassis of the S7...

Страница 9: ...net switch S7502E Figure 1 1 shows the front panel of the S7502E Figure 1 1 Front panel of the S7502E 1 Power modules 2 SRPUs in slot 0 and slot 1 3 Fan tray 4 LPUs in slot 2 and slot 3 5 Jack for ESD preventive wrist strap All modules of the S7502E are hot swappable z The S7502E has four horizontal slots SRPUs are inserted into the upper two slots See callout 2 in Figure 1 1 SRPUs are required an...

Страница 10: ...orts on the rear panel of the chassis z The S7500E series except the S7506E S are Power over Ethernet PoE capable that is they can supply power to devices such as IP phones wireless access points and network cameras connected to their Ethernet ports through twisted pair cables z For the S7502E and S7503E S the external PoE power supply is connected to the PoE power supply input terminals on the re...

Страница 11: ...ght side of the chassis See callout 3 in Figure 1 3 z The two power modules which sit in the upper part of the chassis provide 1 1 redundancy backup and support dual power supply inputs See callout 1 in Figure 1 3 You can select either AC power supply or DC power supply Figure 1 4 shows the rear panel of the S7503E S Figure 1 4 Rear panel of the S7503E S 1 COM port for monitoring PoE RS485 2 COM p...

Страница 12: ...per two slots see callout 5 in Figure 1 5 SRPUs are required and support active standby switchover Different LPUs are inserted into the other three slots see callout 4 in Figure 1 5 z The fan tray is installed on the right side of the chassis see callout 1 in Figure 1 5 z The two power modules which sit in the lower part of the chassis see callout 3 in Figure 1 5 provide 1 1 redundancy backup and ...

Страница 13: ... in Figure 1 6 SRPUs are required and support active standby switchover Different LPUs are inserted into the other six slots see callout 4 in Figure 1 6 z The fan tray is installed on the right side of the chassis see callout 1 Figure 1 6 z The two power modules which sit in the lower part of the chassis see callout 3 in Figure 1 6 provide 1 1 redundancy backup and support dual power supply inputs...

Страница 14: ...t 5 in Figure 1 7 SRPUs are required and support active standby switchover Different LPUs are inserted into the other six slots see callout 4 in Figure 1 7 z The fan tray is installed on the right side of the chassis see callout 1 Figure 1 7 z The two power modules which sit in the lower part of the chassis see callout 3 in Figure 1 7 provide 1 1 redundancy backup and support dual power supply inp...

Страница 15: ...llout 5 in Figure 1 8 SRPUs are required and support active standby switchover Different LPUs are inserted in the other ten slots see callout 4 in Figure 1 8 z The fan tray is installed on the right side of the chassis see callout 1 in Figure 1 8 z The two power modules which sit in the lower part of the chassis see callout 3 in Figure 1 8 provide 1 1 redundancy backup and support dual power suppl...

Страница 16: ...eft two slots see callout 5 in Figure 1 9 SRPUs are required and support active standby switchover Different LPUs are inserted in the other six slots see callout 2 in Figure 1 9 z The fan tray is installed above the SRPUs and LPUs see callout 1 in Figure 1 9 and the air flows up from the bottom z The two power modules which sit in the lower part of the chassis see callout 4 in Figure 1 9 provide 1...

Страница 17: ... modules of the S7500E series Model Height Power input mode Support PoE power PSR320 A 1 U AC No PSR320 D 1 U DC No PSR650 A 1 U AC No PSR650 D 1 U DC No PSR1400 A 3 U AC No PSR1400 D 3 U DC Yes PSR2800 ACV 3 U AC Yes PSR6000 ACV 3 U AC Yes Table 1 4 Features of power modules Feature Description Protection functions Support input under voltage protection output over voltage protection short circui...

Страница 18: ...er modules and power module adapters refer to section 5 2 Removing and Installing a Power Module Table 1 5 Compatibility matrix between power modules and switch chassis Chassis right Power module below S7502E S7503E S S7503E S7506E S S7506E S7506E V S7510E PSR320 A Y1 Y1 N N N N N PSR320 D Y1 Y1 N N N N N PSR650 A Y1 Y1 Y2 Y2 Y2 Y2 N PSR650 D Y1 Y1 Y2 Y2 Y2 Y2 N PSR1400 A N N Y1 Y1 Y1 Y1 Y1 PSR140...

Страница 19: ...ower module Item Specifications Rated voltage range 100 VAC to 240 VAC 50 Hz or 60 Hz Maximum output power 300 W Dimensions H W D 40 140 350 mm 1 57 5 51 13 78 in The PSR320 A uses a 10 A AC power cable PSR320 D Figure 1 11 PSR320 D power module 1 Grounding screws 2 RTN terminal of DC input 3 Negative terminal of DC input 48 V to 60 V 4 Power switch 5 Power LED 6 Power module handle 7 Captive scre...

Страница 20: ... Power switch 4 Power LED 5 Power module handle 6 Captive screws As shown in the figure above the power switch is the power LED If the power LED is green the power supply operates normally If the LED is red the power supply is abnormal Table 1 8 Technical specifications of the PSR650 A power module Item Specifications Rated voltage range 100 VAC to 240 VAC 50 Hz or 60 Hz Maximum output power 650 W...

Страница 21: ... supply is abnormal Table 1 9 Technical specifications of the PSR650 D power module Item Specifications Rated voltage range 48 VDC to 60 VDC Maximum output power 650 W Dimensions H W D 40 140 350 mm 1 57 5 51 13 78 in PSR1400 A Figure 1 14 PSR1400 A power module 2 6 4 5 3 1 1 Captive screws 2 Power switch 3 Power LEDs 4 AC power socket 5 Power cable retainer 6 Power module handle As shown in the f...

Страница 22: ...PSR1400 D power module 8 6 4 5 3 7 2 1 1 Captive screws 2 COM port for monitoring PoE 3 Power LEDs 4 Negative terminal of DC input 48 V to 60 V 5 RTN terminal of DC input 6 Power module handle 7 System power switch 8 PoE power switch The PSR1400 D power module provides system power and PoE power The switch marked SYSTEM is used to control the system power and the other marked PoE is used to contro...

Страница 23: ...D Table 1 11 Technical specifications of the PSR1400 D DC power module Item Specifications Rated voltage range 48 VDC to 60 VDC Maximum system output power 1400 W Maximum PoE output power 6720 W 48 V Dimensions H W D 128 196 380 mm 5 04 7 72 14 96 in PSR2800 ACV Figure 1 16 PSR2800 ACV power module 1 2 3 6 7 4 5 8 9 1 Captive screws 2 System power socket 3 Power cable retainer 4 System power switc...

Страница 24: ... descriptions of these LEDs refer to section 7 2 5 Troubleshooting PSR2800 ACV Table 1 12 Technical specifications of the PSR2800 ACV power module Item Specifications Rated voltage range 100 VAC to 240 VAC 50 Hz or 60 Hz 1150 W 110 V Maximum system output power 1400 W 220 V 1150 W 110 V Maximum PoE output power 1400 W 220 V Dimensions H W D 128 196 380 mm 5 04 7 72 14 96 in PSR6000 ACV Figure 1 17...

Страница 25: ...C or 220 VAC but not be intermixed z Keep the PoE switch in the off position unless the device is equipped with appropriate PoE capable cards and needs to offer PoE supply On the right of the panel are the system power input LED SYS IN system power output LED SYS OUT system power fan LED SYS FAN PoE input LEDs PoE IN1 PoE IN2 and PoE IN3 PoE output LED PoE OUT and PoE power fan LED PoE FAN For the...

Страница 26: ...can first insert the PWR SPA power module adapters into the switch and then insert 1U power modules into the power module adapters By doing so you can use the 1U power modules to power the switch A PWR SPA power module adapter has the same physical dimensions with a 3U power module Fan Tray The S7502E S7503E S S7503E S7506E S S7506E and S7510E switches provide chassis for horizontal cards The fan ...

Страница 27: ...iod of time dust may block the air filter at the air intake vent of the S7500E series As a result the heat dissipation of the system may be affected You are recommended to clean the air filter every three months Air filters are optional accessories Since the air flows up from the bottom air filters for the S7506E V different from those for the other models are installed on the front and rear sides...

Страница 28: ... Yes LSQ1SRP1CB0 Salience VI Turbo No No Yes No Yes Yes Yes LSQ1MPUB0 Salience VI Lite No No Yes No Yes Yes Yes LSQ1SRPD0 Salience VI Plus No No Yes No Yes Yes Yes LSQ1SRP12GB0 Salience VI GE No No Yes No Yes Yes Yes The S7500E series except the S7503E S are a dual SRPU system The SRPUs in a chassis must be of the same type LSQ1MPUA0 SRPU Applicable model S7502E Technical specifications Table 1 16...

Страница 29: ...e length of the handle Panel and LEDs Figure 1 20 shows the front panel of the LSQ1MPUA0 Figure 1 20 Front panel of the LSQ1MPUA0 1 CF card slot and CFS LED 2 Console port 3 10 100Base TX management port and its LEDs 4 Power and fan tray status LEDs 5 LPU status LEDs 6 ACTIVE LED of LSQ1MPUA0 7 RESET button On board interfaces z CF card slot The CF card slot can accommodate a standard CF card Type...

Страница 30: ...ent port Using an RJ 45 connector the 10 100Base TX management port can be connected to a local PC for switch program loading and switch debugging or connected to a remote NMS for remote management Table 1 19 Specifications of the 10 100Base TX management port Item Specifications Connector type RJ 45 Number of connectors 1 Transmission speed and type 10 100 Mbps half full duplex Cable medium and m...

Страница 31: ...rate normally z OFF The fans are faulty or out of position FAIL z ON The fans are faulty or out of position z OFF The fans operate normally z LPU status LEDs SLOT2 SLOT3 MPU SLOT2 and SLOT3 The LEDs show the status of the LPUs in slot 2 and slot 3 MPU The LEDs show the status of the LSQ1MPUA0 itself Table 1 23 Description of LPU status LEDs LED Description RUN z ON OFF The LPU is faulty or out of ...

Страница 32: ...ion z One 10 100Base TX management port z Sixteen 1000Base X SFP 100Base FX SFP ports z Eight Combo ports each of which consists of a 10 100 1000Base T port and an SFP port The two ports comprising a Combo port cannot operate at the same time For the pairings of the SFP ports and 10 100 1000Base T ports refer to Table 1 26 Power consumption 25 W to 45 W Panel and LEDs Figure 1 21 shows the front p...

Страница 33: ... 10 100 1000Base T ports for the Combo ports Table 1 26 Pairings of the SFP ports and the 10 100 1000Base T ports for the Combo ports 1000Base X SFP 100Base FX SFP port number 10 100 1000Base T port number 17 25 18 26 19 27 20 28 21 29 22 30 23 31 24 32 z In a Combo port only one of the 1000Base X SFP 100Base FX SFP port and the 10 100 1000Base T port can be used at a time z The 1000Base X SFP 100...

Страница 34: ...to an ASCII terminal z It can be connected to the serial port of a local or remote through a pair of modems PC running terminal emulation program z 10 100Base TX management port Using an RJ 45 connector the interface can be connected through a common asynchronous serial cable directly to a computer for switch program loading and switch debugging or to a remote NMS for remote management Table 1 29 ...

Страница 35: ...ule is faulty or out of position FAIL z ON At least one power module is faulty or switched off z OFF The power modules are operational or out of position z Fan status LEDs FAN The LEDs shows the status of the fan tray Table 1 32 Description of the fan status LEDs LED Description OK z ON The fans operate normally z OFF The fans are faulty or out of position FAIL z ON The fans are faulty or out of p...

Страница 36: ...ecifications CPU MIPS64 400 MHz Boot ROM 4 MB Flash memory 64 MB DDR SDRAM 512 MB Dimensions H W D 45 377 355 mm 1 77 14 84 13 98 in Ports z One console port used for local or remote configuration and management of the switch through a dialup connection z One 10 100Base TX management port z Twenty 10 100 1000Base T ports z Four Combo ports each of which consists of a 10 100 1000Base T port and an ...

Страница 37: ...connectors z 4 Combo connectors Pluggable module type z Gigabit SFP modules z 100 Mbps SFP modules For details refer to Appendix A List of Pluggable Optical Modules The LSQ1CGV24PSC0 provides two expansion slots SLOT0 and SLOT1 for installing subcards After a subcard is inserted into one of the slots the 10 100 1000Base T ports numbered 25 through 28 cannot be used For the installation procedure a...

Страница 38: ...ating normally z The port is invalid LEDs of ports numbered 25 and 26 indicate subcard 0 LEDs of ports numbered 27 and 28 indicate subcard 1 For example after subcard 0 is installed the four LEDs are steady yellow When the subcard operates normally LEDs of ports numbered 25 and 26 become blinking yellow while LEDs of ports numbered 27 and 28 are still steady yellow The status of the LEDs indicates...

Страница 39: ... a maximum transmission distance of 100 m 328 08 ft Function Used for switch software upgrade and network management Table 1 41 describes the status LEDs of the 10 100Base TX management port Table 1 41 Description of the status LEDs of the 10 100Base TX management port LED Description LINK z OFF No link is present z ON A link is present ACT z OFF No data is being transmitted or received z Blinking...

Страница 40: ...UN z ON OFF The LPU is faulty or out of position z Blinking The LPU is operating normally ALM z OFF The LPU is operational or out of position z ON The LPU is faulty If the RUN LED flashes at a high frequency the card is in the startup process but is not operational yet At system startup the ALM LED will be ON for a while but it does not mean that the card is faulty RESET button A reset button is p...

Страница 41: ...XFP ports and LEDs 3 Console port 4 10 100Base TX management port and its LEDs 5 Power and fan tray status LEDs 6 LPU status LEDs 7 ACTIVE LED of LSQ1SRP2XB0 8 RESET button On board interfaces z CF card slot The CF card slot can accommodate a standard CF card Type I or Type II where you can store host software and logs and thus upgrade software conveniently The CF card is hot swappable Table 1 46 ...

Страница 42: ... the console port Item Specifications Connector type RJ 45 Number of connectors 1 Interface standard Asynchronous EIA TIA 232 Baud rate 115200 bps 9600 bps by default Transmission distance 15 m 49 21 ft Functions z It can be connected to an ASCII terminal z It can be connected to a serial port of a local or remote through a pair of modems PC running terminal emulation program z 10 100Base TX manag...

Страница 43: ...wer module is faulty or out of position FAIL z ON At least one power module is faulty or switched off z OFF The power modules are operational or out of position z Fan status LEDs FAN The LEDs show the status of the fan tray Table 1 53 Description of the fan status LEDs LED Description OK z ON The fans operate normally z OFF The fans are faulty or out of position FAIL z ON The fans are faulty or ou...

Страница 44: ...LSQ1SRPA0 Applicable model S7506E S Technical specifications Table 1 55 Technical specifications of the LSQ1SRPA0 Item Specifications CPU MIPS64 400 MHz Boot ROM 4 MB Flash memory 64 MB DDR SDRAM 512 MB Dimensions H W D 45 377 355 mm 1 77 14 84 13 98 in Ports z One console port used for local or remote configuration and management of the switch through a dialup connection z One 10 100Base TX manag...

Страница 45: ... 100Base TX management port Using an RJ 45 connector the 10 100Base TX management port can be connected to a local PC for switch program loading and switch debugging or connected to a remote NMS for remote management Table 1 57 Specifications of the 10 100Base TX management port Item Specifications Connector type RJ 45 Number of connectors 1 Transmission speed and type 10 100 Mbps half full duplex...

Страница 46: ...IL z ON The fans are faulty or out of position z OFF The fans operate normally z LPU status LEDs SLOT0 through SLOT7 SLOT0 through SLOT7 The LPU status LEDs indicate the statuses of the LPUs seated in the eight slots Table 1 61 Description of LPU status LEDs LED Description RUN z ON OFF The LPU is faulty or out of position z Blinking The LPU is operating normally ALM z OFF The LPU is operational o...

Страница 47: ...p connection z One 10 100Base TX management port Power consumption 42 W to 50 W Panel and LEDs Figure 1 25 shows the front panel of the LSQ1SRPB0 Figure 1 25 Front panel of the LSQ1SRPB0 1 CF card slot and CFS LED 2 Console port 3 10 100Base TX management port and its LEDs 4 Power and fan status LEDs 5 LPU status LEDs 6 ACTIVE LED of LSQ1SRPB0 7 RESET button On board interfaces z CF card slot The ...

Страница 48: ... 21 ft Functions z It can be connected to an ASCII terminal z It can be connected to the serial port of a local or remote through a pair of modems PC running terminal emulation program z 10 100Base TX management port Using an RJ 45 connector the 10 100Base TX management port can be connected to a local PC for switch program loading and switch debugging or connected to a remote NMS for remote manag...

Страница 49: ...modules are faulty or out of position FAIL z ON At least one power module is faulty or switched off z OFF The power modules are operational or out of position z Fan status LEDs FAN The LEDs show the status of the fan tray Table 1 68 Description of the fan status LEDs LED Description OK z ON The fans operate normally z OFF The fans are faulty or out of position FAIL z ON The fans are faulty or out ...

Страница 50: ... you to reset the card when necessary Salience VI Turbo SRPU LSQ1SRP1CB0 Applicable models z S7503E z S7506E z S7510E z S7506E V Technical specifications Table 1 70 Technical specifications of LSQ1SRP1CB0 Item Specifications CPU MIPS64 600 MHz Boot ROM 512 KB Flash memory 64 MB DDR SDRAM 512 MB Dimensions H W D 45 377 355 mm 1 77 14 84 13 98 in Interfaces z One CF card slot z One console port used...

Страница 51: ...can be connected through a common asynchronous serial cable directly to a computer for system debugging configuration maintenance management and host software loading or to a modem for remote system debugging configuration maintenance and management Table 1 72 Specifications of the console port Item Specifications Connector type RJ 45 Number of connectors 1 Interface standard Asynchronous EIA TIA ...

Страница 52: ... transmitted or received System LEDs z System status LEDs The LEDs on the card panel indicate the statuses of the power modules fans LPUs seated in the twelve slots and LSQ1SRP1CB0 itself z Power status LEDs PWR The power status LEDs show the status of the power modules Table 1 75 Description of the power status LEDs LED Description OK z ON The power modules operate normally z OFF The power module...

Страница 53: ... shows the active standby status of the LSQ1SRP1CB0 If the ACTIVE LED is ON the LSQ1SRP1CB0 is active if OFF the LSQ1SRP1CB0 is standby RESET button A reset button is provided on the LSQ1SRP1CB0 for you to reset the card when necessary Salience VI Lite SRPU LSQ1MPUB0 Applicable models z S7503E z S7506E z S7510E z S7506E V Technial specifications Table 1 78 Technical specifications of the LSQ1MPUB0...

Страница 54: ...and host software loading or to a modem for remote system debugging configuration maintenance and management Table 1 79 Specifications of the console port Item Specifications Connector type RJ 45 Number of connectors 1 Interface standard Asynchronous EIA TIA 232 Baud rate 115200 bps 9600 bps by default Transmission distance 15 m 49 21 ft Functions z It can be connected to an ASCII terminal z It ca...

Страница 55: ...les fans LPUs seated in the twelve slots and LSQ1MPUB0 itself z Power status LEDs PWR The power status LEDs show the status of the power modules Table 1 82 Description of the power status LEDs LED Description OK z ON The power modules operate normally z OFF The power module is faulty or out of position FAIL z ON At least one power module is faulty or out of position z OFF The power modules are ope...

Страница 56: ...SQ1MPUB0 If the ACTIVE LED is ON the LSQ1MPUB0 is active if OFF the LSQ1MPUB0 is standby RESET button A reset button is provided on the LSQ1MPUB0 for you to reset the card when necessary Salience VI Plus SRPU LSQ1SRPD0 Applicable models z S7503E z S7506E z S7510E z S7506E V Technial specifications Table 1 85 Technical specifications of the LSQ1SRPD0 Item Specifications CPU MIPS64 600 MHz Boot ROM ...

Страница 57: ...and host software loading or to a modem for remote system debugging configuration maintenance and management Table 1 86 Specifications of the console port Item Specifications Connector type RJ 45 Number of connectors 1 Interface standard Asynchronous EIA TIA 232 Baud rate 115200 bps 9600 bps by default Transmission distance 15 m 49 21 ft Functions z It can be connected to an ASCII terminal z It ca...

Страница 58: ...modules fans LPUs seated in the twelve slots and LSQ1SRPD0 itself z Power status LEDs PWR The power status LEDs show the status of the power modules Table 1 89 Description of the power status LEDs LED Description OK z ON The power modules operate normally z OFF The power module is faulty or out of position FAIL z ON The power module is faulty or out of position z OFF The power modules are operatio...

Страница 59: ...LED is ON the LSQ1SRPD0 is active if OFF the LSQ1SRPD0 is standby RESET button A reset button is provided on the LSQ1SRPD0 for you to reset the card when necessary Salience VI GE SRPU LSQ1SRP12GB0 Applicable models z S7503E z S7506E z S7510E z S7506E V Technial specifications Table 1 92 Technical specifications of the LSQ1SRP12GB0 Item Specifications CPU Dual CPUs z MIPS64 600 MHz z MIPS64 400 MHz...

Страница 60: ... store host software and logs and thus upgrade software conveniently The CF card is hot swappable Table 1 93 describes the CFS LED on the right of the CF card Table 1 93 Description of the CFS LED Status Description OFF No CF card is in position ON The CF card is in position z 1000Base X SFP 100Base FX SFP ports Table 1 94 presents the specifications of the 1000Base X SFP 100Base FX SFP ports Tabl...

Страница 61: ...ault Transmission distance 15 m 49 21 ft Functions z It can be connected to an ASCII terminal z It can be connected to a serial port of a local or remote through a pair of modems PC running terminal emulation program z 10 100Base TX management port Using an RJ 45 connector the 10 100Base TX management port can be connected to a local PC for switch program loading and switch debugging or connected ...

Страница 62: ...The power module is faulty or out of position FAIL z ON The power module is faulty or out of position z OFF The power modules are operational or out of position z Fan status LEDs FAN The fan status LEDs show the status of the fan tray Table 1 100 Description of the fan status LEDs LED Description OK z ON The fans operate normally z OFF The fans are faulty or out of position FAIL z ON The fans are ...

Страница 63: ...2GB0 for you to reset the card when necessary LPUs LSQ1FP48SA0 Introduction The LSQ1FP48SA0 provides forty eight 100Base FX SFP ports Table 1 102 Technical specifications of the LSQ1FP48SA0 Item Specifications CPU MIPS64 400 MHz Boot ROM 512 KB DDR SDRAM 512 MB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 34 W to 85 W Connector type LC Number of ports 48 Interface speed 100...

Страница 64: ... Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 30 W to 35 W Connector type RJ 45 Number of ports 48 Port transmission speed and type z 10 100 Mbps half full duplex z MDI MDI X auto sensing Cable medium and maximum transmission distance Category 5 twisted pair with the maximum transmission distance of 100 m 328 08 ft Panel and LEDs Figure 1 31 LSQ1FV48SA0 panel Each auto sens...

Страница 65: ... Port transmission speed 1000 Mbps Pluggable module type Gigabit SFP modules For details refer to Appendix A List of Pluggable Optical Modules Panel and LEDs Figure 1 32 LSQ1GP12EA0 panel Each 1000Base X SFP port has a green LED Table 1 107 describes the LED Table 1 107 Description of the LED of each port on the LSQ1GP12EA0 panel Status Meaning OFF No link is present ON A link is present Blinking ...

Страница 66: ...ptical Modules Panel and LEDs Figure 1 33 LSQ1GP12SC0 panel Each 1000Base X SFP 100Base FX SFP port has a green LED Table 1 109 describes the LED Table 1 109 Description of the LED of each port on the LSQ1GP12SC0 panel Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received LSQ1GP24SC0 Introduction The LSQ1GP24SC0 provides twenty four 1000Base X SF...

Страница 67: ...describes the LED Table 1 111 Description of the LED of each port on the LSQ1GP24SC0 panel Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received LSQ1GP48SC0 Introduction The LSQ1GP48SC0 provides forty eight 1000Base X SFP 100Base FX SFP ports Table 1 112 Technical specifications of the LSQ1GP48SC0 Item Specifications CPU MIPS64 400 MHz Boot ROM 5...

Страница 68: ...link is present Blinking Data is being transmitted or received LSQ1GP48SD0 Introduction The LSQ1GP48SD0 provides forty eight 1000Base X SFP 100Base FX SFP ports Table 1 114 Technical specifications of the LSQ1GP48SD0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 44 W to 95 W Connector type LC Number of ports 4...

Страница 69: ...Base FX SFP ports Table 1 116 Technical specifications of the LSQ1GP48EB0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 43 W to 110 W Connector type LC Number of ports 48 Port transmission speed 1000Base X SFP 100Base FX SFP port 1000 100 Mbps Pluggable module type z Gigabit SFP modules z 100 Mbps SFP modules ...

Страница 70: ...5 mm 1 57 14 84 13 98 in Power consumption 42 W to 50 W Connector type RJ 45 Number of ports 24 Transmission speed and type z 10 100 1000 Mbps half full duplex z MDI MDI X auto sensing Cable medium and maximum transmission distance Category 5 twisted pair cables with a maximum transmission distance of 100 m 328 08 ft Panel and LEDs Figure 1 38 LSQ1GT24SC0 panel Each auto sensing 10 100 1000Base T ...

Страница 71: ... 1000Base X SFP 100Base FX SFP port 1000 100 Mbps Transmission speed and type 10 100 1000Base T port z 10 100 1000 Mbps half full duplex z MDI MDI X auto sensing Pluggable module type z Gigabit SFP modules z 100 Mbps SFP modules z Auto sensing 10 100 1000Base T ports For details refer to Appendix A List of Pluggable Optical Modules The LSQ1GV24PSC0 provides two expansion slots SLOT0 and SLOT1 for ...

Страница 72: ...mitted or received Table 1 123 describes the LEDs for ports numbered 25 through 28 when one or more subcards are installed Table 1 123 Description of LEDs for ports 25 through 28 with subcards installed Color Status Meaning ON z The port is invalid z The subcard is being enabled or cannot be enabled Yellow Blinking The subcard is operating normally LEDs of ports numbered 25 and 26 indicate subcard...

Страница 73: ...000 Mbps half full duplex z MDI MDI X auto sensing Cable medium and maximum transmission distance Category 5 twisted pair cables with a maximum transmission distance of 100 m 328 08 ft Panel and LEDs Figure 1 40 LSQ1GV48SA0 panel Each auto sensing 10 100 1000Base T port has a green LED Table 1 125 describes the LED Table 1 125 Description of the LED of each port on the LSQ1GV48SA0 panel Status Mea...

Страница 74: ... distance of 100 m 328 08 ft Panel and LEDs Figure 1 41 LSQ1GV48SC0 panel Each 10 100 1000Base T auto sensing port has a green LED Table 1 127 describes the LED Table 1 127 Description of the LED of each port on the LSQ1GV48SC0 panel Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received LSQ1GV48SD0 Introduction The LSQ1GV48SD0 provides 48 auto se...

Страница 75: ... Table 1 129 Description of the LED of each port on the LSQ1GV48SD0 panel Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received LSQ1P24XGSC0 Introduction The LSQ1P24XGSC0 provides twenty four 1000Base X SFP 100Base FX SFP ports and two 10GBase R XFP ports Table 1 130 Technical specifications of the LSQ1P24XGSC0 Item Specifications CPU MIPS64 400 ...

Страница 76: ...inking Data is being transmitted or received Each 10GBase R XFP port has two LEDs Table 1 132 describes the LEDs Table 1 132 Description of the LEDs of the 10GBase R XFP port LED Description LINK z OFF No link is present z ON A link is present ACT z OFF No data is being transmitted or received z Blinking Data is being transmitted or received LSQ1T24XGSC0 Introduction The LSQ1T24XGSC0 provides 24 a...

