background image

Copyright ©2019 by 3Built LLC 

9/30/19 

Firmware ver:6.1.19 

DEFINITIONS 

OEM

 - Original Equipment Manufacturer.  This is any component that the vehicle originally came equipped with from the 

factory. 

RES

 - 3Built’s Remote Engine Shut-off kits 

Normally-open

 - means that the switch is open (no connection) when the RES is in the unlocked mode.  This connection type is 

typically used for ground type OEM RUN/STOP switches. 

Normally-closed

 - means that the switch is closed (connected) when the RES is in the unlocked mode.  This connection type is 

typically used on positive voltage type OEM Run/Stop switches. 
 

INSTALLATION

 

1)

 

 Charge the 

Transmitter

 by plugging it in to a USB charger (5 volts).  The cable is a USB to mini-USB. With the power switch off, 

you will see a small red or blue light towards the bottom of the 

Transmitter

 (small window) while charging.  The included lithium 

battery is designed for hundreds of charge cycles. It can be replaced, if necessary, with another lithium-ion 18500 size battery. 

Blue LED = fully charged ;  Red LED = charging 

2)

 

 Find a suitable place to mount the 

Receiver

.  Position it so that it will stay dry and will not be damaged in case of an accident.  

3)

 

 Attach the Red Wire on the 

Receiver 

to 12 volts DC power supply.  We recommend that you use a fuse if connecting directly to a 

battery or un-fused power wire. Improperly mounted wires can become damaged and short to the frame causing damage to the 
vehicle and/or driver.  Damage may include high heat and/or fire. 

4)

 

 Attach the Black Wire to ground. 

5)

 

 Choose either Normally Open or Normally Closed connection type.

 

      

 

a.

 

Normally Closed Connection for Relay (8-amp max.) [diagram #1] (Default state)

 

 

Typical for MSD 6, MSD 7, and MSD Pro Mag 44  

This is used typically when an ignition system needs to be powered from the battery. It is very important to cut the correct 
wire for proper operation.  Incorrect wiring can damage the CDI or other electrical component.  Use caution and consult a 
professional if unsure. 
Blue Wire – Identify the power wire from the OEM Run/Stop switch to the CDI.  Cut the wire and attach the 

Blue Wire

 to 

one end of the cut wire 
Green Wire – Attach the 

Green Wire 

to the other end of the previously cut wire. It does not matter which wire is attached 

to which side of the cut wire.   

b.

 

Normally Open Connection for Relay (8-amp max.) [diagram #1]

 

 

Typical for MSD Pro Mag 12

 

***Must perform “NORMALLY-OPEN MODE” steps in PROGRAMMING section.  *** 

This is typically used when an ignition system must be grounded to shut off the vehicle. 
Blue Wire – The wire will be attached to the vehicle’s electrical system. The OEM RUN/STOP switch has two wires.  One 
comes from the CDI and the other goes to the vehicle’s ground.  Splice the Blue Wire between the CDI and the OEM 
Run/Stop switch.  Attaching the Blue Wire to an incorrect wire may damage the CDI or other electrical component.  Use 
caution and consult a professional if unsure.   

 

RECEIVER 

 

1)

 

Flip the POWER switch on the side of the 

Receiver

.   

a)

 

The Yellow LED will illuminate and the Red or Green LED will blink three time rapidly. 
i)

 

Red blinks indicate 

Receiver

 is in Normally Closed operation (default) 

ii)

 

Green blinks indicate 

Receiver

 is in Normally Open operation 

b)

 

After the startup blinks, the system will settle on one of three colors 
i)

 

Blue

 – System is in Team mode.  Only 

Team

 

Transmitters

 will activate the 

Receiver

Содержание RES12VLAB

Страница 1: ...d to be installed and used by adults only This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation INCLUDED PARTS 1 Receiver 1 Transmitter 1 USB Cable 1 USB Charger Lane Power Switch Switch ...

Страница 2: ... connection type a Normally Closed Connection for Relay 8 amp max diagram 1 Default state Typical for MSD 6 MSD 7 and MSD Pro Mag 44 This is used typically when an ignition system needs to be powered from the battery It is very important to cut the correct wire for proper operation Incorrect wiring can damage the CDI or other electrical component Use caution and consult a professional if unsure Bl...

Страница 3: ...ellow LED Transmitter CANNOT CONNECT to the Receiver i Either the receiver is turned off Check on off switch on Receiver or check the connection and ensure black and red wire are connected to the 12 volt battery ii or the receiver is out of range Move closer and press either the run button or off button until you receive a solid Green or Red light Once the light turns from yellow to either solid r...

Страница 4: ...RED Transmitter button for at least 15 seconds 7 The Receiver s LEDs will blink to indicate mode change 8 Release the red button on the Transmitter 9 Perform Step 1 in this section to confirm desired mode STATUS CHECK MODIFICATION Transmitter asks the receiver if it is in off or run mode every 30 seconds This can be disabled if desired 1 Turn Receiver and Transmitter off 2 Press and hold the green...

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Отзывы: