System Configuration Guidelines
49
■
You want to configure 200 Attendant Consoles, but, because the
individual device limit for Attendant Consoles is 100, you can
configure only 100 of them.
The total device count is now 622. You can configure 128 additional
devices (750–622).
■
You want to add Virtual Tie Lines (VTLs), but you can add only 48
because that is the maximum license level available for VTLs.
Because VTLs do not count toward the device limit, the total device
count remains at 622. So, after you add 48 VTLs, you can still
configure up to 128 additional devices.
Table of Maximum
Device Counts
Table 5
lists each NBX device and application, with information on
whether it counts toward the total device count and the maximum
number allowed per NBX system.
For the current device and license configuration on your system, see
NBX NetSet > Operations > Licenses
as well as the
Usage Report
accessible from the Licenses screen. See the 3Com Price List or your
3Com NBX Voice-Authorized Partner for details on incremental licences.
Table 5
Supported Features on the SuperStack 3 NBX and NBX 100 Call Processors
Per-Unit Device Count
Toward Total System
Count
Maximum Number
Per SuperStack 3
System
Maximum. Number
Per NBX 100 System
System Device Capacity
3Com Business Telephone
1
1500
200
3Com Basic Telephone
1
1500
200
3Com Attendant Console
1
100
50
pcXset Soft Telephone
1 per pcXset PC telephone
client
1500
200
NBX Media Driver (for WAV
devices)
1 driver per system enables
the maximum allowable
number of WAV devices
1500
200
Polycom IP 3000 Speaker Phone
1
93 cards (1488 ports)
12 cards (192 channels)
CITELlink Handset Gateway card
16 per card
1500
200
NBX Analog Terminal Card (ATC) 4 per card
375 cards (1500 ports)
50 cards (200 ports)
CAUTION: SuperStack 3 NBX:
If you are using the 3Com SuperStack II ARPS
(Advanced Redundant Power Supply) as a backup power supply for the NBX
Gateway Chassis, you are limited to two ATC cards of version 3C10117 or
3C10117B per NBX Gateway Chassis. (3C10117C is not restricted in this way.)
Содержание 3C10111C - NBX 100 - Modular Exp Base
Страница 20: ...20 ABOUT THIS GUIDE ...
Страница 102: ...102 CHAPTER 2 INSTALLING SYSTEM HARDWARE COMPONENTS ...
Страница 122: ...122 CHAPTER 4 ANALOG LINE CARDS ...
Страница 132: ...132 CHAPTER 5 ANALOG DEVICES ...
Страница 138: ...138 CHAPTER 6 BRI ST DIGITAL LINE CARD ...
Страница 144: ...144 CHAPTER 7 E1 ISDN PRI DIGITAL LINE CARD ...
Страница 150: ...150 CHAPTER 8 T1 DIGITAL LINE CARD ...
Страница 184: ...184 APPENDIX A SPECIFICATIONS ...
Страница 190: ...190 APPENDIX B CIRCUIT PROVISIONING ...
Страница 206: ...206 INDEX ...