Страница 77: ... has a green LED Table 1 134 describes the LED Table 1 134 Description of the LED of the auto sensing 10 100 1000Base T port Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received Each 10GBase R XFP port has two LEDs Table 1 135 describes the LEDs Table 1 135 Description of the LEDs of the 10GBase R XFP port LED Description LINK z OFF No link is p...

Страница 78: ...SQ1TGX1EA0 panel The 10GBase R XFP port has two green LEDs Table 1 137 describes the LEDs Table 1 137 Description of the LEDs of the 10GBase R XFP port LED Description LINK z OFF No link is present z ON A link is present ACT z OFF No data is being transmitted or received z Blinking Data is being transmitted or received LSQ1TGX2SC0 Introduction The LSQ1TGX2SC0 provides two 10GBase R XFP ports Table...

Страница 79: ...cription LINK z OFF No link is present z ON A link is present ACT z OFF No data is being transmitted or received z Blinking Data is being transmitted or received LSQ1TGX2SD0 Introduction The LSQ1TGX2SD0 provides two 10GBase R XFP ports Table 1 140 Technical specifications of the LSQ1TGX2SC0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 ...

Страница 80: ... z Blinking Data is being transmitted or received LSQ1TGX2EB0 Introduction The LSQ1TGX2EB0 provides two 10GBase R XFP ports Table 1 142 Technical specifications of the LSQ1TGX2EB0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 46 W to 65 W Connector type LC Number of ports 2 Interface speed 10 Gbps Pluggable mo...

Страница 81: ...n The LSQ1TGX4SD0 provides four 10GBase R XFP ports Table 1 144 Technical specifications of the LSQ1TGX4SD0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 53 W to 80 W Connector type LC Number of ports 4 Interface speed 10 Gbps Pluggable module type XFP modules For details refer to Appendix A List of Pluggable ...

Страница 82: ...RAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 53 W to 80 W Connector type LC Number of ports 4 Interface speed 10 Gbps Pluggable module type XFP modules For details refer to Appendix A List of Pluggable Optical Modules Panel and LEDs Figure 1 50 LSQ1TGX4EB0 panel Each 10GBase R XFP port has two green LEDs Table 1 147 describes the LEDs on the LSQ1TGX4EB0 panel Table...

Страница 83: ...XFP modules For details refer to Appendix A List of Pluggable Optical Modules Panel and LEDs Figure 1 51 LSQ1TGX8SD0 panel Each 10GBase R XFP port has two green LEDs Table 1 149 describes the LEDs on the LSQ1TGX8SD0 panel Table 1 149 Description of the LEDs of the 10GBase R XFP port LED Description LINK z OFF No link is present z ON A link is present ACT z OFF No data is being transmitted or recei...

Страница 84: ... Gigabit SFP modules z 100 Mbps SFP modules z Auto sensing 10 100 1000Base T ports For details refer to Appendix A List of Pluggable Optical Modules Table 1 151 shows the pairings of the SFP and the 10 100 1000Base T ports for the Combo ports Table 1 151 Pairings of the SFP ports and the 10 100 1000Base T ports for the Combo ports 1000Base X SFP 100Base FX SFP port number 10 100 1000Base T port nu...

Страница 85: ...l specifications of the LSQ1GP24TSD0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 47 W to 75 W Connector type z LC z RJ 45 Number of ports z 16 SFP ports z 8 Combo ports 1000Base X SFP 100Base FX SFP port 1000 100 Mbps Transmission speed and type 10 100 1000Base T port z 10 100 1000 Mbps half full duplex z MD...

Страница 86: ...an be used at a time z The 1000Base X SFP 100Base FX SFP port of a Combo port does not support the pluggable SFP GE T module Panel and LEDs Figure 1 53 LSQ1GP24TSD0 panel Each Ethernet port has one green LED Table 1 155 describes the LED Table 1 155 Description of the LED of each Ethernet port Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received...

Страница 87: ...le module type z Gigabit SFP modules z 100 Mbps SFP modules For details refer to Appendix A List of Pluggable Optical Modules Table 1 157 shows the pairings of the SFP and the 10 100 1000Base T ports for the Combo ports Table 1 157 Pairings of the SFP ports and the 10 100 1000Base T ports for the Combo ports 1000Base X SFP 100Base FX SFP port number 10 100 1000Base T port number 17 25 18 26 19 27 ...

Страница 88: ...9 Technical specifications of the LSQ1GP24TXSD0 Item Specifications CPU MIPS64 1 GHz Boot ROM 4 MB DDR SDRAM 1 GB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 54 W to 95 W Connector type z LC z RJ 45 Number of ports z 16 SFP ports z 8 Combo ports z 2 XFP ports 10GBase R XFP port 10 Gbps 1000Base X SFP 100Base FX SFP port 1000 100 Mbps Transmission speed and type 10 100 1000...

Страница 89: ...e 10 100 1000Base T port can be used at a time z The 1000Base X SFP 100Base FX SFP port of a Combo port does not support the pluggable SFP GE T module Panel and LEDs Figure 1 55 LSQ1GP24TXSD0 panel Each 10 100 1000Base T port has one green LED Table 1 161 describes the LED Table 1 161 Description of the LED of each 10 100 1000Base T port Status Meaning OFF No link is present ON A link is present B...

Страница 90: ...Q1GV40PSC0 Item Specifications CPU MIPS64 400 MHz Boot ROM 512 KB DDR SDRAM 512 MB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 41 W to 95 W Connector type z SFP z RJ 45 Number of ports z 8 SFP ports z 40 RJ 45 ports Interface speed z 1000Base T port 10 100 1000 Mbps z 1000Base X SFP 100Base FX SFP port 100 1000 Mbps Pluggable module type z Gigabit SFP modules z 100 Mbps SF...

Страница 91: ...12 KB DDR SDRAM 512 MB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 33 W to 40 W Connector type z EPON port SC z 1000Base X SFP 100Base FX SFP port LC Number of ports z 4 EPON ports z 8 SFP ports Interface speed z EPON port 1000 Mbps z 1000Base X SFP 100Base FX SFP port 1000 100 Mbps Pluggable module type z Pluggable modules for EPON ports z Gigabit SFP modules z 100 Mbps S...

Страница 92: ...s being transmitted or received LSQ1PT8PSC0 Introduction The LSQ1PT8PSC0 provides eight EPON ports and eight 1000Base X SFP 100Base FX SFP ports Table 1 168 Technical specifications of the LSQ1PT8PSC0 Item Specifications CPU MIPS64 400 MHz Boot ROM 512 KB DDR SDRAM 512 MB Dimensions H W D 40 377 355 mm 1 57 14 84 13 98 in Power consumption 38 W to 45 W Connector type z EPON port SC z 1000Base X SF...

Страница 93: ...1000Base X SFP 100Base FX SFP port Table 1 170 Description of the LED of each 1000Base X SFP 100Base FX SFP port Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received LSQ1PT16PSC0 Introduction The LSQ1PT16PSC0 provides sixteen EPON ports and eight 1000Base X SFP 100Base FX SFP ports Table 1 171 Technical specifications of the LSQ1PT16PSC0 Item Sp...

Страница 94: ...LED status EPON port status Description OFF Down No SFP module is installed OFF Up An SFP module is installed but no ONU is registered ON Up An ONU is registered Likewise each 1000Base X SFP 100Base FX SFP port has a green LED Table 1 173 describes the LED of each 1000Base X SFP 100Base FX SFP port Table 1 173 Description of the LED of each 1000Base X SFP 100Base FX SFP port Status Meaning OFF No ...

Страница 95: ...each 100Base FX SFP port on the LSQ2FP48SA0 Table 1 175 Description of the LED of the 100Base FX SFP port Status Meaning OFF No link is present ON A link is present Blinking Data is being transmitted or received LSQ2FT48SA0 The LSQ2FT48SA0 provides 48 auto sensing 10 100Base T ports Table 1 176 Technical specifications of the LSQ2FT48SA0 Item Specifications CPU MIPS32 264 MHz Boot ROM 4 MB DDR SDR...

Страница 96: ... various requirements of users You can purchase the switch and SRPU modules as needed Purchasing a Switch While purchasing a switch take the following factors into consideration Networking requirements z Location of this switch in the networking scenario and the role it plays z How much the backplane capacity matches the network traffic z Necessary processing and connecting capability for uplink a...

Страница 97: ...r You can use PSR650 power modules in combination with PWR SPA power module adapters to power a switch such as the S7503E S7506E or S7506E V with system power consumption lower than 650 W You can choose to use one or two PWR SPA power modules Purchasing SRPUs Table 1 180 List of SRPUs for the S7500E series Type Quantity Remarks LSQ1MPUA0 1 to 2 Required For S7502E only LSQ1CGP24TSC0 1 Required For...

Страница 98: ...ptional LSQ1GV48SD0 Determined by the number of LPU slots in the chassis Optional LSQ1P24XGSC0 Determined by the number of LPU slots provided by the chassis Optional LSQ1T24XGSC0 Determined by the number of LPU slots in the chassis Optional LSQ1TGX1EA0 Determined by the number of LPU slots in the chassis Optional LSQ1TGX2SC0 Determined by the number of LPU slots in the chassis Optional LSQ1TGX2SD0...

