Setting the mini-
mum temperature
that allows to open
the bypass (0-20°C)
MENU 10 - SUPPLY DUCT LIMITS
Set minimum canal
temperature
Set maximum canal
temperature
Enable or disable the unit's rate
reduction if canal minimum is not
reached (enabled by default)
Due to possible condensation on the surface of the ventilation duc-
twork, it is recommended to leave enabled the reduction of flow if
canal minimum is not reached.
MENU 11 - BYPASS TEMPERATURE
MENU 12 - FLOW OFFSET
Set positive
or negative
pressure
MENU 13 - FIREFLOW
Setting the unit's
rate when the FIRE
contact opens
(input terminals
15/16)
The FIRE FLOW and OCCUPANCY modes can not be
used simultaneously One of the modes must be chosen in
the HW setting menu
Selecting the sensor in the supply ductwork disables
the maximum temperature setting in the ductwork
The FIRE input has the highest priority (it dis-
ables all the other modes, including anti-freeze
protection)
10 - Supply Duct Limits
11 - Bypass Temperature
12 - Flow Offset
09 - Temperature sensor
08 - AQS Sensor
11 - Bypass Temperature
10 - Supply Duct Limits
09 - Temperature sensor
12 - Flow Offset
13 - Fire Flow
12 - Flow Offset
11 - Bypass Temperature
10 - Supply Duct Limits
13 - Fire Flow
14 - Occupancy
13 - Fire Flow
14 - Occupancy
15 - Boost
11 - Bypass Temperature
12 - Flow Offset