Page 52
MAXX-2400HD Owner’s Manual
Programming GPIO Outputs
The MAXX-2400HD has twelve General Purpose Outputs, referred to as GPO 1 through 12. Each
can be programmed to go active on the selected channel when one of the following events occurs:
IDLE
Transport returns to idle
PAUSED
Transport is paused
STOPPED
Transport is stopped
PLAYING
Transport is playing
RECORDING
Transport is recording
RAID System Fault
RAID or System Fault
NO GENLOCK
No genlock
NO VIDEO INPUT
No video at the selected input
PLAYLIST
Control GPO via playlist
To program a GPO output, select
EDIT->CONFIGURE->GPO.
The screen of Figure 16 is
displayed. GPO 1 through 12 are triggerable outputs. The checkboxes to the right of each selection
represent channel 1, 2, 3 and 4. GPO 9 is shown with the trigger option pulldown expanded.
1.
To activate one of the GPO, pulldown the event menu and select which event will activate
the GPO.
2.
Select an associated channel where applicable by checking the channel checkbox.
3.
Click
APPLY
to activate.
Figure 16 - GPO Configuration Screen