Страница 99: ...Quantity Remarks H3C S7502E air filter 0 to 1 Optional H3C S7503E S air filter 0 to 1 Optional H3C S7503E air filter 0 to 1 Optional H3C S7506E S air filer 0 to 1 Optional H3C S7506E air filter 0 to 1 Optional H3C S7510E air filter 0 to 1 Optional H3C S7506E V air filter 0 to 1 Optional Purchasing Fan Trays Table 1 183 List of fan trays for the S7500E series Description Quantity Remarks H3C S7502E...

Страница 100: ...slave power management micro electronic component Type 1 LSQ1GV48SC0 48 port PoE master slave power management micro electronic component Type 1 LSQ1GV40PSC0 48 port PoE master slave power management micro electronic component Type 1 PoE power types include z Type 1 offers power 0 to 15 4 W voltage 44 V to 57 V and maximum current 350 mA and provides power supply for powered devices PDs of class 0...

Страница 101: ...2 1 Anti static Safety 2 2 Laser Safety 2 2 Examining Installation Site 2 2 Temperature Humidity Requirements 2 3 Cleanness Requirements 2 3 Anti static Requirements 2 4 Grounding Requirements 2 4 Power Supply Requirements 2 4 Installation Planning 2 4 Installation Space Requirement 2 4 Rack Mounting Requirements 2 4 Installation Tools 2 5 ...

Страница 102: ...r off at once in case accident occurs z Unplug all the power cables and external cables before moving the chassis z Better not maintain the equipment alone when it has been powered by electricity z Never assume that power is disconnected from a circuit Always check z Do not place the switch on a moist area and avoid liquid flowing into the switch Handling Safety The S7500E series are rather big an...

Страница 103: ...r clip Step 4 Make sure the ESD preventive wrist strap is well grounded An ESD preventive wrist strap is shipped with the S7500E series There is a jack for the ESD preventive wrist strap on the chassis of the S7500E series For safety case check the resistance of the ESD preventive wrist strap The resistance between human body and the ground should be 1 to 10M ohm Laser Safety Some LPUs of the S750...

Страница 104: ...2 0 F to 113 0 F 40 0 C to 70 0 C 40 0 F to 158 0 F 10 to 95 noncondensing 5 to 95 noncondensing Cleanness Requirements Dust is a big harm for the normal operation of the switch The indoor dust accumulated on the chassis can cause electrostatic adsorption resulting in the poor contact of the connector or metal contact point This happens more frequently when the relative indoor humidity is low whic...

Страница 105: ... system for the switch and the grounding resistance should be less than 1 5 ohm Power Supply Requirements For the power supply requirements refer to section 1 2 3 Power Supply System in Chapter 1 Product Overview Installation Planning Since the S7500E series are a kind of complex equipment it is necessary to make a good plan and arrangement concerning installation position networking mode power su...

Страница 106: ...le ended double offset ring wrench 10 12 or double open end wrench 10 12 Small tools Sharp nose pliers diagonal pliers vices hand held electrical drill file handsaw crowbar and rubber hammer General tools Auxiliary tools Hair brush tweezers paper knife hand bellows electric iron solder wire fork and ladder Special tools ESD preventive wrist glove cable stripper crimping pliers RJ 45 crimping plier...

Страница 107: ...wer Cable 3 6 Connecting the AC Power Cable 3 6 Connecting the DC Power Cables 3 9 Connecting PoE Power Cables 3 10 Connecting Interface Cables 3 13 Connecting the Console Cable 3 13 Connecting the AUX Cable Optional 3 14 Connecting the COM Cable 3 14 Connecting Category 5 Cables 3 14 Connecting Fibers 3 16 Cabling 3 17 Workbench Mounted Switch 3 17 Rack Mounted Switch 3 17 General Cabling Require...

Страница 108: ...3 1 Installation flowchart Connect the power cables Mount the switch to the designated position Install modules of the switch Connect the interface cables Route and bind the cables Check the installation Start End Connect the grounding cables Connect the power cables Mount the switch to the designated position Install modules of the switch Connect the interface cables Route and bind the cables Che...

Страница 109: ...way 1 Before installation ensure that z The N68 cabinet has been well fixed The installation position for the switch has been well arranged and there is no obstacle around z The switch is ready for installation and has been carried to a place near the cabinet and convenient for moving z An air filter if required is already installed because it is inconvenient to mount it onto the switch that is in...

Страница 110: ...connect the grounding cable properly when installing and using a switch Common grounding environment 1 Remove the grounding screw from the lower right part of the rear panel of the switch chassis 2 Set the grounding cable connector provided together with the switch around the grounding screw 3 Fasten the grounding screw in the hole on the chassis 4 Connect the other end of the grounding cable to t...

Страница 111: ...he grounding body is allowed to be buried you can simply hammer an angle iron or steel pipe no shorter than 0 5m into the earth In this case the yellow green protection grounding cable should be welded with the angle iron steel pipe and the joint should be processed against eroding Figure 3 4 Connect the protection grounding cable to the grounding body nearby Power input Ethernet Switch Grounding ...

Страница 112: ...d through the return RTN wire of the DC power supply In this case make sure the RTN wire has been well grounded from the DC egress of the DC power cabinet Figure 3 6 Ground a DC powered Ethernet switch through the RTN wire of a power cabinet DC power input Ethernet Switch RTN 48V AC DC power box 48V strip RTN strip PGND strip Ground Grounding screw Installing Switch Modules For the procedure for i...

Страница 113: ...r the PSR320 A II To connect the AC power cable for the PSR320 A proceed as follows 1 Plug one end of the AC power cable into the socket on the switch and lock the cable with the power cable retainer 2 Plug the other end into the AC power busbar which is connected to the AC power supply in the equipment room PSR650 A power module Refer to section PSR320 A power module on page 3 6 ...

Страница 114: ...0 ACV power module There are two AC power inputs on the PSR2800 ACV power module one for system power and the other for PoE power The connection of the power cable for each power input is the same as that of the PSR1400 A For the detailed connection method refer to section PSR1400 A power module on page 3 7 PSR6000 ACV power module The PSR6000 ACV is shipped with a power cable retainer suite Apply...

Страница 115: ...ts are connected in the same way The following takes the connection of the power cable for the system power input as an example To connect the AC power cable to the PSR6000 ACV proceed as follows 1 Connect the connector fastened with the retainer suite to the three pronged socket of the power module After that the screw holes on the right part of the retainer suite are aligned with those on the po...

Страница 116: ...20 D Turn off all switches on the switch before connecting the DC power cables To connect the DC power cable for the PSR320 D proceed as follows 1 Remove the protection cover from the power module 2 Loosen the fastening screw on the wiring terminal with a Phillips screwdriver 3 Connect the end of the blue DC power cable marked with to the negative terminal on the power module and fasten the screw ...

Страница 117: ...h a socket wrench M6 and remove the fastening nut spring washer and one flat washer in turn 3 Connect the end of the blue DC power cable marked with to the negative terminals on the power module and fasten the screws 4 Connect the end of the black DC power cable marked with to the RTN terminals on the power module and fasten the screws 5 Put the flat washers and spring washer on the wiring termina...

Страница 118: ...r cables refer to section PSR1400 D power module on page 3 10 In the case of PSR2800 ACV or PSR6000 ACV power modules you can connect the 16 A AC power cables to the PoE input ends of the power modules for PoE input For how to connect the power cables refer to section PSR2800 ACV power module on page 3 7 or PSR6000 ACV power module on page 3 7 z When you use PSR1400 D modules to provide PoE supply...

Страница 119: ...ows the rear panel of an external PoE power supply on the RPS500 A3 Figure 3 15 Rear panel of an external PoE power supply PSE2500 A3 1 AC power input 2 DC power output Figure 3 16 Connect the PoE power cable to the RPS500 A3 as an example Follow these steps to connect the PoE power cables 1 Remove the protection cover from the terminals which are used to connect the external PoE power supply ...

Страница 120: ...lugged into the console port The other end is furnished with a DB 9 female connector You can select either of them based on your actual requirements to fit in with the 9 pin serial interface at the configuration terminal The following figure shows the console cable Figure 3 17 Console cable Table 3 1 Console cable pinouts Pin RJ 45 Signal Pin DB 9 Signal 1 RTS 8 CTS 2 DTR 6 DSR 3 TXD 2 RXD 4 SG 5 ...

Страница 121: ...log Modem Connecting the COM Cable When the S7503E S7506E S7506E V or S7510E provides PoE supply through the PSR1400 D they can monitor the running status of the PoE supply through the PoE monitoring port on the PSR1400 D The PoE monitoring port on the PSR1400 D is an RS 485 port You can select a proper connection method for the RS 485 port according to the type of the PoE monitoring port on the e...

Страница 122: ...ed BIDD Bi directional data cable D Tx Transmit data Rx Receive data BI Bi directional data Table 3 3 RJ 45 MDI X interface pinouts 10Base T 100Base TX 1000Base T Pin Signal Function Signal Function 1 Rx Receive data BIDB Bi directional data cable B 2 Rx Receive data BIDB Bi directional data cable B 3 Tx Send data BIDA Bi directional data cable A 4 Reserved BIDD Bi directional data cable D 5 Reser...

Страница 123: ...system Their application enables the removable connection between optical channel which makes optical system debugging and maintenance more convenient and transit dispatching more flexible Among multiple fiber connectors only SC and LC will be introduced here z SC fiber connector Figure 3 19 SC connector z LC fiber connector Figure 3 20 LC connector Connecting fibers 1 Remove the protective cap fr...

