The INV-XALARM-PSU has eight normally open/closed (Dilswitch S1, switch 8 on) alarm inputs on connector CON1
on the alarm PCB, When using normally closed contacts, all unused alarm inputs musty be connected to the alarm in
common CON 1. Connect switches or volts free relay outputs from PIRs or other equipment to CON1 connector is
activated. There is also an alarm relay which can be used to activate alarm s on other equipment (DVR etc) The
Alarm relay contacts (Common - 'C'. Normally Open - 'NO' are Normally Close - 'NC') use connector CON3 on the
alarm PCB.
When an alarm is activated, the ALARM PCB will activate the alarm relay output and will send commands to set the
lnvictus to activate 'alarm mode'. The lnvictus will save the current status (pan, tilts, lens, tour and mimic) then it will
seek the preset which corresponds with the active alarm number.
Alarm Number
Preset Number
Alarm Number
Preset Number
1
1
5
5
2
2
6
6
3
3
7
7
4
4
8
8
The alarm will remain active while the alarm input is active. After the alarm input becomes inactive, a 10 second
alarm timer will start. The timer extends the alarm activity until the alarm timer expired. If the alarm input becomes
active again before the timer has expired, the timer resets and will restarts again when the alarm input comes
inactive and a further preset seek command is sent to the lnvictus
If an alarm is active and a further alarm becomes active, the latest alarm will interrupt the previous alarm. (I.e. the
latest alarm as highest priority) The lnvictus will seek the preset that corresponds with the new alarm. When contact
become inactive, the lnvictus will seek the preset that corresponds with the previous highest priority alarm that is still
active. When all alarms inputs are inactive the alarm timer starts. After the timer expires, the Alarm PCB sends a
commands to the lnvictus to end the 'alarm mode' and the lnvictus will return to the status position and action that
has been saved when first alarm became active (Fit a link on the alarm card COM4 position 7 to disable the
automatic return to the pre· alarm status when all alarms and the alarm time have expired)
When an alarm is active and the lnvictus has automatically selected the appropriate preset, it is possible
to send further commands (i.e. Manual control) to the lnvictus which will override the preset which had
previously been automatically selected. Each time an automatic preset seek occurs as described in the
previous paragraph; the manual control will be interrupted.
4.1 Standalone Alarmcard Setup
1
-..e::::�:::::::=�fl1h��---:===--l-i-
-l-
Protocol/Alarm settings
Use CON4 to set protocol and camera
alarm behavior
(see page 9)
Power Connections
Connect Power 30Vdc to CON7
RS485 Out Connections/LK1 termination
Connect RS485 to camera to CON5
Relay Output
Use CON3 for relay output.
Alarm Inputs
Use CON 1 for volt free alarm inputs
Address (1-7) (Range 1 to 128)
Use Dilswitch to set address same as camera.
(See Page 8)
Alarm Input setting
Use Dilswich pole 8 to set if alarms are N/0 or N/C. All
unused N/C contacts to be connected to alarm common.
(See Page 8)
RS485 In Connections/LK3 termination
Connect RS485 from controller to CON6
V12_1_129_03
Page 7 of 49
© 360 Vision Technology Ltd
Содержание Invictus Hybrid
Страница 1: ...V12_1_129_03 Page 1 of 49 360 Vision Technology Ltd ...
Страница 8: ...V12_1_129_03 Page 8 of 49 360 Vision Technology Ltd ...
Страница 9: ...V12_1_129_03 Page 9 of 49 360 Vision Technology Ltd ...
Страница 16: ...V12_1_129_03 Page 16 of 49 360 Vision Technology Ltd ...
Страница 24: ...V12_1_129_03 Page 24 of 49 360 Vision Technology Ltd ...
Страница 27: ...V12_1_129_03 Page 27 of 49 360 Vision Technology Ltd ...
Страница 44: ...V12_1_129_03 Page 44 of 49 360 Vision Technology Ltd ...
Страница 45: ...V12_1_129_03 Page 45 of 49 360 Vision Technology Ltd ...
Страница 49: ...V12_1_129_03 Page 49 of 49 360 Vision Technology Ltd ...