38
C
HAPTER
2: I
NSTALLING
T
HE
S
WITCH
7750
Connecting the
Ground Wire
To connect the ground wire:
1
Wear an antistatic wrist strap.
2
Remove the screw from the grounding hole in the switch chassis.
3
Set the ground wire connector around the grounding screw.
4
Fasten the grounding screw in the hole on the chassis.
5
Connect the other end of the ground wire to the grounding bar of the switch.
If you install the switch in a cabinet, 3Com recommends that the ground wire of
the switch be connected to the grounding bar of the cabinet.
WARNING:
The resistance between switch chassis and the ground should be less
than 1 ohm.
Connecting and
Configuring Power
The Switch 7750 requires power connection from the AC power source and from
the PoE power rack.
Connecting AC Power
Cords
To connect AC power cords:
1
Power off all the related parts of the switch before connecting the AC power cord
2
Plug the power cords into the sockets in the switch and attach the retention clips
to the power cord plugs.
3
Plug the other end of the cords into a socket strip with surge protector. Connect
the strip to the power source in the room.
Figure 28 illustrates the power cord connection.
Figure 28
Power Cord Connection
1
AC power sockets
2
Retention clips
3
Grounding screw
WARNING:
For surge protection, the power should be channelled through an
external protection device into the Switch 7750.