Страница 124: ...rack on the top of the chassis or the cabling rack under the floor Collect all the transit data signal cable connectors and locate them on the floor of the chassis instead of any places outside the chassis for fear of unexpected damage The power cables run out of the front right side of the chassis and either on the cabling rack or in the raised floor as near as possible according to the situation...

Страница 125: ...he radius of the curve at which the cable is bent should be at least five times its diameter z Different cables power cable signal cable grounding cable and so on should run and be bound separately in a cabinet They must not be bound together If they are close to each other you can cable them in a crossing way For parallel cabling the space between power cable and signal cable should be no less th...

Страница 126: ... on the cable channel In the so called right places the running device will not be affected or damaged and the cables will not be damaged either z 220V power cable and 48V power cable cannot be tied on the guides of any mobile components z Keep excessive parts of power cables for those mobile components such as grounding cable of doors to free the cables from possible stress When installing these ...

Страница 127: ...ies Table 3 4 Tie binding parameters Cable bundle diameter Space between bundles 10 mm 0 39 in 80 mm to 150 mm 3 15 in to 5 91 in 10 mm to 30 mm 0 39 in to 1 18 in 150 mm to 200 mm 5 91 in to 7 87 in 30 mm 1 18 in 200 mm to 300 mm 7 87 in to 11 81 in z No cable or bundle can tie a knot z The metal parts of crimping cold pressed terminal blocks such as air switch cannot stretch beyond the blocks Ch...

Страница 128: ...3 21 Table 3 5 Installation checklist Items Normal Abnormal Description ESD preventive wrist strap Console cable Grounding cable Power cable SRPU LPU Fan tray Power module ...

Страница 129: ...figuration Environment Setup 4 1 Setting up Networking Environment 4 1 Connecting the Console Cable 4 1 Setting Terminal Parameters 4 1 Power On Startup 4 4 Check before Power On 4 4 Power On 4 4 Check after Power On Recommended 4 5 Startup Process 4 5 ...

Страница 130: ... of the PC or the terminal where the switch is to be configured Step 2 Connect the RJ 45 connector of the console cable to the console port of the switch Setting Terminal Parameters Parameter requirements z Bits per second 9600 z Data bits 8 z Parity None z Stop bits is 1 z Flow control None z Terminal emulation VT100 We take the PC running Windows XP HyperTerminal as an example to introduce how t...

Страница 131: ...to enter the HyperTerminal window to establish a new connection and the system will pop up the Connection Description dialog box Figure 4 2 Connection description of HyperTerminal Type the name of the new connection and click OK Then there pops up the interface as shown in the following figure Select the serial port to be used from Connect using drop down list box Figure 4 3 Set serial port for Hy...

Страница 132: ...ure 4 4 Set serial port parameters After setting serial port parameters click OK Then the system will enter the HyperTerminal dialogue box as shown in the following figure Figure 4 5 HyperTerminal interface In the above dialogue box select Properties and enter the window Click the Settings tab to set the attributes see the following figure In this interface select the terminal emulation to VT100 a...

Страница 133: ... and grounding cables have been correctly connected z If the voltage of power supply can meet the requirements on the switch z The console cable has been correctly connected The computer or terminal for configuration has been started and the terminal parameter settings have been done Before powering on the switch make sure where the power switch of the equipment room is located so that you will be...

Страница 134: ...ocess As the switch is started the configuration terminal will yield the following output The following information may slightly vary with switch models and software versions Starting RAMLine OK System is booting H3C S7500E BOOTROM Version 206 Copyright c 2004 2008 Hangzhou H3C Technologies Co Ltd Creation date Apr 11 2008 10 15 28 CPU type BCM1125H CPU Clock Speed 600Mhz BUS Clock Speed 66Mhz BOO...

Страница 135: ... to get started The above information indicates the completion of the switch auto booting Press Enter and get the following output By this time you can start configuring the switch H3C H3C S7500E series switches provide a variety of command views For the specific descriptions on the configuration commands and command line interfaces refer to Operation Manual and Command Manual of the H3C S7500E Se...

Страница 136: ...or the Other Models 5 7 Installing Mounting Ears and a Cabling Rack s 5 7 Installing Cabling Racks on the S7506E V 5 8 Installing Mounting Ears and the Cabling Rack on the Other Models 5 8 Installing and Removing Air Filters Optional 5 10 Installing and Removing Air Filters onto from the S7506E V 5 10 Installing and Removing an Air Filter onto from the Other Models 5 11 Installing and Removing a C...

Страница 137: ...dule The power module installation and removal procedures described in this section involve the following two scenarios z Power modules are directly installed to removed from the chassis z Power modules are installed to removed from the chassis with power module adapters In the second scenario you need to install a power module adapter to the chassis first and then install a power module to the po...

Страница 138: ...see callout in Figure 5 1 Since the power module of the S7500E series is heavy you are recommended to grasp the handle of the power module with one hand and hold the bottom with the other while pulling out a power module slowly If you are not going to install a new power module after removing a power module you should install a blank panel for the heat dissipation and dust proof purpose Installing...

Страница 139: ...n backplane To prevent damage to the power module and the connection terminals on the backplane make sure to pull the module out first in case of any misalignment and then push it in again 3 Tighten the captive screws with a screwdriver to secure the power module to the chassis If the captive screws cannot be tightened check whether the power module is properly installed Removing and Installing Ca...

Страница 140: ...ll a new card after removing a card install a blank panel on the slot for the dust proof purpose Installing a Card Install a card in the opposite way you remove it 1 Wear an ESD preventive wrist strap and loosen the captive screws on the blank panel on the slot where the card should be inserted 2 Hold the card by the front panel with one hand and hold the card bottom with the other hand do not tou...

Страница 141: ...ate the fan tray from the backplane to disconnect the power and wait for the fan stops rotating before pulling it out completely Considering that the fan may be still rotating avoid stretching your hands into the fan tray The fan tray handle of the S7506E V is slightly different from those of the S7502E S7503E S S7503E S7506E S S7506E and S7510E The fan tray handles of S7502E S7503E S S7503E S7506...

Страница 142: ... callout in Figure 5 3 3 Grasp the handle to take out the fan tray see callout in Figure 5 3 4 Put the removed fan tray in a package Install a new fan tray soon after removing the old one to ensure that the switch can work normally Installing a fan tray Install a fan tray in the opposite way you remove it 1 Wear an ESD preventive wrist strap take a new fan tray out of a package and insert it along...

Страница 143: ...snaps into the chassis backplane 2 Tighten the captive screws on the fan tray with a screwdriver Installing Mounting Ears and a Cabling Rack s To facilitate installation and cable routing mounting ears and a cabling rack are shipped together with the S7500E series but they are separated Therefore you first need to install the cabling rack on a mounting ear For the S7506E V it is unnecessary to ins...

Страница 144: ...he place where it should be installed on the chassis and align the screws with the crew holes 2 Tighten the screws to fix the cabling racks There are two cabling racks upward cabling rack and downward cabling rack However they are installed in the same way Installing Mounting Ears and the Cabling Rack on the Other Models Installing the cabling rack onto a mounting ear As shown in Figure 5 6 instal...

Страница 145: ...ing ears and cabling rack 1 Mounting ear and cabling rack 2 Mounting ear Follow these steps to install the mounting ears and cabling rack on a model other than the S7506E V 1 Face the slots of the switch 2 Attach the mounting ear with the cabling rack installed to the left opposite side to the fan tray of the switch Attach the mounting ear without any cabling rack to the right side of the switch ...

Страница 146: ...an air filter closely against the air intake vent at the back of the chassis and align the captive screws with the screw holes see callout in Figure 5 8 2 Tighten the captive screws to fix the air filter see callout in Figure 5 8 There is also an air filter on the front of the chassis and it is installed in the same way Removing air filters Remove the air filters in the opposite way you install th...

Страница 147: ... along the clearance between the upper and lower metal bars and the chassis at the back of the chassis see callout in Figure 5 10 3 Tighten the captive screws to fix the air filter see callout in Figure 5 10 Removing the air filter Remove the air filter in the opposite way you install it 1 Loosen the captive screws on the air filter 2 Pull the air filter out of the chassis slowly Installing and Re...

Страница 148: ...2 Removing the CF Card Follow these steps to remove the CF card 1 Execute the umount command in user view to unmount the CF card If you want to use the CF card after you execute the umount command you can execute the mount command in user view to mount the CF card again For detailed descriptions about the mount and umount commands refer to the file system management commands in S7500E Series Ether...

Страница 149: ...CF card To avoid damaging the hardware or the file system on the CF card do not remove the CF card when the switch is booting or the CFS LED is flashing Put the removed CF card in an antistatic bag to protect it against ESD damage ...

Страница 150: ...ing Through the Console Port Using XMODEM 6 6 Setting the Main and Backup Host Software Through the Boot Menu 6 11 Updating Boot ROM Through a File on the Flash 6 12 Upgrading Through Command Lines 6 14 Upgrading Using FTP 6 14 Upgrading Using TFTP 6 15 Examples of Upgrading Boot ROM and Host Software of the Dual SRPUs 6 16 Upgrading Boot ROM and Host Software Through Command Lines 6 16 Upgrading ...

Страница 151: ... and standby SRPUs upgrade the software in the same way that is upgrade the software on both the active and standby SRPUs either through command lines or through the boot menu z Since upgrading through command lines affects the services of the S7500E series less significantly than upgrading through the boot menu the former is recommended Upgrading Through the Boot Menu You can download the host so...

Страница 152: ... CPLD selftest OK FPGA selftest OK The switch Mac address is 0000 FC00 7506 The above information may vary slightly with the models of S7500E series Press Ctrl B to enter Boot Menu 5 Press Ctrl B The system prompts you to input the Boot ROM password Password To enter the boot menu press Ctrl B within 5 seconds after Press Ctrl B to enter Boot Menu is prompted Otherwise the system will start execut...

Страница 153: ...be downloaded through the management upgrade Ethernet port the IP address of the PC is required Connect the switch to a PC through the console port the two PCs can be the same one 2 Run the TFTP Server program on the PC connected to the Ethernet port and specify the file directory of the program to be downloaded 3 Run the terminal emulation program on the PC connected to the console port Start the...

Страница 154: ...ation upon the completion of the downloading process Attached TCP IP interface to sbe1 Attaching network interf Prepare for loading OK Loading done Free flash Space 65932288 bytes Writing flash done 1 Set TFTP protocol parameter 2 Set FTP protocol parameter 3 Set XMODEM protocol parameter 0 Return to boot menu Enter your choice 0 3 After the above steps you have completed the downloading of the ho...

Страница 155: ...ter 1 when the system displays Enter your choice 0 5 to enter the download protocol menu BOOT MENU 1 Download application file to device 2 Select application file to boot 3 Display all files in device 4 Delete file from device 5 Modify bootrom password 0 Reboot Enter your choice 0 5 1 4 On the download protocol menu type 2 to select FTP and then press Enter to set the FTP parameters 1 Set TFTP pro...

Страница 156: ...ile transfer protocol widely used due to its simplicity and good performance XMODEM transfers files through the console port supporting data packets of 128 bytes and 1 KB With respect to reliability XMODEM supports checksum CRC and error packet retransmission mechanism Normally the maximum number of transmission attempts is 10 XMODEM transmission is completed by the receiving and sending program T...

Страница 157: ...oot Enter your choice 0 5 1 2 On the download protocol menu type 3 to select XMODEM and press Enter and then the system will prompt you to input the name of the file to be downloaded 1 Set TFTP protocol parameter 2 Set FTP protocol parameter 3 Set XMODEM protocol parameter 0 Return to boot menu Enter your choice 0 4 3 Load File name update app 3 Enter the file name to enter the download baud rate ...

Страница 158: ...em will not display the above information 5 Click Disconnect in the HyperTerminal window to disconnect the HyperTerminal from the switch before setting a baud rate 6 Select File Properties in the HyperTerminal window click Configure in the popup dialog box and select the baud rate of 19200 bps in the console port configuration dialog box Figure 6 1 Properties dialog box ...

Страница 159: ...lays the following information Now please start transfer file with XMODEM protocol If you want to exit Press Ctrl X Downloading CCCCCCCCCCCCCCC 8 Select Transfer Send File in the HyperTerminal window In the popup dialog box shown in the following figure click Browse to select the software you need to download and set the protocol to XMODEM Figure 6 3 Send File dialog box ...

Страница 160: ...CCCCCCCCCCCCCCCCC done Free flash Space 65932288 bytes Writing flash done 1 Set TFTP protocol parameter 2 Set FTP protocol parameter 3 Set XMODEM protocol parameter 0 Return to boot menu Enter your choice 0 3 After the above steps you have completed the downloading of the host software package To complete the host software upgrade you need to set the main backup attribute of the host software For ...

Страница 161: ...he boot menu BOOT MENU 1 Download application file to device 2 Select application file to boot 3 Display all files in device 4 Delete file from device 5 Modify bootrom password 0 Reboot Enter your choice 0 5 2 Select 2 and press Enter File Number File Size bytes File Name 1 4 snmpboots 2 1972 SWITCH100 cfg 3 1012 taskswitch log 4 631736 Btm105 app 5 199696 8241btm app 6 6048565 SWITCH200 app 7 563...

Страница 162: ...00 app now Yes or No Y N Y Auto booting One of the following cases may occur when the system is rebooting z The main boot file is correct and the system boots with the main boot file z An error occurs to the main boot file so the system boots with the backup boot file z An error occurs to both the main and backup files so the system randomly chooses an application file for booting z If the system ...

Страница 163: ...g cfg Flash Free Space 41804800 bytes The current application file is update app The backup boot file has not been selected Please input the file number 0 4 Enter file number 0 to select to upgrade the Boot ROM program through the host software package The system prompts you whether to upgrade the Boot ROM program through the host software package If you enter Y the system will display the followi...

Страница 164: ...es Upgrading Using FTP Run the FTP Server on the local PC assume its IP address is 10 10 110 1 Ensure that you have configured the username and password and set the correct file directory Log into the switch through Telnet or the console port and then download the host software package to the switch using FTP Assume that z The main boot file is SWITCH002 app z The active host software is SWITCH001...

Страница 165: ...ime is flash SWITCH001 app The primary app to boot of board 0 at next time is flash SWITCH002 app The slave app to boot of board 0 at next time is flash SWITCH001 app H3C reboot Make sure that other configuration is saved before rebooting the system After the above steps you have completed upgrading of the Boot ROM program and the host software Note that you must execute the reboot command to vali...

Страница 166: ...10 10 110 1 Ensure that you have configured the username and password and set the correct file directory Log into the switch through Telnet or the console port and download the host software package to the switch by using FTP 1 Download the software to the switch using FTP H3C ftp 10 10 110 1 Trying Press CTRL K to abort Connected 220 WFTPD 2 0 service by Texas Imperial Software ready for new user...

Страница 167: ...isplay boot loader The primary app to boot of board 0 at this time is flash S7502E001 app The primary app to boot of board 0 at next time is flash S7502E002 app The slave app to boot of board 0 at next time is flash S7502E001 app 4 Upgrade the Boot ROM program and host software of the standby SRPU z Copy the host software package on the active SRPU to the standby SRPU H3C copy S7502E002 app slot1 ...

Страница 168: ...itch is TFTP In this case the switch can only function as a TFTP client to download software from the TFTP server to its Flash After the downloading is completed the remaining procedure is the same as that in the case of upgrading using FTP Upgrading Through the Boot Menu You can upgrade software on the active and standby SRPUs through the boot menu in the same way Pay attention that z Two HyperTe...

Страница 169: ...process for any error If there is any input error correct it and restart the upgrade For example z If the XMODEM is used for upgrade the baud rate of the HyperTerminal is not changed back to 9600 bps after you download the software by using a baud rate other than 9600 bps z If TFTP is used for upgrade the IP address of server or switch the name of the file to be downloaded or the working path of T...

Страница 170: ...n the Terminal 7 2 Troubleshooting Power Modules 7 2 Troubleshooting the PSR320 A and the PSR320 D 7 2 Troubleshooting the PSR650 A and the PSR650 D 7 2 Troubleshooting the PSR1400 A 7 2 Troubleshooting the PSR1400 D 7 3 Troubleshooting the PSR2800 ACV 7 4 Troubleshooting the PSR6000 ACV 7 4 Troubleshooting Fans 7 5 Troubleshooting LPUs 7 5 ...

Страница 171: ...e switch is powered on and the system is normal the booting information will be displayed on the configuration terminal If the configuration system has failed the configuration terminal may display illegible characters or nothing at all No Display on the Terminal After the switch is powered on if no information is displayed on the terminal check if z The power system works normally z SRPU works no...

Страница 172: ...tails refer to related description about the power LEDs in Chapter 1 Product Overview Troubleshooting the PSR650 A and the PSR650 D Refer to section Troubleshooting the PSR650 A and the PSR650 D on page 7 2 Troubleshooting the PSR1400 A The power module PSR1400 A has three status LEDs which indicate the input and output statuses of the power module and the working status of the power module fan re...

Страница 173: ...hapter 1 Product Overview Troubleshooting the PSR1400 D The power module PSR1400 D has four LEDs which indicate the input and output statuses of the power module and the working statuses of the power module fan and the PoE power supply respectively Table 7 2 Description of LEDs on the PSR1400 D Case LED Color Status INPUT OFF The power input is normal OUTPUT OFF No power is output FAN OFF A fan do...

Страница 174: ...on the SRPUs other than the LSQ1MPUA0 in Chapter 1 Product Overview Troubleshooting the PSR2800 ACV On the right of the PSR2800 ACV power module panel are the input LED output LED fan LED PoE input LED and PoE output LED Compared with the PSR1400 A power module the PSR2800 ACV power module has two power inputs one for system power input and the other for PoE power input The meanings of the PoE pow...

Страница 175: ... is installed on the slot without a card Troubleshooting LPUs Table 7 4 Description of LPU LEDs LED Status Description ON OFF The LPU is faulty or is not installed yet RUN Green Flashing The LPU works normally OFF The LPU is faulty or is not installed yet ALM Red ON The LPU works abnormally z If the ALM LED of an LPU stays ON something is wrong with the LPU When you reset the LPU the ALM LED will ...

Страница 176: ...i Table of Contents Appendix A List of Pluggable Optical Modules A 1 XFP Modules A 1 Gigabit SFP Modules A 1 100 Mbps SFP Modules A 2 Pluggable Modules for EPON Interfaces A 3 ...

