15
2VV.
Creating innovative solutions for you and your business since 1995.
ver.1 19-07-21
conditions for activation Selflearning mode.
1. Fan power while open door
2. The temperature which the heater attempts to reach
while open door.
2
1
In this menu it is possible to specify which sensor will be
active and the temperature the air curtain attempt to reach
after closing doors so as to balance temperature loss.
After reaching the set temperature, the air curtain returns
into the selected automatic/manual mode.
Temperature overrun mode setting
08
30
1. Enable/disable function
2. required temperature with the door open.
2
1
Selflearning- available only in automation and active
function mode (Auto speed control), depending on the
number of open doors it optimises the period in which the
shutter is in operation, even when doors are closed.
Door contact -
Selflearning