18
•
The air curtain must be pRotected by an appropriate circuit breaker, in accordance with its electrical
parameters. For safety reasons, over-designed protection is not recommended.
•
The air curtain must be connected using the TN-S system, which means that the neutral conductor
must always be connected.
•
A main cut-off switch must be placed in the electrical supply network, disconnecting all poles of the
network.
•
The electrical enclosure of the air curtain is IP 20.
FINESSE air curtains are equipped with a fuse (with T characteristic – slow-blow). This safety fuse pRo-
tects the electronic panel and fans. It is located under the service cover next to the main power supply
connectors.
6. 5 CONTROL MODULES
Air curtains FINESSE are produced with universal connection interface.
Air curtains FINESSE can be controlled by one of following control modules: BASIC, COMFORT,
SUPERIOR.
Control modules are required accessories and has to be orderot separatelly.
Air curtain is connected with control module by „Quick connection sockets“
•
The electrical parameters are shown
on the manufacturer‘s label, which is
located under the air curtain‘s service
cover.
6. INSTALLATION
Содержание FINESSE
Страница 1: ...INSTALLATION EN FINESSE ...
Страница 19: ...19 6 6 INSERT CONTROL MODULETOTHE AIR CURTAIN 6 INSTALLATION 2 1 ...
Страница 24: ...24 10 ELECTRICAL SCHEMES Types without heating VCF B xxx S VCF B 100 VCF B 150 VCF B 200 VCF B 250 Fuse Fuse ...
Страница 26: ...26 Types with electric heaterVCF B xxx E VCF B 100 E VCF B 150 E 10 ELECTRICAL SCHEMES Fuse Fuse Fuse ...
Страница 27: ...27 VCF B 200 E VCF B 250 E 10 ELECTRICAL SCHEMES Fuse Fuse ...
Страница 30: ...30 10 ELECTRICAL SCHEMES VCF C 100 E VCF C 150 E Types with electric heaterVCF C xxx E Fuse Fuse ...
Страница 31: ...31 VCF C 200 E VCF C 250 E 10 ELECTRICAL SCHEMES Fuse Fuse ...