Configuring NBX System Networking
81
If the connection attempt fails, check the browser’s Proxy Server setting
and verify that it is configured for a direct connection. Also, check the
Connection setting and verify that it is set for a direct LAN connection,
not a dial-up connection.
After you connect, you can log in to the NBX NetSet utility using the
default administrator user name and password.
CAUTION:
If you change the administrator password, you cannot retrieve
(return) to the default, nor can you retrieve your new password if you
forget it. If you make any password changes, record them in a safe place.
Table 10
describes possible network environments and the configuration
needed to enable IP connectivity to the NBX system.
Table 10
IP Addressing and the NBX System
Local IP Environment
NBX System Configuration
No IP networking currently in
use
You do not need to change the IP settings in the NBX system, but you probably
need to configure the IP settings in the computer that you use to communicate
with the NBX NetSet utility.
The computer must have an Ethernet NIC card, IP connectivity software installed
and configured, and a web browser. See the computer’s operating system
documentation for how to install and configure IP connectivity software.
Set the computer’s IP parameters to these settings:
■
IP address: 192.168.1.191
■
Default gateway: 192.168.1.1
■
Subnet mask: 255.255.255.224
If you connect the LAN to the Internet in the future, your Internet service provider
gives instructions on how to configure the IP settings of devices on the network.
You must change the IP settings of the NBX system at that time.
CAUTION:
Do not set your computer address to 192.168.1.19
2
because this IP address is used
temporarily during system startup. If you use that address for your computer, a conflict results and
the system may not start properly.
Private IP network, no subnets
You probably need to change the NBX system IP address to conform with the
existing IP addressing scheme.
You must change the NBX system IP address (192.168.1.190) if that address is
already in use on the network.
Содержание 3C10111C - NBX 100 - Modular Exp Base
Страница 20: ...20 ABOUT THIS GUIDE ...
Страница 102: ...102 CHAPTER 2 INSTALLING SYSTEM HARDWARE COMPONENTS ...
Страница 122: ...122 CHAPTER 4 ANALOG LINE CARDS ...
Страница 132: ...132 CHAPTER 5 ANALOG DEVICES ...
Страница 138: ...138 CHAPTER 6 BRI ST DIGITAL LINE CARD ...
Страница 144: ...144 CHAPTER 7 E1 ISDN PRI DIGITAL LINE CARD ...
Страница 150: ...150 CHAPTER 8 T1 DIGITAL LINE CARD ...
Страница 184: ...184 APPENDIX A SPECIFICATIONS ...
Страница 190: ...190 APPENDIX B CIRCUIT PROVISIONING ...
Страница 206: ...206 INDEX ...