Rack-mounting
23
■
The air is as free from dust as possible.
■
The unit is installed in a clean, air conditioned environment.
■
No more than eight Switch units are placed on top of one another, if
the units are free-standing.
■
The Switch is situated away from sources of conductive (electrical)
dust, for example laser printers.
■
The AC supply used by the Switch is separate to that used by units
that generate high levels of AC noise, for example air conditioning
units and laser printers.
Rack-mounting
The Switch 4400 is 1U high and will fit in most standard 19-inch racks.
CAUTION:
Disconnect all cables from the Switch before continuing.
Remove all self adhesive pads from the underside of the Switch if they
have been fitted.
To rack-mount your Switch:
1
Place the Switch the right way up on a hard flat surface, with the front
facing towards you.
2
Locate a mounting bracket over the mounting holes on one side of the
Switch, as shown in
Figure 6
.
DUA1720-3AAA03_online.book Page 23 Monday, March 25, 2002 10:48 AM
Содержание 3C17203 - SuperStack 3 Switch 4400
Страница 6: ...DUA1720 3AAA03_online book Page 6 Monday March 25 2002 10 48 AM...
Страница 52: ...52 CHAPTER 4 PROBLEM SOLVING DUA1720 3AAA03_online book Page 52 Monday March 25 2002 10 48 AM...
Страница 62: ...62 APPENDIX B PIN OUTS DUA1720 3AAA03_online book Page 62 Monday March 25 2002 10 48 AM...
Страница 66: ...66 APPENDIX C TECHNICAL SPECIFICATIONS DUA1720 3AAA03_online book Page 66 Monday March 25 2002 10 48 AM...
Страница 72: ...72 APPENDIX D TECHNICAL SUPPORT DUA1720 3AAA03_online book Page 72 Monday March 25 2002 10 48 AM...
Страница 76: ...DUA1720 3AAA03_online book Page 76 Monday March 25 2002 10 48 AM...