Страница 177: ...ions Maximum transmission distance 50 125µm multi mode fiber 550 m 0 34 miles SFP GE SX MM8 50 A 850 nm LC 62 5 125µm multi mode fiber 275 m 0 17 miles SFP GE LX SM13 10 A 1310 nm LC 9 125µm single mode fiber 10 km 6 21 miles SFP GE LH40 S M1310 1310 nm LC 9 125µm single mode fiber 30 km 18 64 miles SFP GE LH40 S M1550 1550 nm LC 9 125µm single mode fiber 40 km 24 86 miles SFP GE LH70 S M1550 1550...

Страница 178: ...m single mode fiber 70 km 43 50 miles SFP GE LH70 S M1610 CW 1610 nm LC 9 125µm single mode fiber 70 km 43 50 miles 100 Mbps SFP Modules Table A 3 Specifications of 100 Mbps SFP modules Type Central wavelength Connector type Cable specifications Maximum transmission distance 50 125µm multi mode fiber SFP FE SX MM1 310 A 1310 nm LC 62 5 125µm multi mode fiber 2 km 1 24 miles SFP FE LX SM13 10 A 131...

Страница 179: ...erfaces Type Central wavelength Connector type Cable specifications Maximum transmission distance SFP GE PX10 D S M1490 A 1490nm transmit 1310n m receive SC 9 125µm single mode fiber 10 km 6 21 miles SFP GE PX20 D S M1490 A 1490nm transmit 1310n m receive SC 9 125µm single mode fiber 20 km 12 43 miles ...

Страница 180: ... of Contents Appendix B AC Power Cables Used in Different Countries or Regions B 1 10A AC Power Cables Used in Different Countries or Regions B 1 16A AC Power Cables Used in Different Countries or Regions B 4 ...

Страница 181: ... regions seldom using this type of power cables I type 04041104 3m i e 9 8 ft Mainland China Connector outline Power cable outline Connector outline 1 Connec tor type Code Length Countries or regions where the type of power cables conforms to local safety regulations and can be used legally Other countries or regions using this type of power cables Countries or regions seldom using this type of po...

Страница 182: ... or regions where the type of power cables conforms to local safety regulations and can be used legally Other countries or regions using this type of power cables Countries or regions seldom using this type of power cables G type 04040890 3m i e 9 8 ft U K Malaysia Singapore Hong Kong and Egypt Connector outline Power cable outline Connector outline 4 Connect or type Code Length Countries or regio...

Страница 183: ...power cables conforms to local safety regulations and can be used legally Other countries or regions using this type of power cables Countries or regions seldom using this type of power cables I type 04040888 3m i e 9 8 ft Australia Connector outline Power cable outline Connector outline 7 Connec tor type Code Length Countries or regions where the type of power cables conforms to local safety regu...

Страница 184: ... cable outline Connector outline 9 16A AC Power Cables Used in Different Countries or Regions Table B 2 16A AC power cables used in different countries or regions Connecto r type Code Length Countries or regions where the type of power cables conforms to local safety regulations and can be used legally Other countries or regions using this type of power cables Countries or regions seldom using thi...

Страница 185: ...d Peru Philippine and A6 countries or regions Connector outline Power cable outline Connector outline 2 Connecto r type Code Length Countries or regions where the type of power cables conforms to local safety regulations and can be used legally Other countries or regions using this type of power cables Countries or regions seldom using this type of power cables F type 0404A061 3m i e 9 8 ft Hollan...

Страница 186: ...e type of power cables conforms to local safety regulations and can be used legally Other countries or regions using this type of power cables Countries or regions seldom using this type of power cables B type 0404A062 3m i e 9 8 ft Japan Connector outline Power cable outline Connector outline 5 Connecto r type Code Length Countries or regions where the type of power cables conforms to local safet...

Страница 187: ...mation C 3 Regulatory compliance standards C 3 European Directives compliance C 3 USA regulatory compliance C 3 Canada regulatory compliance C 4 Japan regulatory compliance C 4 CISPR 22 compliance C 4 Safety Information Sicherheitsinformationen安全信息 C 5 Overview Überblick 概述 C 5 Electricity Safety Elektrische Sicherheit 用电安全 C 8 Fuse Sicherung保险丝 C 12 Laser Laser激光辐射 C 13 ...

Страница 188: ...C 1 Appendix C Compliance and safety manual Regulatory compliance statement European Community CE Certification DoC Figure C 1 European Community CE Certification DoC ...

Страница 189: ...C 2 Figure C 2 European Community CE Certification DoC ...

Страница 190: ... H3C S7506E V and H3C S7510E comply with the following European Directives 89 336 EC electromagnetic compatibility 73 23 EC low voltage See Figure1 1 for H3C s Declaration of Conformity USA regulatory compliance FCC Part 15 H3C S7500E series including H3C S7502E H3C S7503E H3C S7503E S H3C S7506E H3C S7506E S H3C S7506E V and H3C S7510E comply with Part 15 of the FCC Rules Operation is subject to ...

Страница 191: ...H3C S7506E V and H3C S7510E Conform to the applicable requirements of 21 CFR Subchapter J Canada regulatory compliance ICES 003 This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada Japan regulatory compliance VCCI H3C S7500E series including H3C S7502E H3C S7503E H3C S7503E S H3C S7506E H3C S7506E S H3C S7506...

Страница 192: ...ed to the full The personnel in charge of the installation and maintenance of the products must be trained as professionals to master the proper operating methods and all safety precautions Only the trained and qualified personnel can perform operations such as equipment installation and maintenance Lesen Sie bitte alle Arbeitsanweisungen und Sicherheitvorschriften sorgfältig durch bevor Sie mit d...

Страница 193: ...erinnern 以下表格中的安全标识 是用来提示读者在进行设备安装和维护时的安全预防要求 Table C 2 Safety symbol and description Sicherheitssymbole und Beschreibung 安全标识和描述 Safety Symbol Symbole 安全标识 Description Erläuterung 描述 Generic alarm symbol To suggest a general safety concern Alarm Hinweis auf ein generelles Sicherheitsproblem 一般注意标识 用于一般安全提示 ESD protection symbol To suggest electrostatic sensitive equipment ESD Schutz Hinweis auf B...

Страница 194: ... protective earthing conductor shall be at least 1 5mm2 z Das System muss vor der ständigen Inbetriebnahme geerdet werden Der Querschnitt der Erdverbindung sollte mindestens 1 5mm betragen z 进行设备 系统操作前 请确保永久接地 并且用于进行保护接地连接的接地线截面不小于 1 5mm2 z For AC supplied model The device applies to TN power systems z Mit Wechselstrom betriebenes Modell Das Gerät arbeitet mit einem Phase Nullleiter System z AC 电源...

Страница 195: ... must be accessible at all times because it serves as the main disconnecting device z Für das angebotene DC Modell der Stromkreisbrecher muß jederzeit erreichbar sein denn er dient als Hauptabtrennungsgerät z DC 供电 空开必须随时可用 因为它是主要的切断电源装置 Electricity Safety Elektrische Sicherheit 用电安全 High Voltage Hochspannung 高电压 High voltage power supply offers electric power for equipment operation Direct contac...

Страница 196: ...halten z 当有液体进入机架或机架有损坏时 请立即切断电源 z When operation is performed in a damp environment make sure that water is kept off the equipment z Muss in einem feuchten Umgebung gearbeitet werden ist sicherzustellen dass kein Wasser in die Ausrüstung dringen kann z 在潮湿环境下进行安装时 请避免液体进入设备 Non standard and improper high voltage operations may result in fire and electric shock Therefore AC cable bridging and wiri...

Страница 197: ...achen was zu Feuer oder einer Augenverletzung führen kann 禁止安装和移动带电的线缆 因为导电体和带电的线缆 即使短暂接触 也会引起电火花或电弧 从而 导致失火或是伤害眼睛 z Before the power cable is installed or removed the power switch must be turned off z Das System muss stets abgeschaltet werden bevor die Zuleitung angebracht oder entfernt wird z 在安装 移动线缆之前 请切断电源 z Before the power cable is connected it must be confirmed that the power cable and lab...

Страница 198: ...r supply cord Für H3C S7502E H3C S7503E S Für Gleichstrom Versorgung Ausrüstung benutzen Sie bitte 4 mm2 oder 10 AWG Lehre minimale Spg Versorgungsteilschnur Für POE Eingang benutzen Sie bitte 10 mm2 oder 6 AWG Lehre minimale Spg Versorgungsteilschnur Für Wechselstrom Versorgung Ausrüstung benutzen Sie bitte 1 25 mm2 oder 16 AWG Lehre minimale Spg Versorgungsteilschnur Für H3C S7503E H3C S7506E H3...

Страница 199: ... 防雷击 High voltage and AC operations or operations on a steel tower and a mast on a thunderstorm day are prohibited Arbeiten mit Hochspannung und Wechselstrom oder Arbeiten auf Stahltürmen und masten während eines Gewitters sind verboten 禁止在雷雨天进行高压电源和 AC 交流电源安装操作 对金属架和天线的操作也是不允许的 In order to prevent the equipment from being damaged by lightning proper grounding is required Fuse Sicherung 保险丝 For th...

Страница 200: ...gehende Gefahr entspricht der Kategorie 1 本设备的激光防护等级是 1 类 When performing installation and maintenance operations of optical fibers you should not stand close to or look into the optical fiber outlet directly with unaided eyes Während der Installation und Instandhaltung der optischen Fasern dürfen Sie nicht zu nahe am Ausgang der optischen Fasern stehen und nicht ohne Augenschutz in die optischen ...

Отзывы: