![360 Vision Centurion Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/360-vision/centurion/centurion_installation-and-configuration-manual_440281013.webp)
Centurion Installation Manual Ver 2.7
Page 13
© 360 Vision Technology Ltd.
5 Connections to Centurions with HMA
When the HMA (Hinged Mount Adaptor) is fitted to the Centurion, the ‘Centurion Composite Cable’ is not used.
Connections between the power supply and Centurion use conventional cables as detailed below.
30Vdc Power connections between Centurion PSU and Centurion that is fitted with
HMA
Cable Size
No IR
IR80
IR110WL
0.75mm²
85m
32m
32m
1.00mm²
113m
43m
43m
1.25mm²
141m
54m
54m
1.50mm²
170m
65m
65m
2.50mm²
283m
108m
108m
3.00mm²
340m
130m
130m
4.00mm²
450m
173m
173m
Gain access to connectors in the HMA
•
Ensure that the fixed part of the HMA is securely bolted to the top of the pole.
•
The hinged part of the HMA (Hinged Mount Adapter) is fastened to the fixed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is fitted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
fibre washer) and a fibre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.
• Open the hinge taking care that the gasket is not damaged and support the weight of the Centurion.
Gently open the HMA until the lanyard is able to take the weight. If the lanyard appears to support the
weight of the Centurion, there is no need to continue to support the Centurion. The connection circuit
board (PCB-000-0221-xx) can now be seen.
Camera
Use BNC Video 1 for video connection from Centurion.
Power Connections
Connect 24Vac/30vdc to CON5.
RS485 Connections
Connect RS485/Twisted Pair data cable to CON2.
Please make sure there is adequate spare cable (20cm) for when the camera is resting on the lanyard, failure
to do this could damage the connector circuit board.